Systematic Modeling of Municipal Wastewater Activated Sludge Process and Treatment Plant Capacity Analysis Using GPS-X

被引:29
|
作者
Mu'azu, Nuhu Dalhat [1 ]
Alagha, Omar [1 ]
Anil, Ismail [1 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Dept Environm Engn, Coll Engn, POB 1982, Dammam 31451, Saudi Arabia
关键词
activated sludge model 1 (ASM1); GPS-X Mantis model l model; model calibration and validation; municipal wastewater management; stoichiometric and kinetic parameters; treatment performance evaluation; BIOLOGICAL NITROGEN REMOVAL; NUTRIENT REMOVAL; NITRIFICATION; DENITRIFICATION; SIMULATION; PARAMETERS; OPTIMIZATION; VARIABILITY; CALIBRATION; RATIOS;
D O I
10.3390/su12198182
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Mathematical modeling has become an indispensable tool for sustainable wastewater management, especially for the simulation of complex biochemical processes involved in the activated sludge process (ASP), which requires a substantial amount of data related to wastewater and sludge characteristics as well as process kinetics and stoichiometry. In this study, a systematic approach for calibration of the activated sludge model one (ASM1) model for a real municipal wastewater ASP was undertaken in GPS-X. The developed model was successfully validated while meeting the assumption of the model's constant stoichiometry and kinetic coefficients for any plant influent compositions. The influences of vital ASP parameters on the treatment plant performance and capacity analysis for meeting local discharge limits were also investigated. Lower influent chemical oxygen demand in mgO(2)/L (COD) could inhibit effective nitrification and denitrification, while beyond 250 mgO(2)/L, there is a tendency for effluent quality to breach the regulatory limit. The plant performance can be satisfactory for handling even higher influent volumes up to 60,000 m(3)/d and organic loading when Total Suspended Solids/Volatile Suspended Solids (VSS/TSS) and particulate COD (X-COD)/VSS are maintained above 0.7 and 1, respectively. The wasted activated sludge (WAS) has more impact on the effluent quality compared to recycle activated sludge (RAS) with significant performance improvement when the WAS was increased from 3000 to 9000 m(3)/d. Hydraulic retention time (HRT) > 6 h and solids retention time (SRT) < 7 days resulted in better plant performance with the SRT having greater impact compared with HRT. The plant performance could be sustained for a quite appreciable range of COD/5-day Biochemical Oxygen Demand (BOD5 in mgO(2)/L) ratio, Mixed Liquor Suspended Solid (MLSS) of up to 6000 mg/L, and when BOD5/total nitrogen (TN) and COD/TN are comparatively at higher values. This work demonstrated a systematic approach for estimation of the wastewater treatment plant (WWTP) ASP parameters and the high modeling capabilities of ASM1 in GPS-X when respirometry tests data are lacking.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Quality and cost analysis of a wastewater treatment plant using GPS-X and CapdetWorks simulation programs
    Abbasi, Nazanin
    Ahmadi, Maryam
    Naseri, Maryam
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2021, 284
  • [2] Modelling of Activated Sludge Wastewater Treatment Process in Municipal Plant in Velika Gorica
    Curlin, M.
    Bevetek, A.
    Lezajic, Z.
    Mestrovic, B. Deveric
    Kurtanjek, Z.
    KEMIJA U INDUSTRIJI-JOURNAL OF CHEMISTS AND CHEMICAL ENGINEERS, 2008, 57 (02): : 59 - 67
  • [3] MODELING AND SIMULATION OF AN URBAN WASTEWATER TREATMENT PLANT WITH AN ANOXIC-AEROBIC-MBR SYSTEM USING GPS-X SOFTWARE
    Medellin-Castillo, Nahum Andres
    Gonzalez-Martinez, Alvaro
    Barrios-Pina, Hector
    Espinosa-Rodriguez, Miguel Angel
    Gonzalez-Fernandez, Lazaro Adrian
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2023, 22 (11): : 1925 - 1937
  • [4] Evaluation of nitrification and denitrificationin an activated sludge process through mass CONTENIDO balance using GPS-X software
    Medellin-Castillo, N. A.
    Arvizu-Vazquez, S.
    Gallegos-Garcia, M.
    Hidalgo-Millan, A.
    Espinosa-Rodriguez, M. A.
    REVISTA MEXICANA DE INGENIERIA QUIMICA, 2024, 23 (03):
  • [5] A PRACTICAL APPROACH FOR TREATMENT OF MUNICIPAL WASTEWATER BY ACTIVATED SLUDGE PROCESS
    Nas, S. S.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2013, 14 (03): : 1030 - 1040
  • [6] Circulation of microplastics in a municipal wastewater treatment plant with multiphase activated sludge
    Ormaniec, Paulina
    Mikosz, Jerzy
    DESALINATION AND WATER TREATMENT, 2024, 317
  • [7] Improving the operational performance of a wastewater treatment plant by using GPS-X simulations: a case study in northern Taiwan
    Chen, Kuen-Lin
    Hou, Ching-Wen
    Liu, Chen-Wuing
    Wang, Han-Yi
    SUSTAINABLE ENVIRONMENT RESEARCH, 2025, 35 (01)
  • [8] Impact of Combined Electrolysis and Activated Sludge Process on Municipal Wastewater Treatment
    Hutnan, Miroslav
    Jankovicova, Barbora
    Zakhar, Ronald
    Soltysova, Nikola
    PROCESSES, 2024, 12 (05)
  • [9] Integration of membrane filtration into the activated sludge process in municipal wastewater treatment
    Engelhardt, N
    Firk, W
    Warnken, W
    WATER SCIENCE AND TECHNOLOGY, 1998, 38 (4-5) : 429 - 436
  • [10] Immersed membranes activated sludge process applied to the treatment of municipal wastewater
    Côté, P
    Buisson, H
    Praderie, M
    WATER SCIENCE AND TECHNOLOGY, 1998, 38 (4-5) : 437 - 442