Inductively Coupled Plasma Zoom-Time-of-Flight Mass Spectrometry

被引:3
|
作者
Dennis, Elise A. [1 ]
Ray, Steven J. [1 ]
Enke, Christie G. [2 ]
Hieftje, Gary M. [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
[2] Univ New Mexico, Dept Chem & Biol Chem, Albuquerque, NM 87131 USA
关键词
Inductively coupled plasma; Zoom-TOF; Time-of-Flight; Mass spectrometry; CONSTANT-MOMENTUM-ACCELERATION; LASER-ABLATION; ELECTROTHERMAL VAPORIZATION; SAMPLE INTRODUCTION; PERFORMANCE; RESOLUTION; ENERGY; SPECIATION; CYTOMETRY; DETECTOR;
D O I
10.1007/s13361-015-1309-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A zoom-time-of-flight mass spectrometer has been coupled to an inductively coupled plasma (ICP) ionization source. Zoom-time-of-flight mass spectrometry (zoom-TOFMS) combines two complementary types of velocity-based mass separation. Specifically, zoom-TOFMS alternates between conventional, constant-energy acceleration (CEA) TOFMS and energy-focused, constant-momentum acceleration (CMA) (zoom) TOFMS. The CMA mode provides a mass-resolution enhancement of 1.5-1.7x over CEA-TOFMS in the current, 35-cm ICP-zoom-TOFMS instrument geometry. The maximum resolving power (full-width at half-maximum) for the ICP-zoom-TOFMS instrument is 1200 for CEA-TOFMS and 1900 for CMA-TOFMS. The CMA mode yields detection limits of between 0.02 and 0.8 ppt, depending upon the repetition rate and integration time-compared with single ppt detection limits for CEA-TOFMS. Isotope-ratio precision is shot-noise limited at approximately 0.2% relative-standard deviation (RSD) for both CEA- and CMA-TOFMS at a 10 kHz repetition rate and an integration time of 3-5 min. When the repetition rate is increased to 43.5 kHz for CMA, the shot-noise limited, zoom-mode isotope-ratio precision is improved to 0.09% RSD for the same integration time.
引用
收藏
页码:380 / 387
页数:8
相关论文
共 50 条
  • [1] Mass analyzers for inductively coupled plasma time-of-flight mass spectrometry
    Ray, S.J.
    Hieftje, G.M.
    1600, Royal Society of Chemistry (16):
  • [2] Mass analyzers for inductively coupled plasma time-of-flight mass spectrometry
    Ray, SJ
    Hieftje, GM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (10) : 1206 - 1216
  • [3] Capabilities of laser ablation inductively coupled plasma time-of-flight mass spectrometry
    Burger, Marcel
    Schwarz, Gunnar
    Gundlach-Graham, Alexander
    Kaser, Debora
    Hattendorf, Bodo
    Guenther, Detlef
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (10) : 1946 - 1959
  • [4] Inductively coupled plasma time of flight mass spectrometry for trace element and speciation analysis
    Emteborg, H
    Tian, XD
    Heisterkamp, M
    Adams, FC
    TRACE ELEMENTS IN MAN AND ANIMALS 10, 2000, : 1107 - 1110
  • [5] In torch laser ablation sampling for inductively coupled plasma time of flight mass spectrometry
    Tanner, Martin
    Guenther, Detlef
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (09) : 941 - 947
  • [6] Laser ablation-inductively coupled plasma mass spectrometry with a time-of-flight mass analyser
    Mahoney, PP
    Li, GQ
    Hieftje, GM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (06) : 401 - 405
  • [7] Inductively coupled plasma mass spectrometry
    Beauchemin, D
    ANALYTICAL CHEMISTRY, 2004, 76 (12) : 3395 - 3415
  • [8] Inductively coupled plasma mass spectrometry
    Woeste, S
    LABORATORY MEDICINE, 2004, 35 (02) : 73 - 75
  • [9] Inductively coupled plasma mass spectrometry
    Beauchemin, Diane
    ANALYTICAL CHEMISTRY, 2006, 78 (12) : 4111 - 4135
  • [10] Inductively coupled plasma mass spectrometry
    Van Acker, Thibaut
    Theiner, Sarah
    Bolea-Fernandez, Eduardo
    Vanhaecke, Frank
    Koellensperger, Gunda
    NATURE REVIEWS METHODS PRIMERS, 2023, 3 (01):