Transient Stability Analysis of Direct Drive Wind Turbine in DC-Link Voltage Control Timescale during Grid Fault

被引:5
作者
Hu, Qi [1 ]
Xiong, Yiyong [1 ]
Liu, Chenruiyang [1 ]
Wang, Guangyu [1 ]
Ma, Yanhong [1 ]
机构
[1] Naval Univ Engn, Sch Elect Engn, Natl Key Lab Sci & Technol Vessel Integrated Powe, Wuhan 430033, Peoples R China
基金
中国国家自然科学基金;
关键词
direct drive wind turbine; grid fault; nonlinear oscillation; transient stability; time-frequency analysis; transient switch; PLL-BASED VSC; SIGNAL; DYNAMICS; IMPACT;
D O I
10.3390/pr10040774
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Transient stability during grid fault is experienced differently in modern power systems, especially in wind-turbine-dominated power systems. In this paper, transient behavior and stability issues of a direct drive wind turbine during fault recovery in DC-link voltage control timescale are studied. First, the motion equation model that depicts the phase and amplitude dynamics of internal voltage driven by unbalanced active and reactive power is developed to physically depict transient characteristics of the direct drive wind turbine itself. Considering transient switch control induced by active power climbing, the two-stage model is employed. Based on the motion equation model, transient behavior during fault recovery in a single machine infinite bus system is studied, and the analysis is also divided into two stages: during and after active power climbing. During active power climbing, a novel approximate analytical expression is proposed to clearly reveal the frequency dynamics of the direct drive wind turbine, which is identified as approximate monotonicity at excitation of active power climbing. After active power climbing, large-signal oscillation behavior is concerned. A novel analysis idea combining time-frequency analysis based on Hilbert transform and high order modes is employed to investigate and reveal the nonlinear oscillation, which is characterized by time-varying oscillation frequency and amplitude attenuation ratio. It is found that the nonlinear oscillation and even stability are related closely to the final point during active power climbing. With a large active power climbing rate, the nonlinear oscillation may lose stability. Simulated results based on MATLAB (R) are also presented to verify the theoretical analysis.
引用
收藏
页数:20
相关论文
共 34 条
[1]   Identification of instantaneous attributes of torsional shaft signals using the Hilbert transform [J].
Andrade, MA ;
Messina, AR ;
Rivera, CA ;
Olguin, D .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (03) :1422-1429
[2]   Reactive Power Optimization of Large-Scale Power Systems: A Transfer Bees Optimizer Application [J].
Cao, Huazhen ;
Yu, Tao ;
Zhang, Xiaoshun ;
Yang, Bo ;
Wu, Yaxiong .
PROCESSES, 2019, 7 (06)
[3]  
[陈骁 Chen Xiao], 2019, [中国电机工程学报, Proceedings of the Chinese Society of Electrical Engineering], V39, P2625
[4]   Actuator and Sensor Fault Classification for Wind Turbine Systems Based on Fast Fourier Transform and Uncorrelated Multi-Linear Principal Component Analysis Techniques [J].
Fu, Yichuan ;
Gao, Zhiwei ;
Liu, Yuanhong ;
Zhang, Aihua ;
Yin, Xiuxia .
PROCESSES, 2020, 8 (09)
[5]   An Overview on Fault Diagnosis, Prognosis and Resilient Control for Wind Turbine Systems [J].
Gao, Zhiwei ;
Liu, Xiaoxu .
PROCESSES, 2021, 9 (02) :1-19
[6]   Input-admittance calculation and shaping for controlled voltage-source converters [J].
Harnefors, Lennart ;
Bongiorno, Massimo ;
Lundberg, Stefan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (06) :3323-3334
[7]   Transient Stability Analysis and Enhancement of Renewable Energy Conversion System During LVRT [J].
He, Xiuqiang ;
Geng, Hua ;
Li, Ruiqi ;
Pal, Bikash Chandra .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2020, 11 (03) :1612-1623
[8]   Modeling of DFIG-Based WTs for Small-Signal Stability Analysis in DVC Timescale in Power Electronized Power Systems [J].
Hu, Jiabing ;
Yuan, Hao ;
Yuan, Xiaoming .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2017, 32 (03) :1151-1165
[9]   Small Signal Instability of PLL-Synchronized Type-4 Wind Turbines Connected to High-Impedance AC Grid During LVRT [J].
Hu, Jiabing ;
Hu, Qi ;
Wang, Bo ;
Tang, Haiyan ;
Chi, Yongning .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) :1676-1687
[10]  
[胡祺 Hu Qi], 2021, [中国电机工程学报, Proceedings of the Chinese Society of Electrical Engineering], V41, P98