Analytical and Clinical Performance of Kroma iT, A Compact Fully-automated Immunochemistry Analyzer for Fecal Occult Hemoglobin

被引:0
|
作者
Auge, Josep M. [1 ]
Rodriguez, Cristina [2 ]
Pellise, Maria [2 ]
Bernal, Ana [1 ]
Grau, Jaume [3 ]
Castells, Antoni [2 ]
Filella, Xavier [1 ]
Molina, Rafael [1 ]
机构
[1] Hosp Clin Barcelona, IDIBAPS, Dept Biochem & Mol Genet, E-08036 Barcelona, Spain
[2] Hosp Clin Barcelona, IDIBAPS, Dept Gastroenterol, E-08036 Barcelona, Spain
[3] Hosp Clin Barcelona, IDIBAPS, Unit Evaluat Support & Prevent, E-08036 Barcelona, Spain
关键词
Colorectal cancer; fecal occult hemoglobin; analyzer evaluation; Kroma iT; COLORECTAL-CANCER; BLOOD-TESTS; AVERAGE RISK;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: We performed a laboratory and clinical evaluation of Kroma iT (Linear Chemicals S.L), an immunoturbidimetric analyzer for the detection of fecal occult blood. Materials and Methods: After a familiarization period, the imprecision, linearity of dilution and carry-over were determined and a clinical evaluation was performed on 210 patients. Results: Within-run imprecision ranged between 1.06% and 8.04%. Between-run imprecision ranged between 3.11% and 13.09%. Linearity of dilution revealed a mean recovery of all dilutions of 95.24%, with a standard deviation of 7.47%. No carry-over was detected. The clinical evaluation demonstrated that the mean hemoglobin levels of the fecal immunochemical test values from patients with advanced neoplasms (colorectal cancer plus advanced adenoma) were significantly higher than those of cases with a normal colonoscopy examination. Sensitivity for advanced neoplasms at cut-off values between 80 and 300 ng/ml (6.4-24 mg Hb/Kg feces) ranged from 45.5% to 36.4% and the specificity ranged from 86.8% to 92.3%. The positive predictive values for detecting colorectal cancer and advanced adenomas were 5.4-6.4% and 27-34% respectively and the negative predictive value ranged from 92.5% to 91.7%. Using two samples per patient, a substantial increase of sensitivity was observed, with only a slight decrease in specificity. Conclusion: Kroma iT analyzer is easy to handle and safe for personnel to use. Its analytical and clinical performance makes it suitable for use in a clinical chemistry laboratory for the early detection of advanced neoplasms.
引用
收藏
页码:5633 / 5637
页数:5
相关论文
共 23 条
  • [1] Analytical and clinical performance of the fully-automated LIAISONXL calprotectin immunoassay from DiaSorin in IBD patients
    Vicente-Steijn, R.
    Jansen, J. M.
    Bisheshar, R.
    Haagen, I. -A.
    PRACTICAL LABORATORY MEDICINE, 2020, 21
  • [2] Development of novel and fully-automated clinical laboratory analyzer: the STACIA TM system.
    Yamagishi, T.
    Yokota, K.
    Goukura, A.
    Inoue, A.
    Shintani, E.
    Ootake, K.
    Shimada, R.
    Fudou, R.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A200 - A200
  • [3] Analytical and clinical performance of an automated assay for the measurement of osteocalcin on the LIAISON® analyzer
    Podgorski, A. L.
    Vaught, D. L.
    Body, J. J.
    Vertongen, F.
    Olson, G. T.
    Blocki, F. A.
    Schmidt, J. A.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 : S415 - S415
  • [4] ANALYTICAL AND CLINICAL PERFORMANCE OF AUTOMATED IMMUNOTURBIDIMETRIC ASSAY FOR DETECTING FECAL CALPROTECTIN
    Wang, Tieshan
    Shi, Haiyun
    GUT, 2021, 70 : A109 - A109
  • [5] Analytical performance of new and quantitative assays for the diagnosis of antiphospholipid syndrome on a fully automated, chemiluminescent analyzer
    Morin, K. A.
    Barry, R. G.
    Guasch, J. F.
    Ruiz, N.
    Puig, J.
    Musial, J.
    Arnout, J.
    Reber, G.
    de Moerloose, P.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 718 - 718
  • [6] ANALYTICAL PERFORMANCE AND CLINICAL UTILITY OF ITACT-HBCRAG ASSAY FOR FULLY AUTOMATED ANALYZER LUMIPULSE® L2400 WITH AUTOMATED PRETREATMENT PROCESS.
    Kitamura, Yoshiyuki
    Mori, Takaaki
    Ohue, Chiharu
    Aoyagi, Katsumi
    Yagi, Shintaro
    HEPATOLOGY, 2021, 74 : 428A - 428A
  • [7] Clinical Performance Study of a New Fully Automated Red Blood Cell Permeability Fragility Analyzer
    Zheng, Shiwen
    Li, Qiuyan
    Ou, Tong
    Li, Yuqing
    Wu, Song
    JOURNAL OF HEALTHCARE ENGINEERING, 2022, 2022
  • [8] Analytical evaluation of three enzymatic assays for measuring total bile acids in plasma using a fully-automated clinical chemistry platform
    Danese, Elisa
    Salvagno, Gian Luca
    Negrini, Davide
    Brocco, Giorgio
    Montagnana, Martina
    Lippi, Giuseppe
    PLOS ONE, 2017, 12 (06):
  • [9] Clinical performance of new and quantitative assays for the diagnosis of antiphospholipid syndrome (APS) on a fully automated, chemiluminescent analyzer
    Serra, J.
    Barry, R. G.
    Morin, K. A.
    Manion, C., V
    Musial, J.
    Arnout, J.
    Van Russelt, M.
    de Moerloose, P.
    Reber, G.
    Ruiz, N.
    Puig, J.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 717 - 717
  • [10] Evaluation of the Analytical Performance of the Fully Automated Gene Analyzer μTASWako g1 for the Detection of SARS-CoV-2
    Toda, Hirofumi
    Tanaka, Yuji
    Yamade, Kenji
    Tsujimoto, Mayu
    Takada, Haruka
    Ueno, Minoru
    Tsuda, Yoshihiro
    Kishino, Yoshizumi
    Kubo, Shuichi
    Kamisako, Toshinori
    Yoshida, Koichiro
    CLINICAL LABORATORY, 2023, 69 (02) : 425 - 429