Serial assessment of left ventricular diastolic function after Fontan procedure

被引:109
|
作者
Cheung, YF
Penny, DJ
Redington, AN [1 ]
机构
[1] Great Ormond St Hosp Sick Children, London WC1N 3JH, England
[2] Univ London, Inst Child Hlth, London WC1N 3JH, England
关键词
diastolic function; Fontan procedure;
D O I
10.1136/heart.83.4.420
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To assess longitudinal changes in systemic ventricular diastolic function late after the Fontan procedure. Design and patients-Prospective study of 13 patients at 2.8 (2.0) years (early) and again at 11.4 (2.0) years (late) after the Fontan procedure by Doppler echocardiography with simultaneous EGG, phonocardiogram, and respirometer. Setting-Tertiary paediatric cardiac centre. Results-The isovolumic relaxation time (IVRT) was significantly longer, and E wave deceleration time, E and A wave velocities, and E:A velocity ratio were reduced compared to normal both early and late after the procedure. The mean (SD) z score of IVRT decreased significantly from +2.50 (1.00) to +1.24 (0.80) (p = 0.002), and the z score of the E wave deceleration time decreased from -1.69 (1.31) to -2.40 (1.47) (p = 0.03) during follow up. The A wave deceleration time also tended to decrease (early 80 (12) ms v late 73 (11) ms, p = 0.13) with increased follow up. There were no changes of the E and A wave velocities and E:A velocity ratio. The E wave velocity was inversely related to IVRT both early (r = -0.82, p = 0.001) and late (r = -0.59, p = 0.034) after the operation. The prevalence of diastolic flow during isovolumic relaxation decreased from 85% (11/13) to 38% (5/13) (p = 0.04), while thai. of mid diastolic flow increased from 23% (3/13) to 77% (10/13) (p = 0.02) between the two assessments. Conclusions-Left ventricular diastolic function remains highly abnormal late after the Fontan procedure. The longitudinal changes demonstrated on follow up ars compatible with reduction of left ventricular compliance in addition to persisting abnormalities of relaxation.
引用
收藏
页码:420 / 424
页数:5
相关论文
共 50 条
  • [1] Diastolic ventricular function immediately before and after Fontan procedure
    Koide, M
    Imai, Y
    Takanashi, Y
    Seo, K
    Terada, M
    Aoki, M
    Shin'oka, T
    Hiramatsu, T
    Ohta, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 505A - 505A
  • [2] Serial Doppler assessment of diastolic function before and after the Fontan operation
    Olivier, M
    O'Leary, PW
    Pankratz, VS
    Lohse, CM
    Walsh, BE
    Tajik, AJ
    Seward, JB
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (11) : 1136 - 1143
  • [3] SERIAL RADIONUCLIDE ANGIOGRAPHY FOR ASSESSMENT OF LEFT-VENTRICULAR FUNCTION IN PATIENTS WITH DOUBLE INLET LEFT-VENTRICLE AFTER THE MODIFIED FONTAN PROCEDURE
    BORGHI, A
    CARMINATI, M
    PITI, A
    MEDOLAGO, G
    CRUPI, G
    RUSSO, MG
    INVERNIZZI, G
    PERSPECTIVES IN PEDIATRIC CARDIOLOGY, VOL 2, PT 2: PEDIATRIC CARDIAC SURGERY, 1989, 2 : 234 - 237
  • [4] Assessment of Diastolic Function in Single-Ventricle Patients After the Fontan Procedure
    Margossian, Renee
    Sleeper, Lynn A.
    Pearson, Gail D.
    Barker, Piers C.
    Mertens, Luc
    Quartermain, Michael D.
    Su, Jason T.
    Shirali, Girish
    Chen, Shan
    Colan, Steven D.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2016, 29 (11) : 1066 - 1073
  • [5] Interstudy reproducibility of echocardiographic parameters in the serial assessment of left ventricular diastolic function
    Ul Haq, M. Asrar
    Mutha, V.
    Stewart, S.
    Carrington, M.
    Wong, C.
    EUROPEAN HEART JOURNAL, 2013, 34 : 194 - 194
  • [6] DIASTOLIC VENTRICULAR-FUNCTION AFTER THE FONTAN OPERATION
    PENNY, DJ
    REDINGTON, AN
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (09): : 974 - 975
  • [7] DIASTOLIC VENTRICULAR-FUNCTION AFTER THE FONTAN OPERATION - REPLY
    FROMMELT, PC
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (09): : 975 - 975
  • [8] Clinical assessment of left ventricular diastolic function
    Gibson, DG
    Francis, DP
    HEART, 2003, 89 (02) : 231 - 238
  • [9] Echocardiographic assessment of left ventricular diastolic function
    Pirat, Bahar
    Zoghbi, William A.
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2007, 7 (03): : 310 - 315
  • [10] Echocardiographic assessment of left ventricular diastolic function
    Nagueh, S. F.
    Advances in Heart Disease, 2006, : 157 - 160