Electroanatomic mapping of the right atrium with a right atrial basket catheter and three-dimensional intracardiac echocardiography

被引:8
|
作者
Simon, RDB [1 ]
Rinaldi, CA [1 ]
Baszko, A [1 ]
Gill, JS [1 ]
机构
[1] Guys & St Thomas Hosp NHS Trust, Dept Adult Cardiol, London, England
来源
关键词
electroanatomic; mapping; isochronal; basket catheter; three-dimensional intracardiac echocardiography; atrial flutter;
D O I
10.1111/j.1540-8159.2004.00435.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The ablation of arrhythmias progresses towards an approach based upon application of linear lesions between nonconducting anatomic/electrical areas. Hence the identification of detailed anatomy together with electrical behavior becomes increasingly important. This study aims to achieve true electroanatomic mapping by the use of three-dimensional intracardiac imaging of the right atrium combined with use of a right atrial basket to obtain detailed electrical information. We studied nine patients, seven requiring atrial flutter ablation. A 9 Fr, 9 MHZ intracardiac echo catheter was pulled back from SVC to IVC using respiratory and ECG gating. The images, recorded on a Clearview ultrasound machine, were reconstructed using commercially available software. The intracardiac basket was placed into the atrium using the markers and fluoroscopy to allow orientation. Isochronal maps were obtained from the basket in sinus rhythm, pacing from different sites within the atrium and in atrial flutter. Isochronal maps were constructed and superimposed on the ICE image. The maps with pacing were consistent with that which was expected, confirming the validity of this approach. We were able to visualize changes in activation sequence following the placement of bidirectional isthmus block. True electroanatomic mapping is possible by the use of three-dimensional ICE reconstruction of the right atrium with electrical activation obtained from an intracardiac basket. This has significance for anatomically based arrhythmia ablations such as the ablation of atrial flutter, atrial fibrillation, with transcatheter MAZE procedures and pulmonary vein isolation. Further developments in software will allow such maps to be produced simultaneously with greater rapidity.
引用
收藏
页码:318 / 326
页数:9
相关论文
共 50 条
  • [1] True electroanatomical mapping obtained by the use of a right atrial basket catheter and three-dimensional intracardiac echocardiography
    Simon, RDB
    Rinaldi, A
    Ward, K
    Gill, JS
    EUROPEAN HEART JOURNAL, 2001, 22 : 691 - 691
  • [2] Three-dimensional mapping of the common atrial flutter circuit in the right atrium
    Shah, DC
    Jais, P
    Haissaguerre, M
    Chouairi, S
    Takahashi, A
    Hocini, M
    Garrigue, S
    Clementy, J
    CIRCULATION, 1997, 96 (11) : 3904 - 3912
  • [3] Three-dimensional electromagnetic catheter technology: Electroanatomical mapping of the right atrium and ablation of ectopic atrial tachycardia
    Kottkamp, H
    Hindricks, G
    Breithardt, G
    Borggrefe, M
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (12) : 1332 - 1337
  • [4] A case of catheter ablation of accessory atrioventricular connection between the right atrial appendage and right ventricle guided by a three-dimensional electroanatomic mapping system
    Goya, M
    Takahashi, A
    Nakagawa, H
    Iesaka, Y
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (08) : 1112 - 1118
  • [5] Intracardiac echocardiography and electroanatomic mapping in diagnosis of arrhythmogenic right ventricular dysplasia
    Ficili, Sabina
    Pandozi, Claudio
    Russo, Maurizio
    Dottori, Serena
    Cina, Alessandro
    Natale, Luigi
    Lavalle, Carlo
    Galeazzi, Marco
    Santini, Massimo
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2010, 11 (01) : 59 - 60
  • [6] Anatomical site of catheter placement and tissue contact assessed by means of three-dimensional intracardiac echocardiography in right atrial catheter MAZE procedures
    Simon, RDB
    Rinaldi, A
    Gill, JS
    Baszko, A
    EUROPEAN HEART JOURNAL, 2001, 22 : 136 - 136
  • [7] Three-Dimensional Electroanatomic Mapping Systems in Catheter Ablation of Atrial Fibrillation
    Lo, Li-Wei
    Chen, Shih-Ann
    CIRCULATION JOURNAL, 2010, 74 (01) : 18 - 23
  • [8] Three-dimensional echocardiography of the right atrial embryonic remnants
    Roldán, FJ
    Vargas-Barrón, J
    Espinola-Zavaleta, N
    Romero-Cárdenas, A
    Vázquez-Antona, C
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (01): : 99 - +
  • [9] Three-dimensional non-contact mapping of the right atrium during right and left atrial initiation of spontaneous atrial fibrillation
    Saksena, S
    Filipecki, A
    Prakash, A
    Krol, R
    Philip, G
    EUROPEAN HEART JOURNAL, 2001, 22 : 336 - 336
  • [10] True electro-anatomical mapping achieved by the simultaneous use of a right atrial basket catheter and 3D intracardiac echocardiography
    Simon, RDB
    Razavi, R
    Miquel, M
    Baszko, A
    Baker, EJ
    Gill, JS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 426A - 426A