The Feasibility of High-Resolution Peripheral Quantitative Computed Tomography (HR-pQCT) in Patients with Suspected Scaphoid Fractures

被引:11
|
作者
Bevers, M. S. A. M. [1 ]
Daniels, A. M. [2 ,3 ]
Wyers, C. E. [3 ,4 ,5 ]
van Rietbergen, B. [6 ]
Geusens, P. P. M. M. [5 ]
Kaarsemaker, S. [8 ]
Janzing, H. M. J. [2 ]
Hannemann, P. F. W. [9 ]
Poeze, M. [3 ,9 ]
van den Bergh, J. P. W. [3 ,4 ,5 ,7 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Orthopaed Biomech, Eindhoven, Netherlands
[2] VieCuri Med Ctr, Dept Surg, Venlo, Netherlands
[3] Maastricht Univ, NUTRIM Sch Nutr & Translat Res Metab, Maastricht, Netherlands
[4] VieCuri Med Ctr, Dept Internal Med, Subdiv Endocrinol, Venlo, Netherlands
[5] Maastricht Univ, Med Ctr, Dept Internal Med, Maastricht, Netherlands
[6] Maastricht Univ, Med Ctr, Res Sch CAPHRI, Dept Orthopaed Surg, Maastricht, Netherlands
[7] Hasselt Univ, Fac Med, Hasselt, Belgium
[8] VieCuri Med Ctr, Dept Orthopaed Surg, Venlo, Netherlands
[9] Maastricht Univ, Med Ctr, Dept Surg & Trauma Surg, Maastricht, Netherlands
关键词
scaphoid fracture; high-resolution peripheral quantitative computed tomography; in vivo imag-ing; scan quality; automatic contouring algorithm; BONE MICROARCHITECTURE; DISTAL RADIUS; PARAMETERS; REPRODUCIBILITY; MICROSTRUCTURE; PREVALENCE; MANAGEMENT; DIAGNOSIS; QUALITY; MOTION;
D O I
10.1016/j.jocd.2019.08.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Diagnosing scaphoid fractures remains challenging. High-resolution peripheral quantitative computed tomography (HR-pQCT) might be a potential imaging technique, but no data are available on its feasibility to scan the scaphoid bone in vivo. Methodology: Patients ( 18 years) with a clinically suspected scaphoid fracture received an HR-pQCT scan of the scaphoid bone (three 10.2-mm stacks, 61 -mm voxel size) with their wrist immobilized with a cast. Scan quality assessment and bone contouring were performed using methods originally developed for HR-pQCT scans of radius and tibia. The contouring algorithm was applied on coarse hand-drawn pre-contours of the scaphoid bone, and the resulting contours (AUTO) were manually corrected (sAUTO) when visually deviating from bone margins. Standard morphologic analyses were performed on the AUTOand sAUTO-contoured bones. Results: Ninety-one patients were scanned. Two out of the first five scans were repeated due to poor scan quality (40%) based on standard quality assessment during scanning, which decreased to three out of the next 86 scans (3.5%) when using an additional thumb cast. Nevertheless, after excluding one scan with an incompletely scanned scaphoid bone, post hoc grading revealed a poor quality in 14.9% of the stacks and 32.9% of the scans in the remaining 85 patients. After excluding two scans with contouring problems due to scan quality, bone indices obtained by AUTOand sAUTO-contouring were compared in 83 scans. All AUTO-contours were manually corrected, resulting in significant but small differences in densitometric and trabecular indices (<1.0%). Conclusions: In vivo HR-pQCT scanning of the scaphoid bone is feasible in patients with a clinically suspected scaphoid fracture when using a cast with thumb part. The proportion of poor-quality stacks is similar to radius scans, and AUTO -contouring appears appropriate in goodand poor-quality scans . Thus, HR-pQCT may be promising for diagnosis of and microarchitectural evaluations in suspected scaphoid fractures.
引用
收藏
页码:432 / 442
页数:11
相关论文
共 50 条
  • [1] The feasibility of high-resolution peripheral quantitative computed tomography (HR-pQCT) in patients with a suspected scaphoid fracture
    Bevers, Melissa S. A. M.
    Daniels, Anne M.
    Wyers, Caroline E.
    van Rietbergen, Bert
    Geusens, Piet P. M. M.
    Kaarsemaker, Sjoerd
    Janzing, Heinrich M. J.
    Hannemann, Pascal F. W.
    Poeze, Martijn
    van den Bergh, Joop P. W.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2019, 34 : 293 - 294
  • [2] Evaluation of bone microarchitecture by high-resolution peripheral quantitative computed tomography (HR-pQCT) in hemodialysis patients
    Negri, A. L.
    Del Valle, E. E.
    Zanchetta, M. B.
    Nobaru, M.
    Silveira, F.
    Puddu, M.
    Barone, R.
    Bogado, C. E.
    Zanchetta, J. R.
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 (10) : 2543 - 2550
  • [3] Evaluation of bone microarchitecture by high-resolution peripheral quantitative computed tomography (HR-pQCT) in hemodialysis patients
    A. L. Negri
    E. E. Del Valle
    M. B. Zanchetta
    M. Nobaru
    F. Silveira
    M. Puddu
    R. Barone
    C. E. Bogado
    J. R. Zanchetta
    Osteoporosis International, 2012, 23 : 2543 - 2550
  • [4] High-Resolution Peripheral Quantitative Computed Tomography (HR-pQCT) as a new Method for Human Osteoarcheology
    Kann, Peter Herbert
    Pommerening, Tanja
    Broemer, Rainer
    John, Christopher
    Hadji, Peyman
    JOURNAL OF BONE AND MINERAL RESEARCH, 2023, 38 : 268 - 268
  • [5] High resolution peripheral quantitative computed tomography (HR-pQCT) - clinical relevance of the results
    Haschka, J.
    Patsch, J. M.
    Kocijan, R.
    Resch, H.
    OSTEOLOGIE, 2013, 22 (01) : 13 - 17
  • [6] BONE MICROARCHITECTURE ASSESMENT BY HIGH-RESOLUTION PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY (HR-PQCT) IN HEALTHY WOMEN
    Zanchetta, Maria
    Monteverde, Carina
    Silveira, Fernando
    Ripero, Virginia
    Bogado, Cesar
    Zanchetta, Jose
    OSTEOPOROSIS INTERNATIONAL, 2011, 22 : 97 - 98
  • [7] High-Resolution Peripheral Quantitative Computed Tomography (HR-pQCT) Identification of Bony Damage in Rheumatoid Arthritis
    Barnabe, Cheryl
    Szabo, Eva
    Barr, Susan
    Boyd, Steven
    Martin, Liam
    JOURNAL OF RHEUMATOLOGY, 2010, 37 (06) : 1350 - 1350
  • [8] BONE MICROARCHITECTURE ASSESMENT BY HIGH-RESOLUTION PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY (HR-PQCT) IN HEALTHY MEN
    Belen Zanchetta, Maria
    Cecilia Jorquera, Ana
    Silveira, Fernando
    Sesta, Mariela
    Zanchetta, Jose
    Bogado, Cesar
    OSTEOPOROSIS INTERNATIONAL, 2011, 22 : 222 - 222
  • [9] EVALUATION OF BONE MICROACHITECTURE BY HIGH RESOLUTION PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY (HR-PQCT) IN HEMODIALYSIS PATIENTS
    Negri, A. L.
    Del Valle, E. E.
    Zanchetta, M. B.
    Bogado, C.
    Zanchetta, J. R.
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 : S474 - S474
  • [10] Establishment of normal female reference for high-resolution peripheral quantitative computed tomography (HR-pQCT) in the Chinese population
    Fong, Tsz Ning
    Wing-yin, Vivian
    Fiona, Hung
    Yu, Wai-ping
    Hung, Leung-kim
    Qin, Ling
    BONE, 2010, 47 : S412 - S413