Discarding the Initial Aliquot of Blood Does Not Reduce Contamination Rates in Intravenous-Catheter-Drawn Blood Cultures

被引:14
|
作者
Dwivedi, Sukrut [1 ]
Bhalla, Rohit [1 ]
Hoover, Donald R. [1 ,3 ]
Weinstein, Melvin P. [1 ,2 ]
机构
[1] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Div Infect Dis Allergy & Immunol, Dept Med, New Brunswick, NJ 08901 USA
[2] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Dept Pathol, New Brunswick, NJ 08901 USA
[3] Rutgers State Univ, Dept Stat & Biostat, New Brunswick, NJ 08903 USA
关键词
HOSPITALIZED-PATIENTS; HEPARIN; TESTS;
D O I
10.1128/JCM.00292-09
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Although venipuncture is the preferred method for obtaining blood cultures, specimens often are obtained from intravenous catheters (IVC). For IVC-drawn blood cultures, some authorities recommend discarding the initial 5 to 10 ml of blood to reduce contamination and remove potential inhibitory substances. To determine whether this practice reduced contamination rates (CR), we assessed the results of IVC-drawn blood cultures for adults. Thirty milliliters of blood was obtained aseptically. The first 10 ml, rather than being discarded, was inoculated into an aerobic culture vial. Using a second sterile syringe, 20 ml of blood was obtained and inoculated in 10-ml aliquots to aerobic and anaerobic culture vials. Positive cultures were evaluated to assess clinical significance ( true versus contaminant). Out of 653 IVC-drawn blood culture pairs, both vials were contaminated in 38 pairs (5.8%); only the "discard" vial was contaminated in 33 (5.1%); and only the "standard" vial was contaminated in 31 (4.7%). Overall CR were 10.9% for the discard vial versus 10.5% for the standard vial (P = 0.90). We conclude that discarding an initial aliquot of blood when obtaining blood cultures from IVCs does not reduce CR.
引用
收藏
页码:2950 / 2951
页数:2
相关论文
共 50 条
  • [1] Comparison of contamination rates of catheter-drawn and peripheral blood cultures
    McBryde, ES
    Tilse, M
    McCormack, J
    JOURNAL OF HOSPITAL INFECTION, 2005, 60 (02) : 118 - 121
  • [2] Contamination of catheter-drawn blood cultures
    Everts, RJ
    Vinson, EN
    Adholla, PO
    Reller, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (09) : 3393 - 3394
  • [3] Contamination of catheter-drawn blood cultures
    Casey, A. L.
    Elliott, T. S. J.
    CLINICAL MICROBIOLOGY AND INFECTION, 2007, 13 (01) : 110 - 111
  • [4] Intravenous catheter blood cultures: Utility and contamination
    McQuillen, KK
    Santucci, KA
    Conrad, MA
    Nelson, DG
    Lewander, W
    Duffy, SJ
    Anderson, AC
    PEDIATRICS, 1999, 103 (04) : art. no. - e52
  • [5] Contamination Rates of Two Blood Cultures Drawn Through the Same Intravenous Line • 385
    Kemedy K McQuillen
    Karen A Santucci
    Margaret Conrad
    Angela C Anderson
    William J Lewander
    Susan J Duffy
    Pediatric Research, 1998, 43 (Suppl 4) : 68 - 68
  • [6] Contamination rates of blood cultures obtained by dedicated phlebotomy vs intravenous catheter
    Norberg, A
    Christopher, NC
    Ramundo, ML
    Bower, JR
    Berman, SA
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 289 (06): : 726 - 729
  • [7] EVALUATION OF THE RESULTS OF BLOOD CULTURES DRAWN FROM THE INTRAVENOUS CATHETER IN GRANULOCYTOPENIC PATIENTS
    GUIOT, HFL
    HELMIGSCHURTER, AV
    BONE MARROW TRANSPLANTATION, 1988, 3 : 321 - 321
  • [8] Should Blood Cultures Be Drawn Through an Indwelling Catheter?
    Mermel, Leonard A.
    Rupp, Mark E.
    OPEN FORUM INFECTIOUS DISEASES, 2024, 11 (05):
  • [9] A blood culture sampling protocol does not reduce the incidence of inappropriately drawn blood cultures and subsequent vancomycin use
    Dudas, VJ
    Tokumaru, S
    Jacobs, R
    Guglielmo, BJ
    CLINICAL INFECTIOUS DISEASES, 2000, 31 (01) : 291 - 291
  • [10] Taking blood cultures from a newly established intravenous catheter in the emergency department does not increase the rate of contaminated blood cultures
    Kelly, Anne-Maree
    Klim, Sharon
    EMERGENCY MEDICINE AUSTRALASIA, 2013, 25 (05) : 435 - 438