Simultaneous absolute and differential operation of eddy current bobbin probes for heat exchanger tube inspection

被引:0
|
作者
Sullivan, SP [1 ]
Smith, SP [1 ]
Sharp, FL [1 ]
机构
[1] Chalk River Labs, Nondestruct Testing Dev Branch, Components & Syst Div, Chalk River, ON K0J 1J0, Canada
关键词
Eddy current testing - Eddy currents;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Absolute/differential probes should be operated with current in the two bobbin coils flowing in phase with one another to optimize absolute signals. Differential probe signals are independent of the relative sense of current flowing in the coils. That is, differential signals from a probe with the current flowing in the same direction in both coils are identical to signals from a probe with the drive current in one coil 180 degrees out of phase with current in the other.
引用
收藏
页码:634 / 638
页数:5
相关论文
共 50 条
  • [1] Bobbin, Nonmultiplexed Array, and Multiplexed Array Eddy Current Probes for Heat Exchanger Inspection
    Savard, S.
    Grenier, M.
    Renaud, J.
    MATERIALS EVALUATION, 2019, 77 (03) : 401 - 410
  • [2] Code validation for eddy current modeling: Tube inspection with reflection differential probes
    Schumm, A
    Nakagawa, N
    Review of Progress in Quantitative Nondestructive Evaluation, Vols 24A and 24B, 2005, 760 : 509 - 515
  • [3] In situ eddy current inspection of heat exchanger tubes
    Trivedi, AJ
    Parikh, RR
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 1729 - 1735
  • [4] EDDY-CURRENT INSPECTION OF NONFERROUS HEAT-EXCHANGER TUBING
    不详
    INSIGHT, 1994, 36 (04) : 218 - 220
  • [5] Design of Differential Bobbin Probes for Inspection of Circumferential Cracks in Bolts
    Im, K. H.
    Woo, Y. D.
    Lee, S. G.
    Kim, H. J.
    Song, S. J.
    Ra, S. W.
    Kim, I. R.
    INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND ENERGY ENGINEERING (PEEE 2015), 2015, : 102 - 106
  • [6] Computer modeling of eddy current transmit-receive probes for tube inspection
    Sullivan, SP
    Cecco, VS
    Obrutsky, LS
    Humphrey, D
    Smith, SP
    Emde, KA
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 283 - 289
  • [7] SEMI-AUTOMATED EDDY CURRENT SYSTEM FOR HEAT EXCHANGER INSPECTION.
    SHARP, F.L.
    1982,
  • [8] Transmit receive eddy current probes for circumferential cracks in heat exchanger tubes
    Obrutsky, LS
    Cecco, VS
    Sullivan, SP
    Humphrey, D
    MATERIALS EVALUATION, 1996, 54 (01) : 93 - 98
  • [9] Simulation and design of ECT differential bobbin probes for the inspection of cracks in bolts
    Ra, S. W.
    Im, K. H.
    Lee, S. G.
    Kim, H. J.
    Song, S. J.
    Kim, S. K.
    Cho, Y. T.
    Woo, Y. D.
    Jung, J. A.
    4TH GLOBAL CONFERENCE ON MATERIALS SCIENCE AND ENGINEERING (CMSE 2015), 2015, 103
  • [10] Customized Eddy Current Probes for Pipe Inspection
    Machado, Miguel A.
    Rosado, Luis
    Pedrosa, Nuno
    Miranda, R. M.
    Piedade, Moises
    Santos, Telmo G.
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XX), 2017, 42 : 283 - 290