New fixed-point mini-cell to investigate thermocouple drift in a high-temperature environment under neutron irradiation

被引:0
|
作者
Laurie, M. [1 ]
Sadli, M. [2 ]
Failleau, G. [2 ]
Vlahovic, L. [1 ]
Fuetterer, M. [3 ]
Lapetite, J-M. [3 ]
Fourrez, S. [4 ]
Rondinella, V. V. [1 ]
机构
[1] European Commiss, Joint Res Ctr, Inst Transuranium Elements, POB 2340, D-76125 Karlsruhe, Germany
[2] LNE Cnam, Lab Commun Metrol, St Denis, France
[3] European Commiss, Joint Res Ctr, Inst Energy & Transport, NL-1755 ZG Petten, Netherlands
[4] Thermocoax, F-61100 St Georges Des Groseille, France
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Temperature measurements in the nuclear field require a high degree of reliability and accuracy. Despite their sheathed form, thermocouples subjected to nuclear radiations undergo changes due to radiation damage and transmutation that lead to significant EMF drift during long-term fuel irradiation experiment. For the purpose of a High Temperature Reactor fuel irradiation to take place in the High Flux Reactor Petten, a dedicated fixed-point cell was jointly developed by LNE-Cnam and JRC-IET. The developed cell to be housed in the irradiation rig was tailor made to quantify the thermocouple drift during the irradiation (about two year duration) and withstand high temperature (in the range 950 degrees C - 1100 degrees C) in the presence of contaminated helium in a graphite environment. Considering the different levels of temperature achieved in the irradiation facility and the large palette of thermocouple types aimed at surveying the HTR fuel pebble during the qualification test both copper (1084.62 degrees C) and gold (1064.18 degrees C) fixed-point materials were considered. The aim of this paper is to first describe the fixed-point mini cell designed to be embedded in the reactor rig and to discuss the preliminary results achieved during some out of pile tests as much as some robustness tests representative of the reactor scram scenarios.
引用
收藏
页数:7
相关论文
共 42 条
  • [1] High-Temperature Fixed-Point Facilities for Improved Thermocouple Calibration—Euromet Project 857
    R. Morice
    F. Edler
    J. Pearce
    G. Machin
    J. Fischer
    J. R. Filtz
    International Journal of Thermophysics, 2008, 29 : 231 - 240
  • [2] High-temperature fixed-point facilities for improved thermocouple calibration-Euromet Project 857
    Morice, R.
    Edler, F.
    Pearce, J.
    Machin, G.
    Fischer, J.
    Filtz, J. R.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (01) : 231 - 240
  • [3] Construction of High-Temperature Fixed-Point Cells for Thermodynamic Temperature Assignment
    Yamada, Y.
    Anhalt, K.
    Battuello, M.
    Bloembergen, P.
    Khlevnoy, B.
    Machin, G.
    Matveyev, M.
    Sadli, M.
    Wang, T.
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 335 - 339
  • [4] Multi-Mini-Eutectic Fixed-Point Cell for Type C Thermocouple Self-Calibration
    Ongrai, O.
    Pearce, J. V.
    Machin, G.
    Norranim, U.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (2-3) : 423 - 432
  • [5] Temperature assignment of a Co-C eutectic fixed-point cell for thermocouple calibration
    Zheng, Wei
    Lu, Xiaofeng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (03)
  • [6] Multi-Mini-Eutectic Fixed-Point Cell for Type C Thermocouple Self-Calibration
    O. Ongrai
    J. V. Pearce
    G. Machin
    U. Norranim
    International Journal of Thermophysics, 2015, 36 : 423 - 432
  • [7] Evaluation and Selection of High-Temperature Fixed-Point Cells for Thermodynamic Temperature Assignment
    Yamada, Y.
    Anhalt, K.
    Battuello, M.
    Bloembergen, P.
    Khlevnoy, B.
    Machin, G.
    Matveyev, M.
    Sadli, M.
    Todd, A.
    Wang, T.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (08) : 1834 - 1847
  • [8] Evaluation and Selection of High-Temperature Fixed-Point Cells for Thermodynamic Temperature Assignment
    Y. Yamada
    K. Anhalt
    M. Battuello
    P. Bloembergen
    B. Khlevnoy
    G. Machin
    M. Matveyev
    M. Sadli
    A. Todd
    T. Wang
    International Journal of Thermophysics, 2015, 36 : 1834 - 1847
  • [9] Reliability of High-Temperature Fixed-Point Installations over 8 Years
    Elliott, C. J.
    Ford, T.
    Ongrai, O.
    Pearce, J. V.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2017, 38 (12)
  • [10] Reliability of High-Temperature Fixed-Point Installations over 8 Years
    C. J. Elliott
    T. Ford
    O. Ongrai
    J. V. Pearce
    International Journal of Thermophysics, 2017, 38