Summary of: Attitudes of general dental practitioners to the maintenance of Locator retained implant overdentures

被引:0
|
作者
Hancocks, Stephen
机构
[1] Clinical Assistant Professor,Department of Prosthodontics
[2] University Medical Center Freiburg,Department of Periodontics
[3] School of Dentistry,undefined
[4] Visiting Research Professor,undefined
[5] University of Maryland Baltimore,undefined
[6] School of Dentistry,undefined
关键词
D O I
10.1038/sj.bdj.2014.79
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction Locator retained implant overdentures are associated with a high incidence of prosthodontic complications. This study investigated whether general dental practitioners (GDPs) were willing to maintain these prostheses in primary dental care. Method A questionnaire was distributed to all GDPs referring patients for an implant assessment to the Charles Clifford Dental Hospital, Sheffield between 1 January 2012 and 30 June 2012. Results Ninety-four out of one hundred and forty-six questionnaires were returned (response rate: 64%). Thirteen GDPs (14%) were able to identify the Locator attachment system from clinical photographs. Eighty-two GDPs (87%) would adjust the fit surface of a Locator retained implant overdenture. Twenty-three GDPs (25%) would replace a retentive insert, 18 GDPs (19%) would tighten a loose abutment, 68 GDPs (72%) would debride abutments and 25 GDPs (27%) would remake a Locator-retained implant overdenture. Forty-seven GDPs (50%)) felt that the maintenance of these prostheses was not their responsibility. The main barriers identified to maintenance by GDPs were a lack of training, knowledge and equipment. Seventy GDPs (74%) would like further training in this area. Conclusions GDPs are not familiar with the Locator attachment system and are reluctant to maintain implant retained overdentures. GDPs would like further training in this area.
引用
收藏
页码:134 / 135
页数:2
相关论文
共 50 条
  • [1] Summary of: Attitudes of general dental practitioners to the maintenance of Locator retained implant overdentures
    Sebastian B. M. Patzelt
    British Dental Journal, 2014, 216 : 134 - 135
  • [2] Attitudes of general dental practitioners to the maintenance of Locator retained implant overdentures
    Vere, J. W.
    Eliyas, S.
    Wragg, P. F.
    BRITISH DENTAL JOURNAL, 2014, 216 (03) : E5 - E5
  • [3] Attitudes of general dental practitioners to the maintenance of Locator retained implant overdentures
    J. W. Vere
    S. Eliyas
    P. F. Wragg
    British Dental Journal, 2014, 216 : E5 - E5
  • [4] Prosthodontic Maintenance Requirements of Implant-Retained Overdentures Using the Locator Attachment System
    Vere, Joe
    Hall, Derek
    Patel, Raj
    Wragg, Phillip
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2012, 25 (04) : 392 - 394
  • [5] An Alternative Impression Technique for Implant-Retained Overdentures With Locator Attachments
    Uludag, Bulent
    Cogalan, Kemal
    Polat, Serdar
    JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (06) : 451 - 453
  • [6] MAGNET RETAINED OVERDENTURES USING THE ASTRA DENTAL IMPLANT SYSTEM
    WALMSLEY, AD
    BRADY, CL
    SMITH, PL
    FRAME, JW
    BRITISH DENTAL JOURNAL, 1993, 174 (11) : 399 - 404
  • [7] Locator attachments as an alternative to ball attachments in 2-implant retained mandibular overdentures
    Geckili, Onur
    Bilhan, Hakan
    Bilgin, Tayfun
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2007, 73 (08): : 691 - 694
  • [8] Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures
    ELsyad, Moustafa Abdou
    Errabti, Hatem Mokhtar
    Mustafa, Aisha Zakaria
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (08): : 656 - 664
  • [9] Investigation of Clinical and Laboratory Wear in Locator-Supported, Implant-Retained Overdentures
    Hahnel, Sebastian
    Alamanos, Christos
    Schneider-Feyrer, Sibylle
    Stoeckle, Matthias
    Rosentritt, Martin
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (04) : 334 - 337
  • [10] Impact of crestal bone resorption on quality of life and professional maintenance with conventional dentures or Locator-retained mandibular implant overdentures
    Matthys, Carine
    Vervaeke, Stijn
    Jacquet, Wolfgang
    De Bruyn, Hugo
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (06): : 886 - 894