Measurement of spectacle-induced aniseikonia in axial anisometropia using the New Aniseikonia Test

被引:1
|
作者
Rajab, Ghada Z. El-Abedin [1 ]
Elaziz, Mohamed S. A. [1 ]
Soliman, Shiamaa S. [2 ]
Basiony, Ahmed, I [1 ]
机构
[1] Menoufia Univ Hosp, Dept Ophthalmol, 10 Gamal Abo El Ghar Stt Off Sabry Abo Alam St, Menoufia 32111, Egypt
[2] Menoufia Univ Hosp, Dept Publ Hlth & Community Med, Menoufia, Egypt
关键词
amblyopia; aniseikonia; anisometropia; Knapp's rule; suppression;
D O I
10.4103/ejos.ejos_56_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To determine whether spectacle correction in axial anisometropes can cause significant aniseikonia. Patients and methods A cross-sectional study was conducted on eight patients who had axial anisometropia with a spherical equivalent difference between both eyes equal or more than 4 D. Aniseikonia was measured using the New Aniseikonia Test 'Awaya.' Aniseikonia of 3% or more was considered clinically significant. Spearman correlation between the amount of aniseikonia and anisometropia was calculated. Results The mean +/- SD age of the patients was 13 +/- 4.64 years (range, 7-24 years). Anisometropia ranging from -14.5 to +5.25 DS with a mean +/- SD of -6.70 +/- 5.18. The overall mean +/- SD of aniseikonia was -1.45 +/- 0.52. Five patients had no aniseikonia, three patients had -1% aniseikonia, and three patients had -2% aniseikonia. Spearman correlation showed an insignificant positive correlation between the amount of anisometropia and aniseikonia (r=0.05, P=0.86). Conclusion Among our cases, spectacle correction in axial anisometropia did not lead to significant aniseikonia using the New Aniseikonia Test. Aniseikonia should be assessed in patients with anisometropia as 1% of aniseikonia per diopter of anisometropia does not apply in every case.
引用
收藏
页码:180 / 186
页数:7
相关论文
共 50 条
  • [1] ON THE RELATION BETWEEN ANISEIKONIA AND AXIAL ANISOMETROPIA
    RABIN, J
    BRADLEY, A
    FREEMAN, RD
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1983, 60 (07): : 553 - 558
  • [2] THE NEW ANISEIKONIA TEST UNDERESTIMATES ANISEIKONIA
    STONE, P
    MCCORMACK, G
    PELI, E
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1284 - 1284
  • [3] REDUCED ANISEIKONIA IN AXIAL ANISOMETROPIA WITH CONTACT-LENS CORRECTION
    WINN, B
    ACKERLEY, RG
    BROWN, CA
    MURRAY, FK
    PRAIS, J
    STJOHN, MF
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1988, 8 (03) : 341 - 344
  • [4] Aniseikonia and visual functions with optical correction and after refractive surgery in axial anisometropia
    Hassan Ali Abdelzaher
    Mohamed Karim Sidky
    Ahmed Awadein
    Mohamed Hosny
    International Ophthalmology, 2022, 42 : 1669 - 1677
  • [5] Aniseikonia and visual functions with optical correction and after refractive surgery in axial anisometropia
    Abdelzaher, Hassan Ali
    Sidky, Mohamed Karim
    Awadein, Ahmed
    Hosny, Mohamed
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (06) : 1669 - 1677
  • [6] The validity and repeatability of the new Aniseikonia Test
    Antona, Beatriz
    Barra, Francisco
    Barrio, Ana
    Gonzalez, Enrique
    Sanchez, Isabel
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (12) : 903 - 909
  • [7] NEW VECTOGRAPHIC NEAR TEST FOR ANISEIKONIA
    GROLMAN, B
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1972, 49 (11): : 977 - &
  • [8] Validity and repeatability of a new test for aniseikonia
    Antona, Beatriz
    Barra, Francisco
    Barrio, Ana
    Gonzalez, Enrique
    Sanchez, Isabel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) : 58 - 62
  • [9] Evaluation of Aniseikonia in Patients with Successfully Treated Anisometropic Amblyopia Using Spatial Aniseikonia Test
    Takigawa, Ryusei
    Sasaki, Kakeru
    Hirota, Masakazu
    Nakagawa, Maki
    Sasaki, Kozue
    Mihashi, Toshifumi
    Mizuno, Yoshinobu
    Mizota, Atsushi
    Matsuoka, Kumiko
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (11)