Arteriovenous Fistula Survival with Buttonhole (Constant Site) Cannulation for Hemodialysis Access

被引:18
|
作者
Kandil, Hala [1 ]
Collier, Sophie [1 ]
Yewetu, Enat [1 ]
Cross, Jennifer [2 ]
Davenport, Andrew [2 ]
机构
[1] Royal Free Hosp, Dept Microbiol, London NW3 2PF, England
[2] Royal Free Hosp, UCL Ctr Nephrol, London NW3 2PF, England
关键词
hemodialysis; arteriovenous fistula; cannulation; buttonhole; bacteremia; STAPHYLOCOCCUS-AUREUS BACTEREMIA; ROPE-LADDER; NEEDLE INSERTION; VASCULAR ACCESS; OUTCOMES; TRIAL; COMPLICATIONS; DIALYSIS; HEPARIN; CREATE;
D O I
10.1097/MAT.0000000000000018
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Buttonhole needling for arteriovenous fistulae (AVF) has increased in popularity among dialysis centers. Concerns have been raised about the risks of infection, so we reviewed our experience of buttonhole needling in 227 adult patients on hemodialysis. The mean buttonhole AVF survival was 27.0 months, in 227 patients, 61.1% male, mean age 63.8 +/- 15.5 years, 45.8% with diabetes mellitus, median dialysis vintage 19 months (6.5-42.8). Ninety-six patients transferred to rope ladder AVF cannulation, because of cannulation failure in 25%, persistent bleeding at the needling site in 24%, fistula thrombosis in 14%, and infections in 15%. Because of persistent methicillin-sensitive Staphylococcus aureus (MSSA) or methicillin-resistant S. aureus (MRSA) colonization, 18.8% discontinued buttonhole needling. Transfer from buttonhole needling was more common for people with diabetes (X-2 = 6.57; p = 0.035), older patients (odds ratio, 0.985; p = 0.007), and persistent MSSA/MRSA colonization (odds ratio, 0.88; p = 0.037). Eleven episodes of suspected buttonhole S. aureus bacteremia occurred giving a bacteremia rate of 2.94 per 100 patient years, and 15 local infections giving an infection rate of 4.01 per 100 patient years. In this large series of buttonhole AVF access, although infection rates were increased, more patients discontinued buttonhole needling because of technical cannulation problems and persistent bleeding from needle tracks.
引用
收藏
页码:95 / 98
页数:4
相关论文
共 50 条
  • [1] Subscapular abscess associated with buttonhole cannulation technique of arteriovenous fistula for hemodialysis access
    Koratala, Abhilash
    Alquadan, Kawther F.
    Chornyy, Volodymyr
    Qadri, Irfan
    Ejaz, Abutaleb Ahsan
    JOURNAL OF VASCULAR ACCESS, 2017, 18 (02): : E18 - E19
  • [2] Arteriovenous Buttonhole Access Cannulation in Pediatric Patients on Hemodialysis
    Moore, Tyson
    Brightman, Stephanie
    Dodson, David L.
    Warady, Bradley A.
    NEPHROLOGY NURSING JOURNAL, 2019, 46 (04) : 407 - 411
  • [3] The buttonhole technique for arteriovenous fistula cannulation
    Ball, Lynda K.
    NEPHROLOGY NURSING JOURNAL, 2006, 33 (03) : 299 - 304
  • [4] Hemodialysis patients' experience with and attitudes toward the buttonhole technique for arteriovenous fistula cannulation
    Hashmi, A.
    Cheema, M. Q.
    Moss, A. H.
    CLINICAL NEPHROLOGY, 2010, 74 (05) : 346 - 350
  • [5] Good outcomes for arteriovenous fistula with buttonhole cannulation for chronic hemodialysis in children and adolescents
    Garza, Brittany
    Geer, Jessica
    Swartz, Sarah J.
    Srivaths, Poyyapakkam
    Huynh, Tam T. T.
    Brewer, Eileen D.
    PEDIATRIC NEPHROLOGY, 2023, 38 (02) : 509 - 517
  • [6] Good outcomes for arteriovenous fistula with buttonhole cannulation for chronic hemodialysis in children and adolescents
    Brittany Garza
    Jessica Geer
    Sarah J. Swartz
    Poyyapakkam Srivaths
    Tam T. T. Huynh
    Eileen D. Brewer
    Pediatric Nephrology, 2023, 38 : 509 - 517
  • [7] Efficacy of buttonhole cannulation (BH) in hemodialysis patients with arteriovenous fistula: a meta-analysis
    Ren, Chong
    Han, Xin
    Huang, Bihong
    Yuan, Li
    Cao, Yanpei
    Yang, Xiaoli
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (08): : 15363 - 15370
  • [8] Patients' Perspectives of Constant-Site (Buttonhole) Cannulation for Haemodialysis Access
    Ward, Janice
    Shaw, Kate
    Davenport, Andrew
    NEPHRON CLINICAL PRACTICE, 2010, 116 (02): : C123 - C127
  • [9] Utility of the buttonhole cannulation method for hemodialysis patients with arteriovenous fistulas
    Zbylut J Twardowski
    Nature Clinical Practice Nephrology, 2007, 3 : 648 - 649
  • [10] Utility of the buttonhole cannulation method for hemodialysis patients with arteriovenous fistulas
    Twardowski, Zbylut J.
    NATURE CLINICAL PRACTICE NEPHROLOGY, 2007, 3 (12): : 648 - 649