Maxillary molar distalization with the dual-force distalizer supported by mini-implants: A clinical study

被引:0
|
作者
Oberti, Giovanni [2 ]
Villegas, Carlos [3 ]
Ealo, Martha
Palacio, John Camilo
Baccetti, Tiziano [1 ]
机构
[1] Univ Florence, Dept Orthodont, I-50127 Florence, Italy
[2] CES Univ, Dept Orthodont, Medellin, Colombia
[3] CES Univ, Dept Orthodont & Maxillofacial Surg, Medellin, Colombia
关键词
PENDULUM APPLIANCE; SKELETAL CHANGES; MOVEMENT; ANCHORAGE; MAGNETS; 2ND;
D O I
10.1016/j.ajodo.2007.10.039
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The objective of this prospective study was to describe the clinical effects of a bone-supported molar distalizing appliance, the dual-force distalizer. Methods: The study group included 16 patients (mean age, 14.3 years) with Class II molar relationships. Study models and lateral cephalograms were taken before and after the distalizing movement to record significant dental and skeletal changes (Wilcoxon test). Results: The average distalization time was 5 months, with a movement rate of 1.2 mm per month; the distalization amounts were 5.9 +/- 1.72 mm at the crown level and 4.4 +/- 1.41 mm at the furcation level. The average molar inclination was 5.6 degrees +/- 3.7 degrees; this was less than the amount of inclination generated by bone-supported appliances that use single distalizing forces. The correlation between inclination and distalization was not significant, indicating predominantly bodily movement. The teeth anterior to the first molar moved distally also; the second premolars distalized an average of 4.26 mm, and the incisors retruded by 0.53 mm. Conclusions: The dual-force distalizer is a valid alternative distalizing appliance that generates controlled molar distalization with a good rate of movement and no loss of anchorage. (Am J Orthod Dentofacial Orthop 2009; 135: 282.e1-282.e5)
引用
收藏
页码:282.e1 / 282.e5
页数:7
相关论文
共 50 条
  • [1] Maxillary molar distalization treated with clear aligners combined with mini-implants and angel button using different traction force: a finite element study
    Cui, Jiayu
    Yao, Chengliang
    Zhang, Zheyuan
    Zhang, Tong
    Cao, Yuxin
    Liu, Ting
    Li, Bing
    Wu, Xiuping
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (03) : 296 - 305
  • [2] The efficiency of molar distalization using clear aligners and mini-implants: Two clinical cases
    Auladell, Anna
    De La Iglesia, Fernando
    Quevedo, Oriol
    Walter, Andre
    Puigdollers, Andreu
    INTERNATIONAL ORTHODONTICS, 2022, 20 (01)
  • [3] Maxillary molar mesialization with palatal mini-implants response
    Wilmes, Benedict
    Vasudavan, Sivabalan
    Drescher, Dieter
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2020, 157 (01) : 4 - 4
  • [4] Maxillary Molar Intrusion: Mini-Implants vs. Corticotomy
    Wu, Y. -Y.
    INFORMATIONEN AUS ORTHODONTIE UND KIEFERORTHOPAEDIE, 2014, 46 (03): : 209 - 212
  • [5] Non-Compliance Distalization Appliances Supported by Mini-Implants: A Systematic Review
    Karvelas, Nikolaos
    Dragomir, Bogdan Radu
    Chehab, Alice
    Panaite, Tinela
    Papadopoulos, Moschos A.
    Zetu, Irina
    APPLIED SCIENCES-BASEL, 2023, 13 (08):
  • [6] A clinical strategy for maxillary molar intrusion using orthodontic mini-implants and a customized palatal arch
    Cousley, Richard R. J.
    JOURNAL OF ORTHODONTICS, 2010, 37 (03) : 202 - 208
  • [7] Intrusion of maxillary molar using mini-implants: A clinical report and follow-up at 5 years
    Maio Pinzan-Vercelino, Celia Regina
    Bramante, Fausto Silva
    Gurgel, Julio de Araujo
    Carrera Eleres Vergani, Eliane Cristina
    Gregorio, Rosyane de Souza
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (01): : 1 - 4
  • [8] Comparison of tooth displacement between buccal mini-implants and palatal plate anchorage for molar distalization: a finite element study
    Yu, Il-Jun
    Kook, Yoon-Ah
    Sung, Sang-Jin
    Lee, Kee-Joon
    Chun, Youn-Sic
    Mo, Sung-Seo
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (04) : 394 - 402
  • [9] Osseointegrated implants with pendulum springs for maxillary molar distalization:: A cephalometric study
    Oencag, Goekhan
    Seckin, Oezlem
    Dincer, Banu
    Arikan, Fatih
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (01) : 16 - 26
  • [10] Maxillary molar intrusion using mini-implants in the anterior palate - "Mousetrap" versus "Mini-Mousetrap"
    Wilmes, Benedict
    Vasudavan, Sivabalan
    Drescher, Dieter