Current - Voltage Variation and Voltage Stability at Constant Load for a PEMFC System with Different Bipolar Plate Flow Fields

被引:0
|
作者
Ionescu, Viorel [1 ,2 ]
Buzbuchi, Nicolae [3 ]
Andronie, Adriana [4 ]
Stamatin, Ioan [4 ]
Girleanu, Valentin [4 ]
机构
[1] Ovidius Univ, Dept Phys & Elect, Constanta 900527, Romania
[2] Maritime Univ, Doctoral Sch Mech Engn & Mechatron, Constanta 900663, Romania
[3] Maritime Univ, Dept Engn Sci, Constanta 900663, Romania
[4] Univ Bucharest, Fac Phys, 3Nano SAE Res Ctr, Bucharest 077125, Romania
关键词
current load; voltage drop; stoichiometric air ratio; backpressure; serpentine channel; STOICHIOMETRY; BACKPRESSURE; TEMPERATURE; PERFORMANCE;
D O I
10.1109/atee.2019.8724737
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Bipolar plates, as one of the main components of a Proton Exchange Membrane Fuel Cell (PEMFC) system, offer a path for a uniform distribution of reactant gases via flow channels, dissipate heat from reaction sites, prevent leakage of gases and offer the electrical connection between multiple cells in a stack. In this study, a BEKKTECH BT-552 PEMFC test station was used in order to investigate the effect of a three different serpentine-type gas flow fields(M1, M2 and M3) with channel width/channel rib ratios a/w of 1, 1.05 and 1.2 on fuel cell performance at two different system backpressures of 70 kPa and 30 kPa. Cell voltage variations of only 16 mV along a current density step of 0.1 A/cm(2)(at high current densities) have been registered for the fuel unit cell containing flow field M3 with a/w = 1.05 at a backpressure of 70 kPa. The same model presented the highest voltage stability under the test at a constant current load of 0.5 A/cm(2) and at a stoichiometric air ratio of 3.2.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Load Flow Based Voltage Stability Indices to Analyze Voltage Stability and Voltage Security of the Power System
    Telang, A. S.
    Bedekar, P. P.
    2015 5TH NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE), 2015,
  • [2] Experimental Study of a PEMFC System with Different Dimensions of the Serpentine Type Channels from Bipolar Plate Flow Fields
    Andronie, Adriana
    Stamatin, Ioan
    Girleanu, Valentin
    Ionescu, Viorel
    Buzbuchi, Nicolae
    MECHANIKA, 2019, 25 (01): : 11 - 16
  • [3] Voltage stability improvement of a bipolar DC system connected with constant power loads
    Liao, Jianquan
    You, Xiaoyao
    Liu, Heping
    Huang, Yuansheng
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 201
  • [4] A PRECISION CONSTANT CURRENT/VOLTAGE LOAD FOR BATTERY STUDIES
    BARNARTT, S
    MALMBERG, PR
    GOSSER, RB
    ELECTROCHEMICAL TECHNOLOGY, 1965, 3 (11-1): : 327 - &
  • [5] Voltage current characteristics of needle-plate system with different media on the collection plate
    Feng, Zhuangbo
    Long, Zhengwei
    Chen, Qingyan
    JOURNAL OF ELECTROSTATICS, 2014, 72 (02) : 129 - 135
  • [6] Simulation With a Kit to Power System and Load Flow Analysis and Voltage Stability
    Luis, Cisneros-Villalobos
    Oubram, Outmane
    Mario, Limon-Mendoza
    2014 INTERNATIONAL CONFERENCE ON MULTIMEDIA COMPUTING AND SYSTEMS (ICMCS), 2014, : 1495 - 1500
  • [7] Voltage-current characteristics of a pin-plate system with different plate configurations
    Feng, Zhuangbo
    Long, Zhengwei
    7TH INTERNATIONAL CONFERENCE ON APPLIED ELECTROSTATICS (ICAES-2012), 2013, 418
  • [8] Constant Voltage-clamping Bipolar Pulse Current Source for Transient Electromagnetic System
    Zhao, Haitao
    Liu, Lihua
    Wu, Kai
    Qi, Youzheng
    Fang, Guangyou
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (10) : 960 - 971
  • [9] INFLUENCE OF VOLTAGE AND LOAD CURRENT ON DC BIPOLAR CORONA PULSES
    JONSON, ES
    PEDROW, PD
    QIN, BL
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1994, 1 (02) : 284 - 293
  • [10] A PRECISION CONSTANT CURRENT-VOLTAGE LOAD FOR BATTERY STUDIES
    BARNARTT, S
    MALMBERG, PR
    GOSSER, RB
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1964, 111 (08) : C182 - C182