A quasi-transient model of a transcritical carbon dioxide direct-expansion ground source heat pump for space and water heating

被引:23
|
作者
Eslami-Nejad, Parham [1 ]
Ouzzane, Mohamed [1 ]
Aidoun, Zine [1 ]
机构
[1] Nat Resources Canada, CanmetENERGY, Varennes, PQ J3X 1S6, Canada
关键词
Theoretical modeling; Ground source heat pump; Carbon dioxide; Direct expansion; Geothermal borehole; AIR-SOURCE; SYSTEM; PERFORMANCE; BOREHOLE;
D O I
10.1016/j.applthermaleng.2015.07.058
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, a theoretical quasi-transient model is developed for detailed simulations of a carbon dioxide (CO2) direct-expansion ground source heat pump (DX-GSHP). This model combines a transient analytical model for the ground, steady-state numerical models for the borehole and the gas cooler, as well as several thermodynamic models for the remaining components of a conventional heat pump, organized in interacting subroutines to form a powerful simulation tool. Extensive validation combining experimental data and CFD-generated results was performed for the borehole before the tool was used to simulate a practical application case. Performance is investigated for a system satisfying both space heating and domestic hot water requirements of a typical single family detached home in a cold climate region. The variation of different system parameters is also evaluated in this study. It is shown that CO2 DX-GSHPs can offer relatively efficient and stable performance for integrated water and space heating applications. Furthermore, the importance of an accurate geothermal borehole sizing is highlighted for the DX-CO2 heat pump systems. It is shown that, due to changes in the system working conditions, the total borehole length is not linearly correlated with the heat pump energy consumption and other parameters such as heat pump coefficient of performance and pressure drop in ground heat exchangers. Results showed that increasing the total borehole length of an optimum design (reference case study) by 25% decreases the total annual energy consumption by only 6%. However, reducing total borehole length of the reference case by 25% increases the total annual energy consumption by 10%. Crown Copyright (C) 2015 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:259 / 269
页数:11
相关论文
共 50 条
  • [1] A transient coupled model of a variable speed transcritical CO2 direct expansion ground source heat pump for space heating and cooling
    Nguyen, A.
    Elsami-Nejad, P.
    RENEWABLE ENERGY, 2019, 140 : 1012 - 1021
  • [2] Experimental study of a carbon dioxide direct-expansion ground source heat pump (CO2-DX-GSHP)
    Badache, Messaoud
    Ouzzane, Mohamed
    Eslami-Nejad, Parham
    Aidoun, Zine
    APPLIED THERMAL ENGINEERING, 2018, 130 : 1480 - 1488
  • [3] Energy and exergy investigation of a carbon dioxide direct-expansion geothermal heat pump
    Ghazizade-Ahsaee, Hossein
    Ameri, Mehran
    APPLIED THERMAL ENGINEERING, 2018, 129 : 165 - 178
  • [4] Experimental characterization of a transcritical CO2 direct expansion ground source heat pump for heating applications
    Bastani, Arash
    Eslami-Nejad, Parham
    Badache, Messaoud
    Alain Tuan Anh Nguyen
    ENERGY AND BUILDINGS, 2020, 212 (212)
  • [5] Experimental performance analysis of a direct-expansion ground source heat pump in Xiangtan, China
    Yang, Wei
    ENERGY, 2013, 59 : 334 - 339
  • [6] The Development of a Novel Direct-Expansion Ground Source Heat Pump (DE-GSHP) for Embankment Heating in Cold Regions
    Cao, Mingxing
    Zhang, Yimin
    Hu, Tianfei
    APPLIED SCIENCES-BASEL, 2023, 13 (19):
  • [7] Parametric study on the performance of a direct-expansion geothermal heat pump using carbon dioxide
    Austin, Brian T.
    Sumathy, K.
    APPLIED THERMAL ENGINEERING, 2011, 31 (17-18) : 3774 - 3782
  • [8] Study on a direct-expansion solar-assisted heat pump water heating system
    Kuang, YH
    Sumathy, K
    Wang, RZ
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (05) : 531 - 548
  • [9] Experimental performance analysis of 3RT small-scale direct-expansion ground-source heat pump for space heating and cooling
    Kim, Soyeon
    Jung, Minkyu
    Ku, Donik
    Na, Sun-Ik
    Lee, Gilbong
    Kim, Minsung
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2025, 39 (03) : 1573 - 1583
  • [10] Performance analysis of U-vertical direct-expansion ground-source heat pump
    Yang, Wei
    Zhou, Jin
    Zhang, Guoqiang
    Journal of Southeast University (English Edition), 2010, 26 (02) : 209 - 211