The position index of a glare source at the borderline between comfort and discomfort (BCD) in the whole visual field

被引:30
|
作者
Kim, Wonwoo [1 ]
Han, Hyunjoo [1 ]
Kim, Jeong Tai [1 ]
机构
[1] Kyung Hee Univ, Dept Architectural Engn, Gyeonggi Do 446701, Yongin, South Korea
关键词
Position index; Sensation of brightness; Luminance; Glare;
D O I
10.1016/j.buildenv.2008.07.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The objective of this study was to propose a new position index for a source located in the whole visual field, including the lower visual field. The sensation of brightness was tested at various positions in the visual field. The Glare Tester especially designed for and used in this experiment had two sources: the standard source located on the line of sight and the test source located at a designated position in the visual field. The boundary of the visual field, BCD luminance on the line of sight, and BCD luminance at various positions in the visual field were measured. The visual field was measured, and the boundaries were approximately 90 degrees temporally, 67 degrees, inferiorly, and 50 degrees, superiorly. From the measurement of BCD luminance on the line of sight, the BCD luminance was obtained at 2590 cd/m(2) under the conditions of a source size of 0.0011 sr and background luminance of 34.3 cd/m(2). In measuring BCD luminance at various positions, the standard source was set to the BCD luminance of each observer, with the luminance of the test source being increased. The observers were asked to stop when the sensation of the test source became equal to that of the standard source. From the results of these measurements, the position index Pi was derived. Finally, a chart for determining the position index Pi was proposed based on the three measurements. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1017 / 1023
页数:7
相关论文
共 34 条
  • [1] Extension of the position index of discomfort glare to the whole visual field
    Kanazawa Institute of Technology, Kanazawa, Japan
    不详
    不详
    Shomei Gakkai Shi, 2006, 2 (106-109):
  • [2] VISUAL CHARACTERISTICS FOR EVALUATING THE DISCOMFORT GLARE - RELATIONSHIP BETWEEN THE POSITION, SIZE, ARRAY OF THE LED CHIPS, AND BCD ON THE DISCOMFORT GLARE
    Hara, N.
    PROCEEDINGS OF CIE 2016 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2016, : 704 - 707
  • [3] A Position Index Formula for Evaluation of Glare Source in the Visual Field
    Kim, Wonwoo
    Kim, Jeong Tai
    INDOOR AND BUILT ENVIRONMENT, 2011, 20 (01) : 47 - 53
  • [4] Calculation of the Discomfort Glare Position Index of a Light Source.
    Risthein, Endel
    1600, (57):
  • [5] Visual Comfort, Discomfort Glare, and Occupant Fenestration Control: Developing a Research Agenda
    Van Den Wymelenberg, Kevin G.
    LEUKOS, 2014, 10 (04) : 207 - 221
  • [6] Formulas for Calculating the Position Index in Determining the Glare Discomfort Coefficient.
    Ristkhein, E.M.
    Svetotehnika, 1983, (06): : 3 - 4
  • [7] Tolerance of discomfort glare from a large area source for work on a visual display
    Rodriquez, R. G.
    Pattini, A.
    LIGHTING RESEARCH & TECHNOLOGY, 2014, 46 (02) : 157 - 170
  • [8] Morphological and Position Factors of Vertical Surface Light Source Affecting Discomfort Glare Perception
    Kong, Guangyan
    Wang, Lixiong
    Chen, Peng
    Wang, Shuo
    Ma, Fengrui
    BUILDINGS, 2024, 14 (05)
  • [9] A distribution chart of glare sensation over the whole visual field
    Kim, Wonwoo
    Kim, Jeong Tai
    BUILDING AND ENVIRONMENT, 2010, 45 (04) : 922 - 928
  • [10] The Variation of the Glare Source Luminance According to the Average Luminance of Visual Field
    Kim, Wonwoo
    Kim, Jeong Tai
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (01) : 98 - 108