MR Angiographic Follow-Up of Intracranial Aneurysms Treated with Detachable Coils: Evaluation of a Blood-Pool Contrast Medium

被引:14
|
作者
Kau, T. [1 ]
Gasser, J. [1 ]
Celedin, S. [1 ]
Rabitsch, E. [1 ]
Eicher, W. [1 ]
Uhl, E. [2 ]
Hausegger, K. A. [1 ]
机构
[1] Gen Hosp Klagenfurt, Inst Diagnost & Intervent Radiol, A-9020 Klagenfurt, Austria
[2] Gen Hosp Klagenfurt, Dept Neurosurg, A-9020 Klagenfurt, Austria
关键词
TIME-OF-FLIGHT; MAGNETIC-RESONANCE ANGIOGRAPHY; DIGITAL-SUBTRACTION-ANGIOGRAPHY; AORTOILIAC OCCLUSIVE DISEASE; CEREBRAL ANEURYSMS; ENDOVASCULAR TREATMENT; PHASE-III; 1.5; TESLA; MS-325; MULTICENTER;
D O I
10.3174/ajnr.A1622
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Blood-pool agents are promising in the imaging of small vessels with slow or complex flow. Our aim was to compare blood-pool contrast-enhanced MR angiography (BPCE-MRA) using gadofosveset trisodium (Vasovist) with 3D time-of-flight MRA (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular therapy. MATERIALS AND METHODS: We included 32 patients with a total of 37 coiled aneurysms. MRAs in the early steady-state phase were performed on a 1.5T scanner within 8 days of digital subtraction angiography QSA). Two radiologists independently analyzed TOF-MRA and BPCE-MRA images. Consensus was reached by review involving a third neuroradiologist. DSA images were interpreted separately by an interventional radiologist. Findings were assigned to 1 of 3 categories: 1) complete occlusion, 2) residual neck, and 3) residual aneurysm. RESULTS: Follow-up DSA demonstrated 13 complete obliterations (class 1), 13 residual necks (class 2), and 11 residual aneurysms (class 3). Weighted K statistics showed substantial concordance of TOF-MRA and DSA (0.664) as well as BPCE-MRA and DSA (0.724) ratings. Comparison between TOF-MRA and BPCE-MRA found excellent agreement (0.818) with only 6 (16.2%) discrepancies. For detecting residual flow, the difference in accuracy of both MRA techniques (83.8% versus 91.9%) was not significant (McNemar, P = 1.000). BPCE-MRA showed a tendency towards higher sensitivity and specificity (91.7% and 92.3%, respectively) compared with TOF-MRA (87.5% and 76.9%). CONCLUSIONS: In classifying the completeness of endovascular cerebral aneurysm therapy, we found that BPCE-MRA and 3D TOF-MRA showed very good agreement. The use of Vasovist did not lead to a significantly increased accuracy of MRA follow-up.
引用
收藏
页码:1524 / 1530
页数:7
相关论文
共 50 条
  • [1] Intracranial aneurysms treated with Guglielmi detachable coils - Imaging follow-up with contrast-enhanced MR Angiography
    Gauvrit, JY
    Leclerc, X
    Caron, S
    Taschner, CA
    Lejeune, JP
    Pruvo, JP
    STROKE, 2006, 37 (04) : 1033 - 1037
  • [2] Angiographic follow-up of vertebrobasilar artery aneurysms treated with detachable coils
    C. Groden
    B. Eckert
    T. Ries
    E. Neumaier Probst
    T. Kucinski
    H. Zeumer
    Neuroradiology, 2003, 45 : 435 - 440
  • [3] Angiographic follow-up of vertebrobasilar artery aneurysms treated with detachable coils
    Groden, C
    Eckert, B
    Ries, T
    Probst, EN
    Kucinski, T
    Zeumer, H
    NEURORADIOLOGY, 2003, 45 (07) : 435 - 440
  • [4] Follow-up of intracranial aneurysms selectively treated with coils: Prospective evaluation of contrast-enhanced MR angiography
    Pierot, L
    Delcourt, C
    Bouquigny, F
    Breidt, D
    Feuillet, B
    Lanoix, O
    Gallas, S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (04) : 744 - 749
  • [5] Prospective evaluation of time-of-flight MR angiography in the follow-up of intracranial saccular aneurysms treated with Guglielmi detachable coils
    Brunereau, L
    Cottier, JP
    Sonier, CB
    Medioni, B
    Bertrand, P
    Rouleau, P
    Sirinelli, D
    Herbreteau, D
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (02) : 216 - 223
  • [6] Follow-up angiography of intracranial aneurysms treated with endovascular placement of Guglielmi detachable coils
    Thornton, J
    Debrun, GM
    Aletich, VA
    Bashir, Q
    Charbel, FT
    Ausman, J
    NEUROSURGERY, 2002, 50 (02) : 239 - 249
  • [7] Intracranial aneurysms treated with Guglielmi detachable coils: Usefulness of 6-month imaging follow-up with contrast-enhanced MR angiography
    Gauvrit, JY
    Leclerc, X
    Pernodet, M
    Lubicz, B
    Lejeune, JP
    Leys, D
    Pruvo, JP
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (03) : 515 - 521
  • [8] Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils
    Cognard, C
    Weill, A
    Spelle, L
    Piotin, M
    Castaings, L
    Rey, A
    Moret, J
    RADIOLOGY, 1999, 212 (02) : 348 - 356
  • [9] MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis
    Kwee, Thomas C.
    Kwee, Robert M.
    NEURORADIOLOGY, 2007, 49 (09) : 703 - 713
  • [10] MR angiography in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils: systematic review and meta-analysis
    Thomas C. Kwee
    Robert M. Kwee
    Neuroradiology, 2007, 49 : 703 - 713