Profile measurement of silicon wafer by laser autocollimation

被引:0
|
作者
Gao, W [1 ]
Yamada, T [1 ]
Kiyono, S [1 ]
Huang, PS [1 ]
机构
[1] Tohoku Univ, Dept Mechatron & Precis Engn, Sendai, Miyagi 9808579, Japan
关键词
measurement; flatness; angle probe; laser autocolliation;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes an angle-probe based scanning system for flatness measurement of silicon wafers. An angle probe is used to scan the wafer surface to get local slopes of the surface without being influenced by the straightness error of the scanning motion. The profile height of the wafer surface can then be obtained from integrating the angle probe output with respect to distance along the scanning direction. A compact and sensitive angle probe utilizing the principle of laser autocollimation was designed and made specifically for the scanning system. The angle probe was confirmed to have a resolution higher than 0.01 arc-seconds. An experimental scanning system was also constructed to measure the surface profile of a 200 mm diameter silicon wafer using the angle probe. Measurements of the cross-sectional profile along a line on the wafer surface were conducted.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 50 条
  • [1] Laser scattering measurement of microdefects on silicon oxide wafer
    Ha, T
    Miyoshi, T
    Takaya, Y
    Takahashi, S
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS VI, 2005, 295-296 : 3 - 8
  • [2] HIGH-ACCURACY PROFILE MEASUREMENT OF QUASI-CONICAL MIRROR SURFACES BY LASER AUTOCOLLIMATION
    ENNOS, AE
    VIRDEE, MS
    PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1982, 4 (01): : 5 - 8
  • [3] Measurement of thickness profile and refractive index variation of a silicon wafer using the optical comb of a femtosecond pulse laser
    Park, Jungjae
    Jin, Jonghan
    Kim, Jae Wan
    Kim, Jong-Ahn
    OPTICS COMMUNICATIONS, 2013, 305 : 170 - 174
  • [4] Differential laser autocollimation probe for on-machine-measurement
    Kivono, S.
    Asakawa, Y.
    Kamada, O.
    Kume, T.
    Proceedings of the International Precision Engineering Seminar, 1991,
  • [5] A DIFFERENTIAL LASER AUTOCOLLIMATION PROBE FOR ON-MACHINE MEASUREMENT
    KIYONO, S
    ASAKAWA, Y
    INAMOTO, M
    KAMADA, O
    PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1993, 15 (02): : 68 - 76
  • [6] PRECISION-MEASUREMENT OF SURFACE FORM BY LASER AUTOCOLLIMATION
    ENNOS, AE
    VIRDEE, MS
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 398 : 252 - 257
  • [7] Laser dicing of silicon wafer
    Tang, Y.
    Fuh, J. Y. H.
    Loh, H. T.
    Wong, Y. S.
    Lim, Y. K.
    SURFACE REVIEW AND LETTERS, 2008, 15 (1-2) : 153 - 159
  • [8] Laser autocollimation measurement of small angle based on cross correlation
    Huang, Yin-Guo
    Lin, Yu-Chi
    Wang, Wei
    Zhao, Mei-Rong
    Nami Jishu yu Jingmi Gongcheng/Nanotechnology and Precision Engineering, 2010, 8 (02): : 120 - 125
  • [9] Automatic defects measurement on silicon wafer surface by laser scattered defect pattern
    Takahashi, Satoru
    Miyoshi, Takashi
    Takaya, Yasuhiro
    American Society of Mechanical Engineers, Manufacturing Engineering Division, MED, 2000, 11 : 209 - 214
  • [10] Surface profile measurement of highly reflective silicon wafer using wavelength tuning interferometer
    Kim, Yangjin
    Sugita, Naohiko
    Mitsuishi, Mamoru
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XXX, 2016, 9778