Setup errors in cone-beam computed tomography and their effects on acute radiation toxicity in cervical cancer radiotherapy

被引:11
|
作者
Xin, S. [1 ]
机构
[1] Hebei Med Univ, Tangshan Workers Hosp, Dept Radiol, Tangshan, Hebei, Peoples R China
关键词
Cervical cancer; Cone-beam computed tomography; Image-guided radiation therapy; Setup error;
D O I
10.4238/2015.September.21.4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study aimed to evaluate cone-beam computed tomography setup errors during cervical cancer treatment and the effects of these errors on acute radiation toxicity and treatment efficacy. A total of 170 cervical cancer patients were randomly divided into imageguided radiation therapy (IGRT; 86 patients) and intensity-modulated radiation therapy (IMRT; 84 patients) groups to receive IGRT and IMRT, respectively. After correcting setup errors for the 86 patients in the IGRT group, the X-, Y- and Z-axis errors were smaller than the corresponding errors before correction (P < 0.01, P < 0.05, and P < 0.05, respectively). The setup errors unevenly influenced the affected organs and dosage distributions in the targeted regions. The frequencies of patients with grade 0 or I urinary toxicity were 86.0% (74/86) and 44.0% (37/84) in the IGRT and IMRT groups, respectively (P < 0.01), whereas the frequencies of patients with grade 0 or I gastrointestinal toxicity were 83.7% (72/86) and 53.6% (45/84) in the IGRT and IMRT groups, respectively (P < 0.01). The two groups had similar response rates (P > 0.05). IGRT significantly corrected and reduced setup errors during cervical cancer treatment and enhanced the dosage distribution accuracy within the affected organs and targeted regions. IGRT can reduce the adverse effect of radiotherapy, thereby achieving improved efficacy during cervical cancer treatment.
引用
收藏
页码:10937 / 10943
页数:7
相关论文
共 50 条
  • [1] Implementing cone-beam computed tomography-guided online adaptive radiotherapy in cervical cancer
    Shelley, Charlotte E.
    Bolt, Matthew A.
    Hollingdale, Rachel
    Chadwick, Susan J.
    Barnard, Andrew P.
    Rashid, Miriam
    Reinlo, Selina C.
    Fazel, Nawda
    Thorpe, Charlotte R.
    Stewart, Alexandra J.
    South, Chris P.
    Adams, Elizabeth J.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2023, 40
  • [2] Set-up errors in prostate cancer radiotherapy based on cone-beam computed tomography.
    Trignani, M.
    Caponigro, G.
    Di Biase, M.
    Bagala, P.
    Falco, M. D.
    Vinciguerra, A.
    Augurio, A.
    Di Tommaso, M.
    Caravatta, L.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S723 - S723
  • [3] A prospective study to assess and quantify the setup errors with cone-beam computed tomography in head-and-neck cancer image-guided radiotherapy treatment
    Jain, Vidhi
    Soni, Tej Prakash
    Singh, Dinesh Kumar
    Patni, Nidhi
    Jakhotia, Naresh
    Gupta, Anil Kumar
    Gupta, Tara Chand
    Singhal, Harish
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (03) : 783 - 787
  • [4] Fractionated changes in prostate cancer radiotherapy using cone-beam computed tomography
    Huang, Tzung-Chi
    Chou, Kuei-Ting
    Yang, Shih-Neng
    Chang, Chih-Kai
    Liang, Ji-An
    Zhang, Geoffrey
    MEDICAL DOSIMETRY, 2015, 40 (03) : 222 - 225
  • [5] ACCURACY AND DOSE OF A CONE-BEAM COMPUTED TOMOGRAPHY FOR STEREOTACTIC RADIOSURGERY SETUP
    Sancho, I.
    Modolell, I.
    Ferrer, F.
    Lizuain, M. C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S422 - S422
  • [6] Accuracy and feasibility of cone-beam computed tomography for stereotactic radiosurgery setup
    Chang, Jenghwa
    Yenice, Kamil M.
    Narayana, Ashwatha
    Gutin, Philip H.
    MEDICAL PHYSICS, 2007, 34 (06) : 2077 - 2084
  • [7] Image-guided radiotherapy for liver cancer using respiratorycorrelated computed tomography and cone-beam computed tomography
    Guckenberger, Matthias
    Sweeney, Reinhart A.
    Wilbert, Juergen
    Krieger, Thomas
    Richter, Anne
    Baier, Kurt
    Mueller, Gerd
    Sauer, Otto
    Flentje, Michael
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : 297 - 304
  • [8] A Study on Image Guided Radiotherapy Using Cone-Beam Computed Tomography (CBCT) for Head and Neck Cancer IMRT Patient Setup
    Tang, X.
    Chera, B.
    Lian, J.
    Deschesne, K.
    Chang, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [10] Energy Spectrum of Electromagnetic Radiation for a Dual-Energy Cone-Beam Computed Tomography in Radiotherapy
    Baek, Seunghyeop
    Kim, Jin Sung
    Ahn, Woo Sang
    Ahn, Sohyun
    JOURNAL OF MAGNETICS, 2020, 25 (04) : 614 - 619