Experimental studies and numerical simulation of evaporative cooling of air with a water spray .2. Horizontal counter flow

被引:45
|
作者
Kachhwaha, SS [1 ]
Dhar, PL [1 ]
Kale, SR [1 ]
机构
[1] INDIAN INST TECHNOL,DEPT MECH ENGN,NEW DELHI 110016,INDIA
关键词
D O I
10.1016/S0017-9310(97)00131-2
中图分类号
O414.1 [热力学];
学科分类号
摘要
Hollow cone water sprays are used in many humidifying, cooling and scrubbing applications. In a companion paper by Kachhwaha et al. Experimental studies and numerical simulation of evaporative cooling of air with a water spray: part I-horizontal parallel flow; International Journal of Heat and Mass Transfer, 1996a (submitted), a detailed study of hollow cone water sprays in horizontal parallel flow has been given. In this paper the studies have been extended to a horizontal counterflow configuration where reversal of the direction of motion of some drops is considered. These set of equations are space marched numerically and the solution is obtained in an iterative manner. The water spray nozzle was located at the wind tunnel exit face, facing upstream, for obtaining experimental data for this configuration. Model predictions of air condition change agree well with experimental data. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:465 / 474
页数:10
相关论文
共 50 条
  • [1] Experimental studies and numerical simulation of evaporative cooling of air with a water spray .1. Horizontal parallel flow
    Kachihwaha, SS
    Dhar, PL
    Kale, SR
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (02) : 447 - 464
  • [3] Numerical simulation and optimization of spray evaporative cooling in air duct
    Xiao, Yimin
    Tao, Yao
    Gao, Yanghua
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2015, 47 (04): : 76 - 80
  • [4] Numerical simulation and experimental study of air treatment process with water spray of one row counter flow
    Ni, Bo
    2001, Editorial Board of Journal of Dong Hua University (18):
  • [6] Evaporative cooling by water spray systems: CFD simulation, experimental validation and sensitivity analysis
    Montazeri, H.
    Blocken, B.
    Hensen, J. L. M.
    BUILDING AND ENVIRONMENT, 2015, 83 : 129 - 141
  • [7] Experimental Study and Numerical Simulation on Evaporative Cooling of Fine Water Mist in Outdoor Environment
    Wang Jun-feng
    Tu Xin-cheng
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 1, PROCEEDINGS, 2009, : 156 - 159
  • [8] Numerical simulation of counter-flow spray saturator for humid air turbine cycle
    Wang, Yuzhang
    Li, Yixing
    Weng, Shilie
    Wang, Yonghong
    ENERGY, 2007, 32 (05) : 852 - 860
  • [9] Membrane evaporative cooling to 30°C or less 2.: Membrane evaporative air cooling
    Loeb, S
    ADVANCED MEMBRANE TECHNOLOGY, 2003, 984 : 528 - 537
  • [10] Experimental investigation and CFD simulation of horizontal air/water slug flow
    Vallee, Christophe
    Hoehne, Thomas
    Prasser, Horst-Michael
    Seuhnel, Tobias
    KERNTECHNIK, 2006, 71 (03) : 95 - 103