Modification of building energy simulation tool TRNSYS for modelling nonlinear heat and moisture transfer phenomena by TRNSYS/MATLAB integration

被引:4
|
作者
Nayak, Ajaya Ketan [1 ,2 ]
Hagishima, Aya [1 ]
机构
[1] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Dept Energy & Environm Engn, 6-1 Kasuga Koen, Kasuga, Fukuoka 8168580, Japan
[2] Kalinga Inst Ind Technol, Sch Mech Engn, Bhubaneswar 751024, Odisha, India
关键词
EVAPORATION; PERFORMANCE; ROOF;
D O I
10.1051/e3sconf/202017225009
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Software for numerical simulation of various types of energy used in buildings, i.e. building energy simulation (BES), have become an essential tool for recent research pertaining to building physics. TRNSYS is a well-known BES used in both academia and the construction industry for a wide range of simulations, such as the design and performance evaluation of buildings and related facilities for heating, cooling, and ventilation. TRNSYS has a modular structure comprising various components, and each component is interconnected and compiled through a common interface using a FORTRAN compiler. Its modular structure enables interactions with various external numerical simulation tools, such as MATLAB, Python, and ESP-r. For ordinary simulations of building energy load using TRNSYS, the generic module Type 56 is usually recommended, which provides detailed physics modelling of building thermal behaviours based on unsteady energy conservation equations and Fourier's law for each building material. However, Type 56 explicitly depends on the transfer function method to discretise the original differential equations; therefore, it cannot model nonlinear phenomena, such as latent heat and moisture transfer between a building surface and ambient air. In other words, the current TRNSYS cannot be used to estimate the effectiveness of evaporation during cooling, which is a typical passive design method. Hence, the authors developed a MATLAB/TRNSYS integration scheme, in which TRNSYS was modified to model simultaneous heat and moisture transfer from the wet roof surface of a building. This scheme enabled TRNSYS to calculate the rate of evaporative heat and moisture transfer dynamically from the roof surface, assuming a control volume approximation of the roof surface. Finally, the effect of evaporative cooling on the thermal performance of an Indian building was estimated using the modified model.
引用
收藏
页数:8
相关论文
共 5 条
  • [1] Retrofit strategies applied to a tertiary building assisted by Trnsys energy simulation tool
    Valdiserri, Paolo
    Biserni, Cesare
    Tosi, Giacomo
    Garai, Massimo
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 765 - 770
  • [2] Hospital CHCP system optimization assisted by TRNSYS building energy simulation tool
    Pagliarini, G.
    Corradi, C.
    Rainieri, S.
    APPLIED THERMAL ENGINEERING, 2012, 44 : 150 - 158
  • [3] Applicability of a heat and moisture transfer panel (HAMP) for maintaining space relative humidity in an office building using TRNSYS
    Eldeeb, Radia
    Fauchoux, Melanie
    Simonson, Carey J.
    ENERGY AND BUILDINGS, 2013, 66 : 338 - 345
  • [4] CO-SIMULATION BETWEEN ESP-R AND TRNSYS: MORE HIGHLY RESOLVED MODELLING OF INTEGRATED BUILDING AND ENERGY SYSTEMS
    Beausoleil-Morrison, Ian
    Macdonald, Francesca
    Kummert, Michael
    Jost, Romain
    McDowell, Tim
    BUILDING SIMULATION 2013: 13TH INTERNATIONAL CONFERENCE OF THE INTERNATIONAL BUILDING PERFORMANCE SIMULATION ASSOCIATION, 2013, : 3458 - 3465
  • [5] Dynamic heat transfer model of vertical green fa?ades and its co-simulation with a building energy modelling program in hot-summer/warm-winter zones
    Zhang, Yu
    Zhang, Lei
    Meng, Qinglin
    JOURNAL OF BUILDING ENGINEERING, 2022, 58