Nafion covered lead film electrode for the voltammetric determination of caffeine in beverage samples and pharmaceutical formulations

被引:29
|
作者
Tyszczuk-Rotko, Katarzyna [1 ]
Beczkowska, Ilona [1 ]
机构
[1] Marie Curie Sklodowska Univ, Fac Chem, PL-20031 Lublin, Poland
关键词
Nafion film; Lead film electrode; Adsorptive stripping voltammetry; Caffeine; STRIPPING VOLTAMMETRY; SOFT DRINKS; THEOBROMINE; SENSOR; COFFEE; ACID;
D O I
10.1016/j.foodchem.2014.09.056
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
This paper presents a sensitive, selective and low-cost voltammetric method for the determination of caffeine using a Nafion covered lead film electrode. The sensor was prepared on a glassy carbon electrode modified with lead film recovered by a Nafion layer. Caffeine was accumulated and then oxidised at the modified electrode surface to produce two anodic peaks at 0.86 and 1.40 V (vs. Ag/AgCl) in 0.1 mol L-1 H2SO4 medium. The obtained detection limits for caffeine following 120 s of accumulation time were equal to 1.7 x 10(-8) mol L-1 (for peak 1) and 2.2 x 10(-7) mol L-1 (for peak 2). The method was successfully applied to determination of caffeine in tea, coffee, soft and energy drink samples as well as pharmaceutical formulation and the contents closely corresponded to those quoted by the manufacturer and those obtained by the reported spectrophotometric method. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [1] Voltammetric determination of caffeine in beverage samples on bare boron-doped diamond electrode
    Svorc, Lubomir
    Tomcik, Peter
    Svitkova, Jana
    Rievaj, Miroslav
    Bustin, Dusan
    FOOD CHEMISTRY, 2012, 135 (03) : 1198 - 1204
  • [2] Graphene/Nafion composite film modified glassy carbon electrode for simultaneous determination of paracetamol, aspirin and caffeine in pharmaceutical formulations
    Yigit, Aydin
    Yardim, Yavuz
    Celebi, Metin
    Levent, Abdulkadir
    Senturk, Zuhre
    TALANTA, 2016, 158 : 21 - 29
  • [3] Determination of caffeine at a Nafion-covered glassy carbon electrode
    Brunetti, Barbara
    Desimoni, Elio
    Casati, Paolo
    ELECTROANALYSIS, 2007, 19 (2-3) : 385 - 388
  • [4] Voltammetric determination of platinum at a lead film electrode in environmental water samples
    Tyszczuk-Rotko, Katarzyna
    Rotko, Marek
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2014, 186 (11) : 7801 - 7806
  • [5] Voltammetric determination of platinum at a lead film electrode in environmental water samples
    Katarzyna Tyszczuk-Rotko
    Marek Rotko
    Environmental Monitoring and Assessment, 2014, 186 : 7801 - 7806
  • [6] Voltammetric Determination of Diazepam on Antimony Film Screen-Printed Electrode in Pharmaceutical Formulations
    Antunovic, Vesna
    Baosic, Rada
    Lolic, Aleksandar
    CURRENT PHARMACEUTICAL ANALYSIS, 2021, 17 (07) : 945 - 950
  • [7] Simultaneous voltammetric determination of paracetamol and caffeine in pharmaceutical formulations using a boron-doped diamond electrode
    Lourencao, Bruna Claudia
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Mazo, Luiz Henrique
    Fatibello-Filho, Orlando
    TALANTA, 2009, 78 (03) : 748 - 752
  • [8] Voltammetric determination of mixtures of caffeine and chlorogenic acid in beverage samples using a boron-doped diamond electrode
    Yardim, Yavuz
    Keskin, Ertugrul
    Senturk, Zuhre
    TALANTA, 2013, 116 : 1010 - 1017
  • [9] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    Yu, Lanlan
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1371 - 1378
  • [10] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Suling Yang
    Lingbo Qu
    Ran Yang
    Jianjun Li
    Lanlan Yu
    Journal of Applied Electrochemistry, 2010, 40 : 1371 - 1378