Anterior segment angiography of the normal canine eye: A comparison between indocyanine green and sodium fluorescein

被引:10
|
作者
Pirie, C. G. [1 ]
Alario, A. [1 ]
机构
[1] Tufts Univ, Cummings Sch Vet Med, Dept Clin Sci, North Grafton, MA 01536 USA
来源
VETERINARY JOURNAL | 2014年 / 199卷 / 03期
关键词
Anterior segment; Canine; Indocyanine green; Iris; Sodium fluorescein; SYSTEMIC-LUPUS-ERYTHEMATOSUS; STABILIZATION; FUNDUS; IRIS; DYE;
D O I
10.1016/j.tvjl.2013.12.011
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The objective of this study was to assess and compare indocyanine green (IG) and sodium fluorescein (SF) angiographic findings in the normal canine anterior segment using a digital single lens reflex (dSLR) camera adaptor. Images were obtained from 10 brown-eyed Beagles, free of ocular and systemic disease. All animals received butorphanol (0.2 mg/kg IM), maropitant citrate (1.0 mg/kg SC) and diphenhydramine (2.0 mg/kg SC) 20 min prior to propofol (4 mg/Kg IV bolus, 0.2 mg/kg/min continuous rate infusion). Standard color imaging was performed prior to the administration of 0.25% IC (1 mg/kg IV). Imaging was performed using a full spectrum dSLR camera, dSLR camera adaptor, camera lens (Canon 60 mm f/2.8 Macro) and an accessory flash. Images were obtained at a rate of 1/s immediately following IG bolus for 30 s, then at 1, 2, 3, 4 and 5 min. Ten minutes later, 10% SF (20 mg/kg IV) was administered. Imaging was repeated using the same adaptor system and imaging sequence protocol. Arterial, capillary and venous phases were identified during anterior segment IC angiography (ASIGA) and their time sequences were recorded. ASIGA offered improved visualization of the iris vasculature in heavily pigmented eyes compared to anterior segment SF angiography (ASSFA), since visualization of the vascular pattern during ASSFA was not possible due to pigment masking. Leakage of SF was noted in a total of six eyes. The use of IG and SF was not associated with any observed adverse events. The adaptor described here provides a cost-effective alternative to existing imaging systems. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:360 / 364
页数:5
相关论文
共 50 条
  • [1] Use of indocyanine green and sodium fluorescein for anterior segment angiography in ophthalmologically normal cats
    Pirie, Chris G.
    Alario, Anthony
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2015, 76 (10) : 897 - 903
  • [2] Comparison between indocyanine green angiography and fluorescein angiography in normal cats
    Hayashi, Miri
    Maehara, Seiya
    Ito, Yosuke
    Yamashita, Kazuto
    Kubo, Akira
    Nakade, Tetsuya
    VETERINARY OPHTHALMOLOGY, 2017, 20 (04) : 310 - 315
  • [3] Anterior segment fluorescein angiography of the normal canine eye using a dSLR camera adaptor
    Alario, Anthony F.
    Pirie, Christopher G.
    Pizzirani, Stefano
    VETERINARY OPHTHALMOLOGY, 2013, 16 (01) : 10 - 19
  • [4] The value of combining anterior segment fluorescein angiography with indocyanine green angiography in scleral inflammation
    Nieuwenhuizen, J
    Watson, PG
    Jager, MJ
    Emmanouilidis-van der Spek, K
    Keunen, JEE
    OPHTHALMOLOGY, 2003, 110 (08) : 1653 - 1666
  • [5] FLUORESCEIN ANGIOGRAPHY OF ANTERIOR SEGMENT OF EYE
    FAGGIONI, R
    GRONAUER, PA
    GAILLOUD, C
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1976, 168 (01) : 94 - 97
  • [6] INJECTION TECHNIQUE FOR INDOCYANINE GREEN AND SODIUM FLUORESCEIN DYE ANGIOGRAPHY OF EYE
    FLOWER, RW
    INVESTIGATIVE OPHTHALMOLOGY, 1973, 12 (12): : 881 - 895
  • [7] FLUORESCENT VESICLE ANGIOGRAPHY WITH SODIUM FLUORESCEIN AND INDOCYANINE GREEN
    PEYMAN, GA
    MOSHFEGHI, A
    MOSHFEGHI, DM
    KHOOBEHI, B
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S1040 - S1040
  • [8] Comparison of indocyanine green and sodium fluorescein for anterior segment angiography of ophthalmically normal eyes of goats, sheep, and alpacas performed with a digital single-lens reflex camera adaptor
    LoPinto, Alexander J.
    Pirie, Chris G.
    Ayres, Sandra L.
    Bedenice, Daniela
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2017, 78 (03) : 311 - 320
  • [9] Fluorescent vesicle angiography with sodium fluorescein and indocyanine green
    Peyman, GA
    Moshfeghi, DM
    Moshfeghi, AA
    Khoobehi, B
    OPHTHALMIC SURGERY AND LASERS, 1996, 27 (04): : 279 - 284
  • [10] NEW APPARATUS FOR FLUORESCEIN ANGIOGRAPHY OF ANTERIOR SEGMENT OF EYE
    EDWARDS, J
    JOURNAL OF PHYSIOLOGY-LONDON, 1975, 246 (02): : P39 - P40