Multi-Modality Phantom Development

被引:18
|
作者
Huber, Jennifer S. [1 ]
Peng, Qiyu [1 ]
Moses, William W. [1 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
关键词
Magnetic resonance imaging; positron emission tomography; ultrasound; x-ray computed tomography; ACOUSTIC PROPERTIES; MIMICKING;
D O I
10.1109/TNS.2009.2028073
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Multi-modality imaging has an increasing role in the diagnosis and treatment of a large number of diseases, particularly if both functional and anatomical information are acquired and accurately co-registered. Hence, there is a resulting need for multi-modality phantoms in order to validate image co-registration and calibrate the imaging systems. We present our PET-ultrasound phantom development, including PET and ultrasound images of a simple prostate phantom. We use agar and gelatin mixed with a radioactive solution. We also present our development of custom multi-modality phantoms that are compatible with PET, transrectal ultrasound (TRUS), MRI and CT imaging. We describe both our selection of tissue mimicking materials and phantom construction procedures. These custom PET-TRUS-CT-MRI prostate phantoms use agar-gelatin radioactive mixtures with additional contrast agents and preservatives. We show multi-modality images of these custom prostate phantoms, as well as discuss phantom construction alternatives. Although we are currently focused on prostate imaging, this phantom development is applicable to many multi-modality imaging applications.
引用
收藏
页码:2722 / 2727
页数:6
相关论文
共 50 条
  • [1] Multi-modality phantom development
    Huber, J. S.
    Peng, Q.
    Moses, W. W.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2944 - 2948
  • [2] Development of An Original Multi-Modality Gynecologic Brachytherapy Phantom
    Eckroate, B.
    Raffi, J.
    Venkataraman, R.
    Kim, Y.
    Ayala-peacock, D.
    Craciunescu, O.
    MEDICAL PHYSICS, 2022, 49 (06) : E815 - E815
  • [3] Development of a Virtual Breast Phantom From a Multi-Modality Perspective
    Graff, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3715 - 3715
  • [4] Generic Multi-Purpose Multi-Modality Phantom Kit Design
    Heinen, Ulrich
    Franke, Jochen
    Baxan, Nicoleta
    Strobel, Klaus
    Lehr, Heinrich
    Weber, Alexander
    Ruhm, Wolfgang
    Khandhar, Amit P.
    Ferguson, R. Matthew
    Kemp, Scott
    Krishnan, Kannan M.
    Heidenreich, Michael
    2015 5TH INTERNATIONAL WORKSHOP ON MAGNETIC PARTICLE IMAGING (IWMPI), 2015, : P6 - P6
  • [5] End-to-end testing for stereotactic radiotherapy including the development of a MULTI-MODALITY phantom
    Shariff, Maya
    Grigo, Johanna
    Masitho, Siti
    Brandt, Tobias
    Weiss, Alexander
    Lambrecht, Ulrike
    Stillkrieg, Willi
    Lotter, Michael
    Putz, Florian
    Fietkau, Rainer
    Bert, Christoph
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2024, 34 (03): : 477 - 484
  • [6] A Novel Multi-Modality Perfusion Phantom for Nuclear Imaging Studies
    Gabrani-Juma, Hanif
    Clarkin, Owen
    Pourmoghaddas, Amir
    Dekemp, Robert
    Wells, R. Glenn
    Klein, Ran
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [7] Technical note: The design and validation of a multi-modality lung phantom
    Bowen, Donald L.
    Touchet, Tyler J.
    Maitland, Duncan J.
    McDougall, Mary P.
    MEDICAL PHYSICS, 2023, 50 (08) : 4809 - 4815
  • [8] Multi-modality tissue-mimicking phantom for thermal therapy
    McDonald, M
    Lochhead, S
    Chopra, R
    Bronskill, MJ
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13): : 2767 - 2778
  • [9] Development and first implementation of a novel multi-modality cardiac motion and dosimetry phantom for radiotherapy applications
    Gregg, Kenneth W.
    Ruff, Chase
    Koenig, Grant
    Penev, Kalin I.
    Shepard, Andrew
    Kreissler, Grace
    Amatuzio, Margo
    Owens, Cameron
    Nagpal, Prashant
    Glide-Hurst, Carri K.
    MEDICAL PHYSICS, 2024, 51 (10) : 7479 - 7491
  • [10] Error Analysis of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using a Preclinical Multi-Modality QA Phantom
    Lee, Y.
    Fullerton, G.
    Goins, B.
    MEDICAL PHYSICS, 2015, 42 (06) : 3261 - 3261