Inexpensive position sensitive detector block for 40 mm diameter PMT using quadrant sharing configuration

被引:0
|
作者
Uribe, J [1 ]
Aykac, M [1 ]
Baghaei, H [1 ]
Li, H [1 ]
Wang, Y [1 ]
Liu, Y [1 ]
Xing, T [1 ]
Wong, WH [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recent approval by CMS (former HCFA) for reimbursement of PET scans used in certain cases of diagnostic oncology, and the rapid grow of the PET market that this approval has generated (100% increase in year 2000) creates the need for more affordable dedicated PET scanners. The objective of the work presented here is the development of a position sensitive block with the same detector area (40mm x 40mm) and number of crystals, (M) of the block of a commercial camera using the photomultiplier quadrant sharing technique (PQS). This block is coupled to four single-anode 40 mm diameter PMTs and each PMT is sheared by four block detectors. Significant savings come from the number of PMTs required which are only 25% of what otherwise would be necessary to build a comparable commercial camera. Due to unused photocatode area left by a PQS array of square blocks in a detector module, a rectangular (extended) block was developed. This block maximizes use of the PMT sensitive area and minimizes gap size between modules. It was only necessary to develop the extended block because a symmetric square block uses same type of partitions like those controlling light distribution along the short side of the rectangular one. White-paint masks applied with accurate templates and airbrush were fine-tuned for every pair of adjacent crystals. Crystal decoding presents good separation uniformly distributed over the two-dimensional decoding map of the block. Composite energy spectrum of all 64 crystals shows a prominent photopeak (39% energy resolution) and relatively small Compton edge. It indicates that the block has a very uniform light collection for all crystals. It is expected that the image resolution using this type of block be comparable to the resolution of commercial cameras, because we clearly decode the same number and size of crystals.
引用
收藏
页码:1200 / 1202
页数:3
相关论文
共 24 条
  • [1] Inexpensive position sensitive detector block for dedicated PET cameras using 40-mm diameter PMT in quadrant sharing configuration
    Uribe, J
    Aykac, M
    Baghaei, H
    Li, HD
    Wang, Y
    Liu, YQ
    Wong, V
    Xing, T
    Ramirez, R
    Wong, WH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 367 - 372
  • [2] Elongated position sensitive block detector design using the PMT quadrant sharing configuration and asymmetric light partition
    Univ of Texas M.D. Anderson Cancer, Cent, Houston, United States
    IEEE Nucl Sci Symp Med Imaging Conf, (1204-1207):
  • [3] An elongated position sensitive block detector design using the PMT quadrant-sharing configuration and asymmetric light partition
    Wong, WH
    Yokoyama, S
    Uribe, J
    Baghaei, H
    Li, HD
    Wang, JM
    Zhang, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 542 - 545
  • [4] A simulation study on optically decoding reflecting windows for PMT quadrant sharing scintillation detector block
    Li, HD
    Wong, WH
    Kim, S
    Ramirez, R
    Xie, SP
    Wang, Y
    Xing, T
    Uribe, J
    Baghaei, H
    Zhang, YX
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3098 - 3102
  • [5] A simulation study on optically decoding reflecting windows for PMT quadrant sharing scintillation detector block
    Li, Hongdi
    Wong, Wai-Hoi
    Kim, Soonseok
    Liu, Shitao
    Ramirez, Rocio
    Xie, Shuping
    Wang, Yu
    Xing, Tao
    Uribe, Jorge
    Baghaei, Hossain
    Zhang, Yuxuan
    Liu, Jiguo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2557 - 2562
  • [6] New PMT-Quadrant-Sharing Shallow Block Detector Development for High Performance TOF PET Applications
    Ramirez, Rocio
    Zhang, Yuxuan
    Li, Hongdi
    Baghaei, Hossain
    Wong, Wai-Hoi
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3794 - 3796
  • [7] Readout Electronics Development Based on an ASIC for PET Detector using PMT-Quadrant-Sharing
    Xu, Tianpeng
    Chen, Jing
    Lu, Lingjun
    Deng, Zhi
    Ma, Tianyu
    Wang, Shi
    Liu, Yaqiang
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 906 - 908
  • [8] Development of Repeating Event Rejection Logic in the LYSO Detector Using PMT-Quadrant-Sharing Technique
    Lv, Zhenlei
    Gong, Guanghua
    Huang, Shuai
    Liu, Yaqiang
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [9] Signal characteristics of individual crystals in high resolution BGO detector designs using PMT-Quadrant sharing
    Uribe, J
    Li, HD
    Xing, T
    Liu, YQ
    Baghaei, H
    Wang, Y
    Aykac, M
    Ramirez, R
    Wong, WH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 355 - 361
  • [10] Electronics for a prototype variable field of view PET camera using the PMT-quadrant-sharing detector array
    Li, HD
    Wong, WH
    Zhang, N
    Wang, JM
    Uribe, J
    Baghaei, H
    Yokoyama, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 546 - 550