Demand-Side Contribution to Primary Frequency Control With Wind Farm Auxiliary Control

被引:56
|
作者
Molina-Garcia, Angel [1 ]
Munoz-Benavente, Irene [1 ]
Hansen, Anca D. [2 ]
Gomez-Lazaro, Emilio [3 ]
机构
[1] Univ Politecn Cartagena, Dept Elect Engn, Cartagena 30202, Spain
[2] Tech Univ Denmark, DTU Wind Energy, DK-4000 Roskilde, Denmark
[3] Univ Castilla La Mancha, Renewable Energy Inst, Albacete 02071, Spain
关键词
Frequency control; load management; wind power generation; POWER FLUCTUATIONS;
D O I
10.1109/TPWRS.2014.2300182
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Maintaining a close balance between power generation and demand is essential for sustaining the quality and reliability of a power system. Currently, due to increased renewable energy generation, frequency deviations and power fluctuations of greater concern are being introduced to the grid, particularly in regions that are weakly interconnected with their surrounding areas, such as small islands. This paper addresses the problem of frequency control in isolated power systems with relevant inclusion of wind power generation. With this aim, we have analyzed the contribution of the demand side to the primary frequency control together with an auxiliary frequency control, which is carried out by variable-speed wind turbines through an additional control loop that synthesizes virtual inertia. We have evaluated both the suitability of these two additional control actions counteracting frequency deviation and their potential reserves and compatibility. The results indicate a substantial improvement in both the dynamic performance and grid frequency stability. Simulations also indicate a decrease in the steady-state frequency error, which may relieve the secondary frequency control.
引用
收藏
页码:2391 / 2399
页数:9
相关论文
共 50 条
  • [1] Decentralized Demand-Side Contribution to Primary Frequency Control
    Molina-Garcia, Angel
    Bouffard, Francois
    Kirschen, Daniel S.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (01) : 411 - 419
  • [2] Contribution of Demand-Side to Primary Frequency Control in High Wind Energy Penetration Power Systems
    Villena-Lapaz, J. E.
    Vigueras-Rodriguez, A.
    Gomez-Lazaro, E.
    Munoz-Benavente, I.
    Molina-Garcia, A.
    Kirschen, D.
    9TH INTERNATIONAL WORKSHOP ON LARGE-SCALE INTEGRATION OF WIND POWER INTO POWER SYSTEMS AS WELL AS ON TRANSMISSION NETWORKS FOR OFFSHORE WIND POWER PLANTS, 2010, : 735 - 740
  • [3] Wind Farm Contribution to Primary Frequency Control
    Suryana, Rahmat
    Hofmann, Wilfried
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [4] Hierarchical Decentralized Control Strategy for Demand-Side Primary Frequency Response
    Lian, Jianming
    Hansen, Jacob
    Marinovici, Laurentiu D.
    Kalsi, Karanjit
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [5] A Hierarchical Framework for Demand-Side Frequency Control
    Moya, Christian
    Zhang, Wei
    Lian, Jianming
    Kalsi, Karanjit
    2014 AMERICAN CONTROL CONFERENCE (ACC), 2014, : 52 - 57
  • [6] Primary Control by ON/OFF Demand-Side Devices
    Biegel, Benjamin
    Hansen, Lars Henrik
    Andersen, Palle
    Stoustrup, Jakob
    IEEE TRANSACTIONS ON SMART GRID, 2013, 4 (04) : 2061 - 2071
  • [7] Development of a Water Heater Population Control for the Demand-side Frequency Control
    Obaid, Zeyad Assi
    Cipcigan, L. M.
    Muhssin, Mazin T.
    Sami, Saif Sabah
    2017 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE EUROPE (ISGT-EUROPE), 2017,
  • [8] Investigation of the Line Frequency for Demand-Side Primary Frequency Control Using Behind-the-Meter Home Batteries
    Zurfi, Ahmed
    Zhang, Jing
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2018, 8 (02): : 784 - 796
  • [10] The Intermittent Characteristic of Demand-side Resources and Corresponding Cooperative Frequency Control Strategy
    Ding, Zhetong
    Huang, Mingyu
    Zhang, Kaifeng
    Wang, Ying
    Li, Yaping
    2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,