Extraction and quantification of SO2 content in wines using a hollow fiber contactor

被引:3
|
作者
Plaza, Andrea [1 ]
Romero, Julio [1 ]
Silva, Wladimir [1 ]
Morales, Elizabeth [1 ]
Torres, Alejandra [1 ]
Aguirre, Maria J. [2 ]
机构
[1] Univ Santiago Chile USACH, Lab Membrane Separat Proc LabProSeM, Santiago, Chile
[2] Univ Santiago Chile USACH, Lab Conduct Polymers, Santiago, Chile
关键词
Wines; sulfite; sulfur dioxide; membrane contactor; aspiration method; Ripper method; SULFUR-DIOXIDE; AMMONIA REMOVAL; TOTAL SULFITE; FOOD;
D O I
10.1177/1082013213494900
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Sulfites (SO32-) or sulfur dioxide (SO2) is a preservative widely used in fruits and fruit-derived products. This study aims to propose a membrane contactor process for the selective removal and recovery of SO2 from wines in order to obtain its reliable quantification. Currently, the aspiration and Ripper methods offer a difficult quantification of the sulfite content in red wines because they involve evaporation steps of diluted compounds and a colorimetric assay, respectively. Therefore, an inexpensive and accurate methodology is not currently available for continuous monitoring of SO2 in the liquids food industry. Red wine initially acidified at pH<1 was treated by membrane extraction at 25?. This operation is based on a hydrophobic Hollow Fiber Contactor, which separates the acidified red wine in the shell side and a diluted aqueous sodium hydroxide solution as receiving solution into the lumenside in countercurrent. Sulfite and bisulfite in the acidified red wine become molecular SO2, which is evaporated through the membrane pores filled with gas. Thus, SO2 is trapped in a colorless solution and the membrane contactor controls its transfer, decreasing experimental error induced in classical methods. Experimental results using model solutions with known concentration values of show an average extraction percentage of 98.91 after 4 min. On the other hand, two types of Chilean Cabernet Sauvignon wines were analyzed with the same system to quantify the content of free and total sulfites. Results show a good agreement between these methods and the proposed technique, which shows a lower experimental variability.
引用
收藏
页码:501 / 510
页数:10
相关论文
共 50 条
  • [1] Effects of SO2 on CO2 capture using a hollow fiber membrane contactor
    Yang, Jie
    Yu, Xinhai
    Yan, Jinyue
    Tu, Shan-Tung
    Dahlquist, Erik
    APPLIED ENERGY, 2013, 112 : 755 - 764
  • [2] Modelling of a hollow fibre ceramic contactor for SO2 absorption
    Luis, P.
    Garea, A.
    Irabien, A.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2010, 72 (02) : 174 - 179
  • [3] Modeling SO2 absorption into water accompanied with reversible reaction in a hollow fiber membrane contactor
    Yu, Hesheng
    The, Jesse
    Tan, Zhongchao
    Feng, Xianshe
    CHEMICAL ENGINEERING SCIENCE, 2016, 156 : 136 - 146
  • [4] Absorption of SO2 from flue gas using PVDF hollow fiber membranes in a gas-liquid contactor
    Park, Hyun Hee
    Deshwal, Bal Raj
    Kim, In Won
    Lee, Hyung Keun
    JOURNAL OF MEMBRANE SCIENCE, 2008, 319 (1-2) : 29 - 37
  • [5] Experimental studies on simultaneous removal of CO2 and SO2 in a polypropylene hollow fiber membrane contactor
    Lv, Yuexia
    Yu, Xinhai
    Tu, Shan-Tung
    Yan, Jinyue
    Dahlquist, Erik
    APPLIED ENERGY, 2012, 97 : 283 - 288
  • [6] Optimization of CO2 Absorption Characteristic under the Influence of SO2 in Flue Gas by Hollow Fiber Membrane Contactor
    Qu, Ziyi
    Zhang, Li
    Yan, Yunfei
    Ju, Shunxiang
    JOURNAL OF CHEMISTRY, 2016, 2016
  • [7] Application of seawater to enhance SO2 removal from simulated flue gas through hollow fiber membrane contactor
    Sun, Xueyan
    Meng, Fangang
    Yang, Fenglin
    JOURNAL OF MEMBRANE SCIENCE, 2008, 312 (1-2) : 6 - 14
  • [8] Absorption SO2 using PVDF hollow fiber membranes with PEG as an additive
    Park, Hyun-Hee
    Lim, Chun-Won
    Jo, Hang-Dai
    Choi, Won-Kil
    Lee, Hyung-Keun
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2007, 24 (04) : 693 - 697
  • [9] Absorption of SO2 using PVDF hollow fiber membranes with PEG as an additive
    Hyun-Hee Park
    Chun-Won Lim
    Hang-Dai Jo
    Won-Kil Choi
    Hyung-Keun Lee
    Korean Journal of Chemical Engineering, 2007, 24 : 693 - 697
  • [10] Preparation of PVDF Hollow Fiber Membrane and Absorption of SO2 from Flue Gas Using Bench Scale Gas-Liquid Contactor
    Park, Hyun-Hee
    Jo, Hang-Dae
    Kim, In-Won
    Lee, Hyung-Keun
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2008, 46 (03): : 521 - 528