Studies in Fat Grafting: Part II. Effects of Injection Mechanics on Material Properties of Fat

被引:25
|
作者
Atashroo, David
Raphel, Jordan
Chung, Michael T.
Paik, Kevin J.
Parisi-Amon, Andreina
McArdle, Adrian
Senarath-Yapa, Kshemendra
Zielins, Elizabeth R.
Tevlin, Ruth
Duldulao, Chris
Walmsley, Graham G.
Hu, Michael S.
Momeni, Arash
Domecus, Brian
Rimsa, Joe R.
Greenberg, Lauren
Gurtner, Geoffrey C.
Longaker, Michael T.
Wan, Derrick C.
机构
[1] Stanford Univ, Hagey Lab Pediat Regenerat Med, Dept Surg, Plast & Reconstruct Surg Div,Sch Med, Stanford, CA 94305 USA
[2] Stanford Univ, Sch Med, Inst Stem Cell Biol & Regenerat Med, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Mat Sci & Engn, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[5] Tau Tona Grp, Menlo Pk, CA USA
[6] Plast Surg Ctr Palo Alto, Palo Alto, CA USA
基金
美国国家卫生研究院;
关键词
VISCOELASTIC PROPERTIES; ADIPOCYTE VIABILITY; ADIPOSE-TISSUE; LIPOSUCTION; RELAXATION; PRESSURE; HARVEST; SHEAR;
D O I
10.1097/PRS.0000000000000289
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Although fat grafting can address many soft-tissue deficits, results remain inconsistent. In this study, the authors compared physical properties of fat following injection using an automated, low-shear device or the modified Coleman technique. Methods: Lipoaspirate was obtained from nine patients and processed for injection using either a modified Coleman technique or an automated, low-shear device. Fat was passed through a 2-mm cannula and compared with minimally processed fat. A rheometer was used to measure the storage modulus and shear rate at which tissues began to lose their solid-like properties. Viscosity was also measured, and gross properties of treatment groups were evaluated qualitatively with a glass slide test. Results: Fat injected through an automated, low-shear device closely matched physical properties of minimally processed fat. The storage modulus (G') of fat for the device group was greater than for the modified Coleman group, and the onset of breakdown was delayed. Similarly, viscosity measurement of fat from the automated device closely matched minimally processed fat and was greater than that of othe modified Coleman group. Conclusions: The physical properties of lipoaspirate processed using an automated, low-shear device with a 2-mm cannula preserved the intactness of fat more than the modified Coleman technique. The authors' rheologic data demonstrate less damage using an automated device compared with the modified Coleman technique and potentially support its use for improved fat graft integrity.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 50 条
  • [1] Studies in Fat Grafting: Part I. Effects of Injection Technique on In Vitro Fat Viability and In Vivo Volume Retention; and Studies in Fat Grafting: Part II. Effects of Injection Mechanics on Material Properties of Fat
    Jia, Yihong
    Yu, Nanze
    Wang, Yang
    Zeng, Ang
    Zhu, Lin
    Wang, Xiaojun
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2015, 135 (02) : 446E - 447E
  • [2] Reply: Studies in Fat Grafting: Part I. Effects of Injection Technique on In Vitro Fat Viability and In Vivo Volume Retention; and Studies in Fat Grafting: Part II. Effects of Injection Mechanics on Material Properties of Fat
    Wan, Derrick C.
    Gurtner, Geoffrey C.
    Longaker, Michael T.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2015, 135 (02) : 448E - 449E
  • [3] Studies in Fat Grafting Part I. Effects of Injection Technique on In Vitro Fat Viability and In Vivo Volume Retention
    Hwang, Kun
    Hong, Jung Ui
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2015, 135 (01) : 227E - 228E
  • [4] Studies in Fat Grafting: Part I. Effects of Injection Technique on In Vitro Fat Viability and In Vivo Volume Retention
    Chung, Michael T.
    Paik, Kevin J.
    Atashroo, David A.
    Hyun, Jeong S.
    McArdle, Adrian
    Senarath-Yapa, Kshemendra
    Zielins, Elizabeth R.
    Tevlin, Ruth
    Duldulao, Chris
    Hu, Michael S.
    Walmsley, Graham G.
    Parisi-Amon, Andreina
    Momeni, Arash
    Rimsa, Joe R.
    Commons, George W.
    Gurtner, Geoffrey C.
    Wan, Derrick C.
    Longaker, Michael T.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 134 (01) : 29 - 38
  • [5] Studies in Fat Grafting: Part III. Fat Grafting Irradiated Tissue-Improved Skin Quality and Decreased Fat Graft Retention
    Garza, Rebecca M.
    Paik, Kevin J.
    Chung, Michael T.
    Duscher, Dominik
    Gurtner, Geoffrey C.
    Longaker, Michael T.
    Wan, Derrick C.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 134 (02) : 249 - 257
  • [7] Effects of sorbent injection on particulate properties: Part II. High temperature sorbent injection
    Dahlin, R.S.
    Snyder, T.R.
    Bush, P.V.
    Journal of the Air and Waste Management Association, 1993, 43 (01): : 91 - 96
  • [8] Megavolume Autologous Fat Transfer: Part II. Practice and Techniques
    Khouri, Roger K.
    Rigotti, Gino
    Cardoso, Eufemiano
    Khouri, Roger K., Jr.
    Biggs, Thomas M.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 133 (06) : 1369 - 1377
  • [9] Studies in the secretion of milk fat II. The effect of inanition on the yield and composition of milk fat
    Smith, JAB
    Dastur, NN
    BIOCHEMICAL JOURNAL, 1938, 32 : 1868 - 1876
  • [10] On the nature of the fat contained in the liver, kidney and heart. Part II.
    Hartley, P
    JOURNAL OF PHYSIOLOGY-LONDON, 1909, 38 (05): : 353 - 374