Comparison of the thereto-hydraulic performance and the entropy generation rate for two types of low temperature solar collectors using CFD

被引:20
|
作者
Ramirez-Minguela, J. J. [1 ]
Alfaro-Ayala, J. A. [1 ]
Rangel-Hernandez, V. H. [2 ]
Uribe-Ramirez, A. R. [1 ]
Mendoza-Miranda, J. M. [3 ]
Perez-Garcia, V [2 ]
Belman-Flores, J. M. [2 ]
机构
[1] Univ Guanajuato, Dept Chem Engn, DCNE, Col Norio Alta S-N, Guanajuato 36050, Gto, Mexico
[2] Univ Guanajuato, Dept Mech Engn, DICIS, Salamanca Valle Santiago Km 3-5 1-8, Salamanca 36885, Gto, Mexico
[3] Inst Politecn Nacl, Unidad Profes Interdisciplinaria Ingn, Campus Guanajuato,Av Mineral Valenciana 200 Fracc, Silao De La Victoria 36275, Gto, Mexico
关键词
Solar collector; Thermal performance; Entropy generation analysis; CFD; FLAT-PLATE COLLECTOR; WATER-HEATING SYSTEMS; THERMAL PERFORMANCE; LOSS COEFFICIENT; HEATERS; FLOW; ENERGY; MODEL; FIELD; ENHANCEMENT;
D O I
10.1016/j.solener.2018.03.050
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this work, a comparison of the thermo-hydraulic performance and the entropy generation rate for two different types of low temperature solar collectors: flat plate solar collector (FPC) and water-in-glass evacuated tube solar collector (ETC), is addressed. The absorber area for both solar collectors were considered to be equal for a reliable comparison. The operation of the solar collectors was simulated under different volumetric flow rates and solar radiation values for the state of Guanajuato in Mexico. The volumetric flow rate for both collectors ranged from 1 to 9 L/min. The variation of the solar radiation was based on: (1) the solar radiation taken from several experimental tests reported elsewhere, (2) the month with the lowest average solar radiation in one year, (3) the average solar radiation of one year and (4) the month with the highest average solar radiation in one year. The buoyancy effects were considered in the CFD simulations using the Boussinesq approximation (BA) model. The distribution profiles of temperature, pressure, and velocity inside the tubes of the solar collectors, along with the local entropy generation rate distribution due to heat transfer and the fluid viscosity, are shown in detail. The results show a better thermal performance for the solar water-in-glass evacuated tube collector (ETC) than for the flat plate solar collector (FPC) at low flow rates (under 3.0 L/min). The outlet temperature reached is similar in both collectors for volumetric flow rates higher than 3.0 L/min. The analysis of the entropy generation rate shows that the generation due to the transfer of heat is higher for the ETC than for the FPC, and this contribution is up to 10% of the total entropy generation rate; on the other hand, the generation rate due to the fluid viscosity is higher for the FPC than the ETC at high volumetric flow rates (above 3.5 L/min), however, this contribution is negligible. Finally, the total entropy generation rate is higher for the FPC than the ETC at low volumetric flow rates (below 3.0 L/min) and this is increased if the solar radiation increases.
引用
收藏
页码:123 / 137
页数:15
相关论文
共 11 条
  • [1] Performance Comparison of Different Flat Plate Solar Collectors by Means of the Entropy Generation Rate Using Computational Fluid Dynamics
    Ramirez-Minguela, J. J.
    Rangel-Hernandez, V. H.
    Alfaro-Ayala, J. A.
    Elizalde-Blancas, F.
    Ruiz-Camacho, B.
    Lopez-Nunez, O. A.
    Alvarado-Rodriguez, C. E.
    ENTROPY, 2023, 25 (04)
  • [2] Performance comparison of solar stills using two kinds of solar collectors
    Bakes, Gulan A.
    Algburi, Sameer
    Ahmed, Omer K.
    Ahmed, Ahmed H.
    DESALINATION AND WATER TREATMENT, 2023, 313 : 1 - 11
  • [3] Comparison of the effect of using helical strips and fines on the efficiency and thermal-hydraulic performance of parabolic solar collectors
    Aghaei, Alireza
    Enayati, Mojtaba
    Beigi, Negin
    Ahmadi, Amir
    Pourmohamadian, Hossein
    Sadeghi, Shayan
    Dezfulizadeh, Amin
    Golzar, Ali
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [4] Impact of fin and hybrid nanofluid on hydraulic-thermal performance and entropy generation in a solar collector using a two-phase approach
    Abidi, Awatef
    Sajadi, S. Mohammad
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2023, 156 : 311 - 320
  • [5] Investigation of thermal performance and entropy generation rate of evacuated tube collector solar air heater with inserted baffles and metal foam: A CFD approach
    Abrofarakh, Moslem
    Moghadam, Hamid
    RENEWABLE ENERGY, 2024, 223
  • [6] Enhancing thermal performance and reducing entropy generation rate in evacuated tube solar air heaters with inserted baffle plate using static mixers: A CFD-RSM analysis
    Abrofarakh, Moslem
    Moghadam, Hamid
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 55
  • [7] A numerical study on the performance of a superhydrophobic coated very low head (VLH) axial hydraulic turbine using entropy generation method
    Haghighi, Mohammad Hadi Sotoude
    Mirghavami, Seyed Mohammad
    Ghorani, Mohammad Mandi
    Riasi, Alireza
    Chini, Seyed Farshid
    RENEWABLE ENERGY, 2020, 147 : 409 - 422
  • [8] Performance Analysis of the Low-Temperature Solar-Boosted Power Generation System-Part I: Comparison Between Kalina Solar System and Rankine Solar System
    Sun, Faming
    Ikegami, Yasuyuki
    Arima, Hirofumi
    Zhou, Weisheng
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (01):
  • [9] Numerical analysis of the thermo-hydraulic performance and entropy generation rate of a water-in-glass evacuated tube solar collector using TiO2 water-based nanofluid and only water as working fluids
    Lopez-Nunez, Oscar A.
    Alfaro-Ayala, J. Arturo
    Ramirez-Minguela, J. J.
    Banda, Fernando Cano-
    Ruiz-Camacho, B.
    Belman-Flores, Juan Manuel
    RENEWABLE ENERGY, 2022, 197 : 953 - 965
  • [10] Investigation into the effect of twisted tape on the thermo-hydraulic performance and entropy generation of turbulent flow of mono and hybrid magnetic nanofluids inside a parabolic solar collector absorber tube by applying two-phase analysis
    Tahmasebi, Ahmad
    Abed, Azher M.
    Aghaei, Alireza
    Izadi, Farhad
    Malekshah, Emad Hasani
    Aybar, Hikmet S.
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2023, 150 : 318 - 328