A new bioabsorbable sleeve for lung staple-line reinforcement (FOREsealTM):: report of a three-center phase II clinical trial

被引:15
|
作者
Thomas, Pascal
Massard, Gilbert
Porte, Henri
Doddoli, Christophe
Ducrocq, Xavier
Conti, Massimo
机构
[1] Univ Hosp Marseille, Dept Thorac Surg, Marseille, France
[2] Univ Hosp Strasbourg, Dept Thorac Surg, Strasbourg, France
[3] Univ Hosp Lille, Dept Thorac Surg, Lille, France
关键词
lung surgery; new technology;
D O I
10.1016/j.ejcts.2006.01.067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To investigate on the feasibility, safety, and effectiveness of a new bioabsorbable material for lung staple-tine reinforcement. Methods: This prospective open trial included 66 patients (mean age of 56 +/- 17 years) who underwent various types of lung resection using staplers with knitted calcium alginate sleeves for buttressing (FOREseal (TM), Laboratoires Brothier, Nanterre, France) at three academic centers: 29 lobectomies, 22 emphysema surgeries, 15 wedge resections or lung biopsies. Intraoperative air leakage was assessed at a mean respiratory peak pressure of 30 cmH(2)O, and rated as grade 1, 2, or 3. Persistent air leakage in the postoperative course, as well as any relevant event, was assessed daily. The follow-up period was of 6 months. Results: No technical problem linked to the device occurred. Hemostasis of the cutting edges was completed in all patients. Fifty-six percent of the patients had no intraoperative air leak and 27.3% had grade 1 leaks. Mean postoperative air leaks and thoracic drainage times were 1.9 +/- 2.3 days and 6 +/- 5.3 days, respectively. In-hospital mortality was nit. There was no empyema. Mean hospital stay was 9.1 +/- 6.6 days. At follow-up, one patient underwent lung transplantation, and pathology of the explanted specimen showed the absence of device-related foreign-body inflammation. One patient complained from metalloptysis, and another one, with a metastatic invasive aspergillosis, developed an infectious recurrence that required reoperation. Conclusions: FOREseal is an ergonomic, safe, and promising new material instead of nonabsorbable materials and xenomaterials for staple-tine reinforcement. A randomized comparative study is now in progress. (c) 2006 Elsevier B.V. All. rights reserved.
引用
收藏
页码:880 / 885
页数:6
相关论文
共 50 条
  • [1] A New Bioabsorbable Sleeve for Staple-Line Reinforcement: Report of a Clinical Experience
    Yukihito Saito
    Hideyasu Omiya
    Yuzo Shomura
    Ken-ichiro Minami
    Hiroji Imamura
    Surgery Today, 2002, 32 : 297 - 299
  • [2] A new bioabsorbable sleeve for staple-line reinforcement: Report of a clinical experience
    Saito, Y
    Omiya, H
    Shomura, Y
    Minami, KI
    Imamura, H
    SURGERY TODAY, 2002, 32 (04) : 297 - 299
  • [3] Laparoscopic sleeve gastrectomy for morbid obesity using Seamguard® bioabsorbable staple-line reinforcement
    Catheline, JM
    Charara, M
    Perez, M
    Benichou, J
    Cohen, R
    Reach, G
    OBESITY SURGERY, 2006, 16 (04) : 401 - 401
  • [4] A PROSPECTIVE COMPARISON OF THREE STAPLE-LINE REINFORCEMENT OF LAPAROSCOPIC SLEEVE GASTRECTOMY
    Contreras, J. E.
    Hamilton, J.
    Court, I
    Brante, P.
    Bravo, J.
    Marin, P.
    Diaz, J.
    OBESITY SURGERY, 2016, 26 : S163 - S163
  • [5] Staple-line reinforcement during laparoscopic sleeve gastrectomy using three different techniques: a randomized trial
    Gentileschi, Paolo
    Camperchioli, Ida
    D'Ugo, Stefano
    Benavoli, Domenico
    Gaspari, Achille L.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (09): : 2623 - 2629
  • [6] Staple-line reinforcement during laparoscopic sleeve gastrectomy using three different techniques: a randomized trial
    Paolo Gentileschi
    Ida Camperchioli
    Stefano D’Ugo
    Domenico Benavoli
    Achille L. Gaspari
    Surgical Endoscopy, 2012, 26 : 2623 - 2629
  • [7] TUMOR RELAPSE AFTER SURGERY USING A SLEEVE FOR LUNG STAPLE-LINE REINFORCEMENT: NOT ALWAYS!
    Garcia, Marie-Eve
    Tomasini, Pascale
    Thomas, Pascal
    Greillier, Laurent
    Barlesi, Fabrice
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S896 - S896
  • [8] Clinical Results Using Bioabsorbable Staple-Line Reinforcement for Circular Stapler in Colorectal Surgery: A Multicenter Study
    Portillo, Guillermo
    Franklin, Morris E., Jr.
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2010, 20 (04): : 323 - 327
  • [9] Buttressing the staple line in lung volume reduction surgery: A randomized three-center study
    Stammberger, U
    Klepetko, W
    Stamatis, G
    Hamacher, J
    Schmid, RA
    Wisser, W
    Hillerjan, L
    Weder, W
    ANNALS OF THORACIC SURGERY, 2000, 70 (06): : 1820 - 1825
  • [10] Safety and efficacy of new staple-line reinforcement in lung resection: a prospective study of 48 patients
    Mitsui, Suguru
    Tanaka, Yugo
    Nishikubo, Megumi
    Doi, Takefumi
    Tane, Shinya
    Hokka, Daisuke
    Mitomo, Yuji
    Maniwa, Yoshimasa
    SURGERY TODAY, 2024, 54 (07) : 779 - 786