Do device characteristics impact outcome in carotid artery stenting?

被引:96
|
作者
Hart, Joseph P.
Peeters, Patrick
Verbist, Jurgen
Deloose, Koen
Bosiers, Marc
机构
[1] AZ St Blasius, Dept Vasc Surg, B-9200 Dendermonde, Belgium
[2] Univ Rochester, Imelda Hosp, Med Ctr, Dept Cardiovasc & Thorac Surg, Rochester, NY 14627 USA
关键词
D O I
10.1016/j.jvs.2006.06.029
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: The study was conducted to identify patient and procedural parameters that negatively impact the 30-day rates for stroke, death and transient ischemic attack (TIA) after carotid artery stenting (CAS) and that might be modified or further studied in future efforts to improve CAS. Methods: This was a retrospective investigation of a dual-center CAS database of 701 consecutive CAS patients (414 men; mean age, 72.4 +/- 8.4). A subset of patient-related, lesion-related, or procedure-related variables (age >= 80, left sided lesion, symptomatic, nicotine abuse, hypertension, diabetes mellitus, other peripheral vascular disease, hypercholesterolemia, embolic protection devices usage, predilation, ulcerated lesion, echolucent plaque, restenosis after surgery) were analyzed for association with occurrence of stroke, death, or TIA <= 30 days after CAS. The odds ratio (OR) and 95% confidence interval (CI) and P value were calculated for each variable to predict adverse outcome. Results: The overall combined rate of stroke, death, and TIA within this database was 3.7% at 30 days. In the total population of 701 patients, only the OR of 2.7 for hypercholesterolemia (95% CI, 1.0 to 7.3; P = .041) was found to be significant. Subgroup analysis of the 304 symptomatic patients (43%) showed that open-cell stent designs and concentric EPD designs yielded an OR of 4.1 (95% CI, 1.4 to 12, P = .0136) and 3.3 (95% CI, 1.016 to 10, P = .0525), respectively, for 30-day stroke/death/TIA within this database. Analysis of open-cell stent designs and concentric EPD designs in patients with echolucent lesions yielded an OR of 3.1 (95% CI, 1.2 to 8.2, P = .0343) and 3.7 (95% CI, 1.3 to 10, P = .0174), respectively, for 30-day stroke/death/TIA. Conclusions: We conclude that increased analysis of device design variables may be necessary. Particularly in symptomatic patients or with echolucent lesions, closed-cell design and eccentric filters seem superior. Prospective investigation comparing open-cell vs closed-cell stents and eccentric vs concentric filter devices may be warranted.
引用
收藏
页码:725 / 730
页数:6
相关论文
共 50 条
  • [1] Do device characteristics impact outcome in carotid artery stenting? - Discussion
    Schneiderman, Jacob
    Hart, Joseph P.
    Hobson, Robert
    Schermerhorn, Marc
    Illig, Karl
    Johnston, K. Wayne
    JOURNAL OF VASCULAR SURGERY, 2006, 44 (04) : 730 - 730
  • [2] Do device characteristics impact outcome in carotid artery stenting? - Invited commentary
    Becquemin, Jean-Pierre
    JOURNAL OF VASCULAR SURGERY, 2006, 44 (04) : 731 - 731
  • [3] Do device characteristics impact outcome in carotid artery stenting? (vol 44, pg 725, 2006)
    Hart, J. P.
    Peeters, P.
    Verbist, J.
    Deloose, K.
    Bosiers, M.
    JOURNAL OF VASCULAR SURGERY, 2007, 45 (01) : 226 - 226
  • [4] Prospective Registry of Carotid Artery Stenting in Japan-Investigation on Device and Antiplatelet for Carotid Artery Stenting
    Sakai, Nobuyuki
    Yamagami, Hiroshi
    Matsubara, Yoshihiro
    Ezura, Masayuki
    Hyodo, Akio
    Matsumaru, Yuji
    Miyachi, Shigeru
    Okada, Yasushi
    Terada, Tomoaki
    Yokoi, Hiroyoshi
    Nakamura, Mitusugu
    Matsumoto, Yasushi
    Sakai, Chiaki
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2014, 23 (06): : 1374 - 1384
  • [5] Factors Affecting Outcome of Carotid Artery Stenting
    Agarwal, Shikhar
    AMERICAN JOURNAL OF CARDIOLOGY, 2014, 114 (09): : 1464 - 1464
  • [6] Carotid artery velocity characteristics after carotid artery angioplasty and stenting
    Chahwan, Santiago
    Miller, M. Todd
    Pigott, John P.
    Whalen, Ralph C.
    Jones, Linda
    Comerota, Anthony J.
    JOURNAL OF VASCULAR SURGERY, 2007, 45 (03) : 523 - 526
  • [7] Outcome of Carotid Artery Stenting in Patient with Combined Carotid and Coronary Artery Disease
    Pasciolly, Mohammad Reza Juniery
    Mathur, Atul
    Seth, Ashok
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S29 - S30
  • [8] Impact On Outcome Of Different Types Of Carotid Stents: Results From The European Registry Of Carotid Artery Stenting
    Stabile, Eugenio
    Garg, Pallav
    Cremonesi, Alberto
    Bosiers, Marc
    Reimers, Bernhard
    Setacci, Carlo
    Cao, Piergiorgio
    Schmidt, Andrej
    Sievert, Horst
    Peeters, Patrick
    Nikas, Dimitrios
    Werner, Martin
    de Donato, Gianmarco
    Parlani, Giambattista
    Castriota, Fausto
    Hornung, Marius
    Mauri, Laura
    Giugliano, Giuseppe
    Esposito, Giovanni
    Rubino, Paolo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B155 - B155
  • [9] Impact on outcome of different types of carotid stent: results from the European Registry of Carotid Artery Stenting
    Stabile, Eugenio
    Giugliano, Giuseppe
    Cremonesi, Alberto
    Bosiers, Marc
    Reimers, Bernhard
    Setaeei, Carlo
    Cao, Piergiorgio
    Schmidt, Andrej
    Sievert, Horst
    Peeters, Patrick
    Nikas, Dimitrios
    Sannino, Anna
    de Donato, Gianmarco
    Parlani, Giambattista
    Castriota, Fausto
    Hornung, Marius
    Rubino, Paolo
    Esposito, Giovanni
    Tesorio, Tullio
    EUROINTERVENTION, 2016, 12 (02) : E265 - E270
  • [10] Flow impairment during protected carotid artery stenting: Impact of filter device design
    Roffi, Marco
    Greutmann, Matthias
    Schwarz, Urs
    Luscher, Thomas F.
    Eberli, Franz R.
    Amann-Vesti, Beatrice
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (01) : 103 - 109