Clocking effect of outlet RGVs on hydrodynamic characteristics in a centrifugal pump with an inlet inducer by CFD method

被引:29
|
作者
Zhang, Xiang-Yuan [1 ]
Jiang, Chen-Xing [1 ]
Lv, Shen [1 ]
Wang, Xi [1 ]
Yu, Tao [1 ]
Jian, Jie [1 ]
Shuai, Zhi-Jun [1 ]
Li, Wan-You [1 ]
机构
[1] Harbin Engn Univ, Coll Power & Energy Engn, Harbin, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Clocking effect; centrifugal pump; radial guide vane; inlet inducer; pressure fluctuation; hydraulic performance; VANE CLOCKING; PERFORMANCE; OPTIMIZATION; COMPRESSOR; CAVITATION; EFFICIENCY; HEAT;
D O I
10.1080/19942060.2021.1871961
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper investigates the hydrodynamic characteristic of a single-stage centrifugal pump with inlet inducer and outlet Radial Guided Vanes (RGVs) influenced by the clocking effect for the first time. Different from general ones, the outlet RGVs in this paper have specificities. The hydraulic performance and dynamic characteristics of the centrifugal pump are numerically studied and validated by experiments. The results indicate that there is an optimum position of RGVs that can not only increase the pump head and efficiency but also reduce the pressure fluctuation intensity. A non-dimensional parameter describing the velocity non-uniformity of the impeller outlet is first proposed, which is negatively related to the pump's hydraulic performance. The clocking position of the RGVs will affect the velocity homogeneity at the impeller outlet, and further influence the hydraulic characteristics of the pump. Besides, the clocking effect of outlet RGVs mainly affects the amplitudes of BPF for both the pressure fluctuation and radial force, and the most obvious frequency of pressure pulsation and radial force is 3 BPF correlating with the inlet inducer. It is recommended to install the volute-tongue tip near the middle of two vanes.
引用
收藏
页码:222 / 235
页数:14
相关论文
共 50 条
  • [1] Effect of clocking position of inducer on hydraulic characteristics of centrifugal pump
    Lu, Jinling
    Deng, Jia
    Xu, Yirong
    Feng, Jianjun
    Luo, Xingqi
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2015, 31 (19): : 54 - 60
  • [2] CFD calculation of clocking effect on centrifugal pump
    Liu, Houlin
    Cui, Jianbao
    Tan, Minggao
    Wu, Xianfang
    Xu, Huan
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2013, 29 (14): : 67 - 73
  • [3] INFLUENCE OF INLET AND OUTLET ANGLES OF INDUCER ON IMPROVEMENT IN SUCTION PERFORMANCE OF CENTRIFUGAL PUMP.
    Tahara, Haruo
    Manabe, Akira
    1600, (50):
  • [4] Numerical investigation of clocking effect on a centrifugal pump with inlet guide vanes
    Qu, Wanshi
    Tan, Lei
    Cao, Shuliang
    Wang, Yuchuan
    Xu, Yun
    ENGINEERING COMPUTATIONS, 2016, 33 (02) : 465 - 481
  • [5] Clocking effect in a centrifugal pump with a vaned diffuser
    Lai, Fen
    Zhu, Xiangyuan
    Duan, Yongqiang
    Li, Guojun
    MODERN PHYSICS LETTERS B, 2020, 34 (26):
  • [6] Entropy production analysis for the clocking effect between inducer and impeller in a high-speed centrifugal pump
    Yang, Baofeng
    Li, Bin
    Chen, Hui
    Liu, Zhanyi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2019, 233 (15) : 5302 - 5315
  • [7] Effects of Twisted and Cylindrical Blades on the Flow Characteristics inside Blade Inlet and Outlet for a Centrifugal Pump
    Deng, Xin
    Yuan, Shouqi
    Si, Qiaorui
    Yuan, Jianping
    Zhang, Jinfeng
    CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 645 - 650
  • [8] Effect of Inlet Conditions on Centrifugal Pump Performance
    Aissa, W. A.
    INTERNATIONAL JOURNAL OF FLUID MECHANICS RESEARCH, 2009, 36 (02) : 97 - 113
  • [9] Effect of circumferential outlet distortion on the flow characteristics at the impeller exit of a centrifugal pump
    Hong, SS
    Kang, SH
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2001, 215 (09) : 1083 - 1093
  • [10] Experimental test on impeller clocking effect in a multistage centrifugal pump
    Tan, Minggao
    He, Naichang
    Liu, Houlin
    Wu, Xianfang
    Ding, Jian
    ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (04) : 1 - 10