Determination of calculation parameters for difference approximation of group refractive index of air based on two-point central method

被引:1
|
作者
Wei, Dong [1 ]
Xiao, Muzheng [2 ]
Yang, Ping [3 ]
机构
[1] Nagaoka Univ Technol, Dept Mech Engn, Nagaoka, Niigata 9402188, Japan
[2] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
[3] Xiamen Univ, Sch Aerosp Engn, Dept Mech & Elect Engn, Xiamen 361006, Fujian, Peoples R China
基金
日本学术振兴会;
关键词
Group refractive index; Difference approximation; Frequency comb; Length measurement; Metrology; DISTANCE; LENGTH; LONG;
D O I
10.1186/s41476-018-0083-y
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Background: The accurate knowledge of the refractive index of air is very important for environmental compensation in length measurements. Methods: In this study, we apply difference approximation methods to facilitate the calculation of the group refractive index of air (GRA) over all calculable wavelengths. Our approach involves the determination of a suitable combination of the step size Delta lambda and numbers of significant digits of calculations of the phase refractive index of air (PRA) by balancing the two main errors (round-off and truncation errors) over the entire calculable wavelength range. Results: Based on our calculations, we find that the GRA computation over the range of all calculable wavelengths (301.5-1698.5 nm) can be easily approximated by the two-point central difference method with Delta lambda = 1.5 nm and 12-digit PRA accuracy. Conclusion: The approximation accuracy is less than 5 x 10(-9). Our approach can be used by non-expert users to obtain the GRA with sufficient accuracy.
引用
收藏
页数:7
相关论文
共 13 条