Design and experiment of CO2 high temperature spectrum parameter measurement system

被引:1
|
作者
Chen Jiu-Ying [1 ,2 ]
Zhou Mei [1 ]
Liu Jian-Guo [3 ]
Kan Rui-Feng [3 ]
Li Chuan-Rong [1 ]
机构
[1] Chinese Acad Sci, Key Lab Quantitat Remote Sensing Informat Technol, Acad Optoelect, Beijing 100094, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Key Lab Environm Opt & Technol, Anhui Inst Opt & Fine Mech, Hefei 230031, Anhui, Peoples R China
关键词
tunable diode laser absorption spectroscopy (TDLAS); high-temperature spectrum; intensity; self-broadening full-width; temperature-dependence exponent; LASER-ABSORPTION; (CO2)-C-12-O-16;
D O I
10.11972/j.issn.1001-9014.2019.03.017
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
CO2 and CO2 are called the key indicators of combustion efficiency. Accurate measurement of CO2 in the combustion flow field is very important for energy conservation and emission reduction in industrial combustion process and engine combustion state diagnosis. Researching intensity, self-broadening full-width, temperature-dependence exponent and other parameters of CO2 in high temperature, may improve the accuracy and reliability of measurements for CO2 concentration. A precise temperature control and pressure control gas spectroscopic parameter measurement system with a design temperature up to 2073 K based on absorption spectroscopy has been developed for the measurement of spectroscopic parameters of the R (50e) line at 5 007.787cm(-1) of CO2. Many high temperature survey spectra of the CO2 R (50e) line were recorded at 1 212 similar to 1 873 K and many pressures through the system. Through background subtraction, baseline fitting, time-frequency conversion, multi-line combination and nonlinear least squares fitting, and other data processing based on the CO2 R (50e) survey spectra, intensity, self-broadening full-width and temperature-dependence exponent at 1 212-1 873 K were obtained. The uncertainty of line strength is less than 1.5%, the uncertainty of self-broadening full-width is less than 4. 5%. These parameters are supplement and improvement to the existing database. They are helpful for the detection of CO2 concentration in combustion diagnosis to ensure the accurate inversion of CO2 concentration in the combustion process.
引用
收藏
页码:358 / 364
页数:7
相关论文
共 17 条
  • [1] Bevington P.R., 1969, DATA REDUCTION ERROR, P58
  • [2] CHEN Jiu-Ying, 2013, ACTA PHYS SINICA, V62, P212
  • [3] CHEN Jiu- Ying, 2016, SPIE OPTICAL ENG APP
  • [4] CHEN Jiu- Ying, 2012, CHINESE J LASERS, V39, P112
  • [5] Thermodynamic Modeling and Experimental Study of CO2 Dissolution in New Absorbents for Post-Combustion CO2 Capture Processes
    Coulier, Y.
    Lowe, A. R.
    Coxam, J. -Y.
    Ballerat-Busserolles, K.
    [J]. ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (01): : 918 - 926
  • [6] Compact optical probe for flame temperature and carbon dioxide using interband cascade laser absorption near 4.2 μm
    Girard, J. J.
    Spearrin, R. M.
    Goldenstein, C. S.
    Hanson, R. K.
    [J]. COMBUSTION AND FLAME, 2017, 178 : 158 - 167
  • [7] Infrared laser-absorption sensing for combustion gases
    Goldenstein, Christopher S.
    Spearrin, R. Mitchell
    Jeffries, Jay B.
    Hanson, Ronald K.
    [J]. PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2017, 60 : 132 - 176
  • [8] Kai Sun, 2013, MEASUREMENT SCI TECH, V24, P5203
  • [9] Li H., 2008, Journal of the Combustion Society of Japan, V50, P289
  • [10] Cryogenic cell for low-temperature spectral experiments of atmospheric molecules
    Ma, Hong-Liang
    Sun, Ming-Guo
    Cao, Zhen-Song
    Huang, Yin-Bo
    Wang, Gui-Shi
    Gao, Xiao-Ming
    Rao, Rui-Zhong
    [J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2014, 22 (10): : 2617 - 2621