Measurement of renal volumes with contrast-enhanced MRI

被引:63
|
作者
Coulam, CH [1 ]
Bouley, DM [1 ]
Sommer, FG [1 ]
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Sch Med, Stanford, CA 94305 USA
关键词
kidney; MRI; volume; cortex; medulla;
D O I
10.1002/jmri.10058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the accuracy of in vivo magnetic resonance imaging (MRI) measurement of total renal parenchymal volume and medullary fraction. Materials and Methods: Sixteen kidneys in eight pigs were imaged with a multiphasic contrast-enhanced fast three-dimensional sequence on a 1.5-T imager. Kidney segmentation, followed by a process of signal intensity thresholding for cortical and nephrographic phase datasets, allowed for MRI measurements of parenchymal volume and medullary fraction. Autopsy provided reference standards of renal Volume, weight. and medullary fraction. Results: An excellent correlation was found between MRI measurement of total renal parenchymal volume and autopsy volume (R-2 = 0.86) and weight (R-2 = 0.90). Medullary fraction (mean +/- SD) measured with MRI was 0.120 +/- 0.067, and with autopsy was 0.116 +/- 0.025 (t-test P = 0.84, F-test P = 0.001). Conclusion: MRI measurements of total renal volume are accurate. MRI measurements of medullary fraction show promise, but precision is limited when using a simple signal intensity thresholding algorithm.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 50 条
  • [1] Dynamic contrast-enhanced MRI measurement of renal function in healthy participants
    Eikefjord, Eli
    Andersen, Erling
    Hodneland, Erlend
    Hanson, Erik A.
    Sourbron, Steven
    Svarstad, Einar
    Lundervold, Arvid
    Rorvik, Jarle T.
    ACTA RADIOLOGICA, 2017, 58 (06) : 748 - 757
  • [2] Renal and systemic pH imaging by contrast-enhanced MRI
    Raghunand, N
    Howison, C
    Sherry, AD
    Zhang, SR
    Gillies, RJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (02) : 249 - 257
  • [3] Measurement of renal extraction fraction with contrast-enhanced CT
    Sommer, G
    Olcott, EW
    Chow, LC
    Saket, RR
    Schraedley-Desmond, P
    RADIOLOGY, 2005, 236 (03) : 1029 - 1033
  • [4] Texture analysis of lesion perfusion volumes in dynamic contrast-enhanced breast MRI
    Lee, Sang Ho
    Kim, Jong Hyo
    Park, Jeong Seon
    Chang, Jung Min
    Park, Sang Joon
    Jung, Yun Sub
    Tak, Sungho
    Moon, Woo Kyung
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1545 - +
  • [5] In vivo measurement of the thalamic subregions using contrast-enhanced MRI
    Spinks, R
    Harris, G
    Andreasen, NC
    Ziebell, S
    Magnotta, VA
    Cretsinger, K
    Nopolous, P
    NEUROIMAGE, 2001, 13 (06) : S255 - S255
  • [6] Contrast-enhanced MRI of the lung
    Kauczor, HU
    Kreitner, KF
    EUROPEAN JOURNAL OF RADIOLOGY, 2000, 34 (03) : 196 - 207
  • [7] Breast Cancer Supplemental Screening: Contrast-Enhanced Mammography or Contrast-Enhanced MRI?
    Rashidi, Ali
    Lowry, Kathryn P.
    Sadigh, Gelareh
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2024, 21 (04)
  • [8] Contrast-enhanced renal MRA
    Meaney, J.F.M.
    Acta Radiologica Supplementum, 2000, 41 (Suppl 422)
  • [9] Dynamic Contrast-Enhanced Renal MRI at 7 Tesla Preliminary Results
    Umutlu, Lale
    Kraff, Oliver
    Orzada, Stephan
    Fischer, Anja
    Kinner, Sonja
    Maderwald, Stefan
    Antoch, Gerald
    Quick, Harald H.
    Forsting, Michael
    Ladd, Mark E.
    Lauenstein, Thomas C.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (07) : 425 - 433
  • [10] Measurement of Placental Perfusion by Dynamic Contrast-Enhanced MRI at 4.7 T
    Alison, Marianne
    Quibel, Thibault
    Balvay, Daniel
    Autret, Gwennhael
    Bourillon, Camille
    Chalouhi, Gihad E.
    Deloison, Benjamin
    Salomon, Laurent J.
    Cuenod, Charles Andre
    Clement, Olivier
    Siauve, Nathalie
    INVESTIGATIVE RADIOLOGY, 2013, 48 (07) : 535 - 542