Voltammetric determination of phenmedipham herbicide using a multiwalled carbon nanotube paste electrode

被引:3
|
作者
Demir, Ersin [1 ]
Inam, Recai [2 ]
机构
[1] Istanbul Okan Univ, Fac Engn, Dept Food Engn, Istanbul, Turkey
[2] Gazi Univ, Fac Sci, Dept Chem, Ankara, Turkey
关键词
Square-wave voltammetry; phenmedipham herbicide; carbon paste electrodes; determination; PERFORMANCE LIQUID-CHROMATOGRAPHY; ADSORPTIVE STRIPPING VOLTAMMETRY; DOPED DIAMOND ELECTRODE; N-METHYLCARBAMATE PESTICIDES; CHEMILUMINESCENCE DETECTION; FLUORESCENCE DETECTION; CARBAMATE PESTICIDES; WATER SAMPLES; ELECTROANALYTICAL DETERMINATION; MASS-SPECTROMETRY;
D O I
10.3906/kim-1709-41
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Phenmedipham is an herbicide used especially in the sugar beet harvest to fight against broad-leaved weeds and studies of its voltammetric behavior and detection have not been done before. The superior properties of carbon nanotubes such as electrical conductivity, mechanical strength, and wide potential ranges make them attractive for chemical sensors and the phenmedipham compound gave an oxidation peak at +1320 mV (vs. Ag/AgCl) on the nanostructured multiwalled carbon nanotube paste electrode. Square wave voltammetric measurements recorded for phenmedipham showed that the peak current increased linearly between 0.02 and 2.0 mg/L with a regression coefficient of r = 0.9989, and the limit of detection and limit of quantification were calculated as 6.96 mu g/L and 23.2 mu g/L, respectively. The applicability and the selectivity of the improved square wave voltammetric method for the phenmedipham assay were investigated in the presence of certain herbicides and fungicides such as carbendazim, benomyl, aclonifen, ethofumesate, metamitron, and p-acetamsidide (methacetin) Phenmedipham at 1 mg/L with the same amount of these pesticides was determined to have recoveries of 103.5 +/- 0.07, 94.5 +/- 2.8, 104.3 +/- 1.8, 101.9 +/- 3.1, 93.8 +/- 1.7, and 101.3 +/- 1.8, respectively (n = 3). The method was also applied to the phenmedipham assay in saturated tea sugar prepared as a spiked natural sample and 1.0 g/L phenmedipham in the sugar solution was successfully determined with a relative error of -5.0% and a relative standard deviation of 3.16%.
引用
收藏
页码:997 / 1007
页数:11
相关论文
共 50 条
  • [1] Voltammetric determination of ibuprofen using a carbon paste - multiwalled carbon nanotube composite electrode
    Irisais Rivera-Hernandez, Selene
    Arturo Alvarez-Romero, Giaan
    Corona-Avendano, Silvia
    Elena Paez-Hernandez, Maria
    Andres Galan-Vidal, Carlos
    Romero-Romo, Mario
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2016, 44 (05) : 483 - 494
  • [2] Multiwalled carbon nanotube/ionic liquid paste electrode for voltammetric determination of sulfachlorpyridazine
    Aleixo, Herbert
    Okumura, Leonardo Luiz
    Gurgel, Alexandre
    Souza Silva, Astrea Filomena
    Diniz, Juliana Aparecida
    ANALYTICAL METHODS, 2019, 11 (13) : 1743 - 1750
  • [3] Voltammetric Determination of Nimesulide Using Multiwalled Carbon Nanotubes Modified Carbon Paste Electrode
    Agin, Fatma
    Serdaroglu, Vildan
    TURKISH JOURNAL OF PHARMACEUTICAL SCIENCES, 2016, 13 (03) : 335 - 341
  • [4] Glycine functionalized multiwalled carbon nanotube modified carbon paste electrode for the selective determination of Norepinephrine: A Voltammetric study
    Anagawadi, Rohini B.
    Mahanthesha, K. R.
    RESULTS IN CHEMISTRY, 2024, 7
  • [5] Voltammetric determination of nitrite by using a multiwalled carbon nanotube paste electrode modified with chitosan-functionalized silver nanoparticles
    Bibi, Sania
    Zaman, Muhammad Iqbal
    Niaz, Abdul
    Rahim, Abdur
    Nawaz, Mohsan
    Arian, Muhammad Bilal
    MICROCHIMICA ACTA, 2019, 186 (09)
  • [6] Voltammetric determination of nitrite by using a multiwalled carbon nanotube paste electrode modified with chitosan-functionalized silver nanoparticles
    Sania Bibi
    Muhammad Iqbal Zaman
    Abdul Niaz
    Abdur Rahim
    Mohsan Nawaz
    Muhammad Bilal Arian
    Microchimica Acta, 2019, 186
  • [7] Multiwalled carbon nanotube paste electrode as an easy, inexpensive and highly selective sensor for voltammetric determination of Risperidone
    Afkhami, Abbas
    Ghaedi, Hamed
    ANALYTICAL METHODS, 2012, 4 (05) : 1415 - 1420
  • [8] Voltammetric Determination of Carbidopa Using a modified Multiwall Carbon Nanotube Paste Electrode
    Mohadesi, Alireza
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 2430 - 2439
  • [10] Voltammetric determination of disinfectants at multiwalled carbon nanotube modified glassy carbon electrode
    I. Baranowska
    K. Bijak
    Journal of Analytical Chemistry, 2013, 68 : 891 - 895