IR spectral characterization of customer blackbody sources: first calibration results

被引:1
|
作者
Mekhontsev, S. [1 ]
Noorma, M. [1 ]
Prokhorov, A. [1 ]
Hanssen, L. [1 ]
机构
[1] Natl Inst Stand & Technol, Opt Technol Div, Gaithersburg, MD 20899 USA
来源
THERMOSENSE XXVIII | 2006年 / 6205卷
关键词
infrared; spectral radiance; temperature; fixed-point blackbody; spectral emissivity;
D O I
10.1117/12.667523
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We summarize recent progress in our infrared (IR) spectral radiance metrology effort. In support of customer blackbody characterization, a realization of the spectral radiance scale has been undertaken in the temperature range of 232 degrees C to 962 degrees C and spectral range of 2.5 mu m to 20 mu m. We discuss the scale realization process that includes the use of Sn, Zn, Al and Ag fixed-point blackbodies (BB), as well as the transfer of the spectral radiance scale to transfer standard BBs based on water, Cs and Na heat pipes. Further we discuss the procedures for customer source calibration with several examples of the spectral radiance and ernissivity measurements of secondary standard BB sources. For one of the BBs, a substantial deviation of emissivity values from the manufacturer specifications was found. Further plans include expansion of the adopted methodology for temperatures down to 15 degrees C and building a dedicated facility for spectral characterization of IR radiation sources.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Blackbody Radiation Sources for the IR Spectral Range
    Ogarev, S. A.
    Morozova, S. P.
    Katysheva, A. A.
    Lisiansky, B. E.
    Samoylov, M. L.
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 654 - 659
  • [2] Comparison of Blackbody Sources for Low-Temperature IR Calibration
    S. Ljungblad
    M. Holmsten
    L. E. Josefson
    P. Klason
    International Journal of Thermophysics, 2015, 36 : 3310 - 3319
  • [3] Comparison of Blackbody Sources for Low-Temperature IR Calibration
    Ljungblad, S.
    Holmsten, M.
    Josefson, L. E.
    Klason, P.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (12) : 3310 - 3319
  • [4] Blackbody calibration sources
    Merchant, J
    MEASUREMENTS & CONTROL, 1996, (175): : 114 - 117
  • [5] Spectroradiometric calibration of blackbody sources
    Madding, RP
    THERMOSENSE XXIII, 2001, 4360 : 363 - 371
  • [6] Theory and construction of blackbody calibration sources
    Irani, K
    THERMOSENSE XXIII, 2001, 4360 : 347 - 362
  • [7] BLACKBODY CALIBRATION SOURCES FUNCTION AS STANDARDS
    MERCHANT, J
    LASER FOCUS WORLD, 1995, 31 (04): : 105 - &
  • [8] How to choose an IR blackbody calibration source
    Baghai, S
    R&D MAGAZINE, 2004, 46 (07): : 31 - 31
  • [9] In-flight blackbody calibration sources for the GLORIA interferometer
    Olschewski, F.
    Rolf, C.
    Steffens, P.
    Kleinert, A.
    Piesch, C.
    Ebersoldt, A.
    Monte, C.
    Gutschwager, B.
    Hollandt, J.
    Preusse, P.
    Friedl-Vallon, F.
    Koppmann, R.
    INFRARED REMOTE SENSING AND INSTRUMENTATION XX, 2012, 8511
  • [10] Design, manufacture, and calibration of infrared radiometric blackbody sources
    Byrd, DA
    Michaud, FD
    Bender, SC
    Luettgen, AL
    Holland, RF
    Atkins, WH
    OBrian, TR
    Lorentz, SR
    INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING VII, 1996, 2743 : 216 - 226