Determination of 10 Kinds of Monohydroxylated Polycyclic Aromatic Hydrocarbons in Human Urine by Supported Liquid Extraction Followed by Liquid Chromatography-Tandem Mass Spectrometry

被引:13
|
作者
Shang Ting [1 ,2 ]
Zhao Ling-Juan [1 ]
Li Pei [1 ,2 ]
Zeng Xiang-Ying [1 ]
Yu Zhi-Qiang [1 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Geochem, State Key Lab Organ Geochem, Guangdong Key Lab Environm & Resources, Guangzhou 510640, Guangdong, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Monohydroxylated polycyclic aromatic hydrocarbons; Urine; Supported liquid extraction; Liquid chromatography-tandem mass spectrometry; LC-MS/MS METHOD; PAH METABOLITES; WHOLE-BLOOD; ORAL FLUID; QUANTIFICATION; INHIBITOR; EXPOSURE;
D O I
10.1016/S1872-2040(19)61165-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The monitoring of urinary monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) can be used for the risk assessment of human exposure to polycyclic aromatic hydrocarbons (PAHs). In this work, we developed and optimized a new pretreatment method based on solid-phase supported liquid-liquid extraction (SLE). After pretreatment, the analytes were then determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Urine samples were extracted with a mixed solution of dichloromethane and n-hexane (3:7, V/V) by a SLE clean-up using a diatomaceous earth mini-cartridge. The results indicated that the developed pretreated procedure had good recoveries and also significantly reduced the interference of biological matrix. At three concentration levels (10, 50 and 100 mu g/L), the recoveries of ten OH-PAHs ranged from 88.5% to 120.9%, and the repeatability ranged from 1. 6% to 8. 1%. The limits of detection ranged from 0.06 mu g/L to 0.3 mu g/L and the limits of quantitation were between 0.2 mu g/L and 1.0 mu g/L. This method was finally successfully applied to the determination of OH-PAHs in urines collected from primary school students in Guangdong. The results showed that 2-OHN was the dominant compound, with the highest concentration of 4.83 mu g/L.
引用
收藏
页码:876 / 882
页数:7
相关论文
共 29 条
  • [1] Scope and limitations of solid-supported liquid-liquid extraction for the high-throughput purification of compound libraries
    Breitenbucher, JG
    Arienti, KL
    McClure, KJ
    [J]. JOURNAL OF COMBINATORIAL CHEMISTRY, 2001, 3 (06): : 528 - 533
  • [2] Quantification of 13 priority polycyclic aromatic hydrocarbons in human urine by headspace solid-phase microextraction gas chromatography-isotope dilution mass spectrometry
    Campo, Laura
    Mercadante, Rosa
    Rossella, Federica
    Fustinoni, Silvia
    [J]. ANALYTICA CHIMICA ACTA, 2009, 631 (02) : 196 - 205
  • [3] Development of a gas chromatography/mass spectrometry method to quantify several urinary monohydroxy metabolites of polycyclic aromatic hydrocarbons in occupationally exposed subjects
    Campo, Laura
    Rossella, Federica
    Fustinoni, Silvia
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02): : 531 - 540
  • [4] A supported liquid extraction-LC-MS/MS method for determination of GDC-0980 (Apitolisib), a dual small-molecule inhibitor of class 1A phosphoinositide 3-kinase and mammalian target of rapamycin, in human plasma
    Ding, X.
    Li, F.
    McKnight, J.
    Schmidt, C.
    Strooisma, K.
    Shimizu, H.
    Faber, K.
    Ware, J. A.
    Dean, B.
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 100 : 150 - 156
  • [5] A supported liquid extraction LC-MS/MS method for determination of concentrations of GDC-0425, a small molecule Checkpoint kinase 1 inhibitor, in human plasma
    Ding, Xiao
    Chen, Yuan
    Sahasranaman, Srikumar
    Shi, Yifan
    McKnight, Janine
    Dean, Brian
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (12) : 1984 - 1991
  • [6] Determination of ten monohydroxylated polycyclic aromatic hydrocarbons by liquid-liquid extraction and liquid chromatography/tandem mass spectrometry
    Fan, Ruifang
    Ramage, Robert
    Wang, Dongli
    Zhou, Junqiang
    She, Jianwen
    [J]. TALANTA, 2012, 93 : 383 - 391
  • [7] Fast and Simultaneous Determination of Urinary 8-Hydroxy-2′-deoxyguanosine and Ten Monohydroxylated Polycyclic Aromatic Hydrocarbons by Liquid Chromatography/Tandem Mass Spectrometry
    Fan, Ruifang
    Wang, Dongli
    Ramage, Robert
    She, Jianwen
    [J]. CHEMICAL RESEARCH IN TOXICOLOGY, 2012, 25 (02) : 491 - 499
  • [8] Simultaneous determination of 12 monohydroxylated polycyclic aromatic hydrocarbon metabolites in human urine by ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry
    Fu Hui
    Hu Xiaojian
    Chen Xi
    Lin Shaobin
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2018, 36 (05) : 487 - 492
  • [9] A novel high-throughput method for supported liquid extraction of retinol and alpha-tocopherol from human serum and simultaneous quantitation by liquid chromatography tandem mass spectrometry
    Hinchliffe, Edward
    Rudge, James
    Reed, Paul
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2016, 53 (04) : 434 - 445
  • [10] Determination of phenolic metabolites of polycyclic aromatic hydrocarbons in human urine as their pentafluorobenzyl ether derivatives using liquid chromatography-tandem mass spectrometry
    Jacob, Peyton, III
    Wilson, Margaret
    Benowitz, Neal L.
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (02) : 587 - 598