Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass spectrometry

被引:50
|
作者
Grant, RP [1 ]
Cameron, C [1 ]
Mackenzie-McMurter, S [1 ]
机构
[1] Eli Lily Canada Inc, Lilly Lab Bioanalyt Res, Toronto, ON M1N 2E8, Canada
关键词
D O I
10.1002/rcm.784
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The development of turbulent flow chromatography (TFC) has enabled considerable growth in the utility of on-line direct-injection technologies. TFC has now become established in a large number of varied analytical environments, particularly drug discovery/pharmacokinetics, metabolite profiling, combinatorial library purification, pre-clinical and clinical GLP applications. The utility of turbulent flow technology for in-house pre-clinical and clinical quantitative applications has necessitated extensive valve-cleaning procedures, and consequently lengthy cycle-times, to effectively remove the system carry-over. In-house requirements for assay validation require carry-over less than 20% of the lowest level of quantification (LLOQ), corresponding to 0.02% carry-over for a linear calibration range incorporating 3 orders. A generic turbulent flow chromatography protocol has been developed for drug discovery that incorporates polymeric turbulent flow extraction (cyclone) with C18-based reverse-phase chromatography. Further, multiple wash steps are incorporated within the methodology to meet in-house requirements for carry-over. Selection of novel switching-valve materials based on polyarylethyl ketone (PAEK) and Hastelloy/Valcon E autosampler injection hardware has enabled us to significantly impact the cycle-time required to reduce carry-over. Consequently, optimal usage of switching valves has enabled parallel operation for a generic on-line direct-injection methodology to successfully reduce the total cycle-time. Overall reductions from 4 min per sample to 90 s per sample are shown with comparable data quality using a proprietary target molecule from 0.1-100 ng/mL. This paper describes the hardware configuration and methodologies utilized to perform generic serial and parallel on-line direct-injection using a Turboflow HTLC 2300 system. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:1785 / 1792
页数:8
相关论文
共 50 条
  • [1] Increased productivity in quantitative bioanalysis using a monolithic column coupled with high-flow direct-injection liquid chromatography/tandem mass spectrometry
    Huang, Mike-Qingtao
    Mao, Yan
    Jemal, Mohammed
    Arnold, Mark
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (11) : 1709 - 1714
  • [2] Quantitative determination of a novel dual PPAR α/γ agonist using on-line turbulent flow extraction with liquid chromatography-tandem mass spectrometry
    Xu, XH
    Yan, KX
    Song, HC
    Lo, MW
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 814 (01): : 29 - 36
  • [3] Analysis of organophosphorus flame retardants in environmental and biotic matrices using on-line turbulent flow chromatography-liquid chromatography-tandem mass spectrometry
    Giulivo, Monica
    Capri, Ettore
    Eljarrat, Ethel
    Barcelo, Damia
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1474 : 71 - 78
  • [4] Analysis of endocrine disrupters and related compounds in sediments and sewage sludge using on-line turbulent flow chromatography-liquid chromatography-tandem mass spectrometry
    Gorga, Marina
    Insa, Sara
    Petrovic, Mira
    Barcelo, Damia
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1352 : 29 - 37
  • [5] High-throughput determination of cortisol, cortisone, and melatonin in oral fluid by on-line turbulent flow liquid chromatography interfaced with liquid chromatography/tandem mass spectrometry
    Fustinoni, Silvia
    Polledri, Elisa
    Mercadante, Rosa
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (13) : 1450 - 1460
  • [6] Ternary-column system for high-throughput direct-injection bioanalysis by liquid chromatography/tandem mass spectrometry
    Xia, YQ
    Whigan, DB
    Powell, ML
    Jemal, M
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (02) : 105 - 111
  • [7] High-throughput biological sample analysis using on-line turbulent flow extraction combined with monolithic column liquid chromatography/tandem mass spectrometry
    Zhou, SL
    Zhou, HY
    Larson, M
    Miller, DL
    Mao, DM
    Jiang, XY
    Weng, ND
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (15) : 2144 - 2150
  • [8] Quantitative liquid chromatography-mass spectrometry determination of catechins in human plasma by automated on-line extraction using turbulent flow chromatography
    Takino, M
    Daishima, S
    Yamaguchi, K
    Nakahara, T
    ANALYST, 2003, 128 (01) : 46 - 50
  • [9] Direct analysis of the mushroom poisons α- and β-amanitin in human urine using a novel on-line turbulent flow chromatography mode coupled to liquid chromatography-high resolution-mass spectrometry/mass spectrometry
    Helfer, Andreas G.
    Meyer, Markus R.
    Michely, Julian A.
    Maurer, Hans H.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1325 : 92 - 98
  • [10] Serial sampling in the mouse in support of pharmacokinetic studies with turbulent flow chromatography and tandem mass spectrometry
    J. M. Long
    C. A. James
    B. J. Clark
    M. G. Castelli
    S. Rolando
    Chromatographia, 2002, 55 : S31 - S34