A Novel Point-of-Care Smartphone Based System for Monitoring the Cardiac and Respiratory Systems

被引:22
|
作者
Sohn, Kwanghyun [1 ]
Merchant, Faisal M. [2 ]
Sayadi, Omid [1 ]
Puppala, Dheeraj [1 ]
Doddamani, Rajiv [1 ]
Sahani, Ashish [1 ]
Singh, Jagmeet P. [3 ]
Heist, E. Kevin [3 ]
Isselbacher, Eric M. [4 ]
Armoundas, Antonis A. [1 ,5 ]
机构
[1] Massachusetts Gen Hosp, Cardiovasc Res Ctr, Boston, MA 02114 USA
[2] Emory Univ, Sch Med, Div Cardiol, Atlanta, GA 30322 USA
[3] Massachusetts Gen Hosp, Div Cardiol, Cardiac Arrhythmia Serv, Boston, MA 02114 USA
[4] Massachusetts Gen Hosp, Healthcare Transformat Lab, Boston, MA 02114 USA
[5] MIT, Inst Med Engn & Sci, Cambridge, MA 02139 USA
来源
SCIENTIFIC REPORTS | 2017年 / 7卷
关键词
ELECTROCARDIOGRAPHIC SIGNALS IMPLICATIONS; CHEYNE-STOKES RESPIRATION; OBSTRUCTIVE SLEEP-APNEA; OPTIMIZED METHOD; HEART-FAILURE; IMPEDANCE; RISK;
D O I
10.1038/srep44946
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Cardio- respiratory monitoring is one of the most demanding areas in the rapidly growing, mobiledevice, based health care delivery. We developed a 12-lead smartphone-based electrocardiogram ( ECG) acquisition and monitoring system ( called " cvrPhone"), and an application to assess underlying ischemia, and estimate the respiration rate (RR) and tidal volume (TV) from analysis of electrocardiographic (ECG) signals only. During in- vivo swine studies (n = 6), 12-lead ECG signals were recorded at baseline and following coronary artery occlusion. Ischemic indices calculated from each lead showed statistically significant (p < 0.05) increase within 2 min of occlusion compared to baseline. Following myocardial infarction, spontaneous ventricular tachycardia episodes ( n = 3) were preceded by significant ( p < 0.05) increase of the ischemic index 1- 4 min prior to the onset of the tachyarrhythmias. In order to assess the respiratory status during apnea, the mechanical ventilator was paused for up to 2 min during normal breathing. We observed that the RR and TV estimation algorithms detected apnea within 7.9 +/- 1.1 sec and 5.5 +/- 2.2 sec, respectively, while the estimated RR and TV values were 0 breaths/ min and less than 100 ml, respectively. In conclusion, the cvrPhone can be used to detect myocardial ischemia and periods of respiratory apnea using a readily available mobile platform.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A Novel Point-of-Care Smartphone Based System for Monitoring the Cardiac and Respiratory Systems
    Kwanghyun Sohn
    Faisal M. Merchant
    Omid Sayadi
    Dheeraj Puppala
    Rajiv Doddamani
    Ashish Sahani
    Jagmeet P. Singh
    E. Kevin Heist
    Eric M. Isselbacher
    Antonis A. Armoundas
    Scientific Reports, 7
  • [2] Smartphone-based sickle cell disease detection and monitoring for point-of-care settings
    Ilyas, Shazia
    Sher, Mazhar
    Du, E.
    Asghar, Waseem
    BIOSENSORS & BIOELECTRONICS, 2020, 165
  • [3] System Architecture and Security Issues of Smartphone-based Point-Of-Care Devices
    Zajc, Christian
    Holweg, Gerald
    Steger, Christian
    2020 23RD EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN (DSD 2020), 2020, : 320 - 324
  • [4] Point-of-care applications of smartphone-based microscopy
    Ayardulabi, Reyhaneh
    Khamespanah, Erfan
    Abbasinia, Sarv
    Ehtesabi, Hamide
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 331
  • [5] Advances in Smartphone-Based Point-of-Care Diagnostics
    Xu, Xiayu
    Akay, Altug
    Wei, Huilin
    Wang, ShuQi
    Pingguan-Murphy, Belinda
    Erlandsson, Bjoern-Erik
    Li, XiuJun
    Lee, WonGu
    Hu, Jie
    Wang, Lin
    Xu, Feng
    PROCEEDINGS OF THE IEEE, 2015, 103 (02) : 236 - 247
  • [6] Point-of-Care Smartphone-based Electrochemical Biosensing
    Sun, Alexander C.
    Hall, Drew A.
    ELECTROANALYSIS, 2019, 31 (01) : 2 - 16
  • [7] Impedimetric Point-of-Care Cardiac Marker System
    Hamad, Eyad M.
    McAdams, Eric T.
    McLaughlin, James A.
    COMPUTING IN CARDIOLOGY 2010, VOL 37, 2010, 37 : 201 - 204
  • [8] Pocket mobile smartphone system for the point-of-care submandibular ultrasonography
    Wojtczak, Jacek
    Bonadonna, Peter
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (03): : 573 - 577
  • [9] Point-of-care, multispectral, smartphone-based dermascopes for dermal lesion screening and erythema monitoring
    Uthoff, Ross D.
    Song, Bofan
    Maarouf, Melody
    Shi, Vivian
    Liang, Rongguang
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (06)
  • [10] Smartphone chloridometer for point-of-care applications
    Zhang, Chenji
    Kim, Jimin P.
    Creer, Michael
    Yang, Jian
    Liu, Zhiwen
    ULTRAFAST NONLINEAR IMAGING AND SPECTROSCOPY V, 2017, 10380