Prospective clinical and radiostereometric analysis of the Fitmore short-stem total hip arthroplasty

被引:31
|
作者
Acklin, Yves P. [1 ]
Jenni, Raphael [1 ]
Bereiter, Heinz [1 ]
Thalmann, Caroline [1 ]
Stoffel, Karl [2 ]
机构
[1] Kantonsspital Graubunden, Orthoped Surg, Loestr 99, CH-7000 Chur, Switzerland
[2] Kantonsspital Baselland, Orthoped Surg, Rheinstr 26, Liestal, Switzerland
关键词
RSA; Fitmore; Stem migration; Short stem; PRIMARY STABILITY; FEMORAL PROSTHESIS; MIGRATION PATTERN; EBRA-FCA; IMPLANTS; RSA; REPLACEMENT; MICROMOTION; SURVIVAL; REVISION;
D O I
10.1007/s00402-015-2401-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Uncemented short, curved femoral stems may help save proximal bone stock during total hip arthroplasty (THA) and facilitate insertion in minimal invasive surgery. The aim of this 2 year, prospective, single-center study was to examine the stability and migration of the Fitmore (A (R)) stem in THA using model-based radiostereometric analysis (RSA), and thus predict the implant's long-term survival. In addition, we evaluated the stem's clinical performance using standard clinical measures. We conducted a prospective cohort study of 34 THA patients who received the short Fitmore Hip Stem (Zimmer, Winterthur, Switzerland). At 3, 6, 12 and 24 months postoperatively, the patients underwent clinical evaluation and radiostereometric analysis (RSA) to measure stem migration. RSA analysis revealed a mean subsidence of -0.39 mm (95 % CI -0.60 to -0.18) at 3 months with no further migration after 2 years. Mean internal rotation along the longitudinal axis was 1.09A degrees (95 % CI 0.52-1.66) at 2 years, versus 0.85A degrees (95 % CI 0.44-1.26) at 3 months. The Harris hip score improved from 60 (range 30-80) preoperatively to 99 (range 83-100) after 2 years. Three patients underwent revision due to deep infection, non-specific thigh pain and aseptic loosening in one case. We conclude that the Fitmore Hip Stem stabilizes after 3 months and achieves good short-term clinical results in most cases.
引用
收藏
页码:277 / 284
页数:8
相关论文
共 50 条
  • [1] Prospective clinical and radiostereometric analysis of the Fitmore short-stem total hip arthroplasty
    Yves P. Acklin
    Raphael Jenni
    Heinz Bereiter
    Caroline Thalmann
    Karl Stoffel
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 277 - 284
  • [2] Prospective clinical and radiographic 10-year results of Fitmore short-stem total hip arthroplasty
    Schader, Jana Felicitas
    Thalmann, Caroline
    Maier, Katharina Sophia
    Schiener, Tom
    Stoffel, Karl
    Frigg, Arno
    SWISS MEDICAL WEEKLY, 2023, 153 : 76S - 76S
  • [3] Prospective evaluation of clinical and radiographic 10-year results of Fitmore short-stem total hip arthroplasty
    Jana F. Schader
    Caroline Thalmann
    Katharina S. Maier
    Tom Schiener
    Karl Stoffel
    Arno Frigg
    Journal of Orthopaedic Surgery and Research, 18
  • [4] Prospective evaluation of clinical and radiographic 10-year results of Fitmore short-stem total hip arthroplasty
    Schader, Jana F.
    Thalmann, Caroline
    Maier, Katharina S.
    Schiener, Tom
    Stoffel, Karl
    Frigg, Arno
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [5] Short stems for total hip arthroplasty INITIAL EXPERIENCE WITH THE FITMORE™ STEM
    Gustke, K.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11): : 47 - 51
  • [6] Osseointegration of Fitmore Stem in Total Hip Arthroplasty
    Gasbarra, Elena
    Celi, Monica
    Perrone, Fabio L.
    Iundusi, Riccardo
    Di Primio, Luigia
    Guglielmi, Giuseppe
    Tarantino, Umberto
    JOURNAL OF CLINICAL DENSITOMETRY, 2014, 17 (02) : 307 - 313
  • [7] Return to Sport After Short-Stem Total Hip Arthroplasty
    Ortmaier, Reinhold
    Pichler, Hannes
    Hitzl, Wolfgang
    Emmanuel, Katja
    Mattiassich, Georg
    Plachel, Fabian
    Hochreiter, Josef
    CLINICAL JOURNAL OF SPORT MEDICINE, 2019, 29 (06): : 451 - 458
  • [8] The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty
    Schmidutz, Florian
    Steinbrueck, Arnd
    Wanke-Jellinek, Lorenz
    Pietschmann, Matthias
    Jansson, Volkmar
    Fottner, Andreas
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1767 - 1772
  • [9] The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty
    Florian Schmidutz
    Arnd Steinbrück
    Lorenz Wanke-Jellinek
    Matthias Pietschmann
    Volkmar Jansson
    Andreas Fottner
    International Orthopaedics, 2012, 36 : 1767 - 1772
  • [10] Radiological short term results after total hip arthroplasty using the Fitmore® hip stem
    Wanner, Ronald
    Notzli, Hubert
    Wyss, Tobias
    Miozzari, Hermes
    SWISS MEDICAL WEEKLY, 2013, 143 : 30S - 30S