Development of a sensitive and stable GC-MS/MS method for simultaneous determination of four N-nitrosamine genotoxic impurities in sartan substances

被引:28
|
作者
Liu, Jie [1 ]
Xie, Bin [1 ]
Mai, Binliang [2 ]
Cai, Qiang [1 ]
He, Rujian [2 ]
Guo, Dong [2 ,3 ]
Zhang, Zhifeng [2 ]
Fan, Jun [2 ]
Zhang, Weiguang [2 ]
机构
[1] Zhuhai Rundu Pharmaceut Co Ltd, Zhuhai 519040, Peoples R China
[2] South China Normal Univ, Sch Chem, Guangzhou 510006, Peoples R China
[3] Guangzhou Res & Creat Biotechnol Co Ltd, Guangzhou 510663, Peoples R China
基金
中国国家自然科学基金;
关键词
Sartan substances; N-nitrosamine genotoxic impurity; GC-MS/MS; Multiple reactions monitoring; Quantitative determination; TANDEM MASS-SPECTROMETRY; ELECTRON IONIZATION; BY-PRODUCTS; WATER; EXTRACTION;
D O I
10.1186/s40543-020-00254-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Recently, N-nitrosamines have been unexpectedly found in generic sartan products. Herein, we developed a sensitive and stable GC-MS/MS method with multiple reactions monitoring mode for the simultaneous determination of four N-nitrosamines in sartan substances, namely, N-nitrosodimethylamine, N-nitrosodiethylamine, N-nitrosodibutylamine, and N-nitrosodiisopropylamine. The conditions of gas chromatography and mass spectrometry were optimized. The method was validated according to the International Council for Harmonization guidelines in terms of sensitivity, linearity, accuracy, precision, specificity, and stability. The limits of detection of N-nitrosamines in sartan substances ranged from 0.002 to 0.150 ppm, and the corresponding limits of quantification were in the range of 0.008-0.500 ppm, which met the sensitivity requirements for the limits set by the Food and Drug Administration of the United States. The internal standard curve of four N-nitrosamines showed good linearity of regression coefficients over 0.99. The recoveries of N-nitrosamines in selected sartan drugs ranged from 87.68 to 123.76%. The intraday and interday relative standard deviation values were less than 9.15%. Therefore, this proposed method exhibited good sensitivity and precision, high accuracy, and fast analysis speed, which provide a reliable method for quality control of N-nitrosamines in sartan products.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Development of a sensitive and stable GC-MS/MS method for simultaneous determination of four N-nitrosamine genotoxic impurities in sartan substances
    Jie Liu
    Bin Xie
    Binliang Mai
    Qiang Cai
    Rujian He
    Dong Guo
    Zhifeng Zhang
    Jun Fan
    Weiguang Zhang
    Journal of Analytical Science and Technology, 12
  • [2] Screening of Nitrosamine Impurities in Sartan Pharmaceuticals by GC-MS/MS
    Chang, Shu-Han
    Ho, Hui-Yu
    Zang, Chi-Zong
    Hsu, Ya-Hui
    Lin, Mei-Chih
    Tseng, Su-Hsiang
    Wang, Der-Yuan
    MASS SPECTROMETRY LETTERS, 2021, 12 (02) : 31 - 40
  • [3] Development of GC-MS/MS Method for Simultaneous Estimation of Four Nitrosoamine Genotoxic Impurities in Valsartan
    Tummala, Sambasiva Rao
    Amgoth, Krishnamanjari Pawar
    TURKISH JOURNAL OF PHARMACEUTICAL SCIENCES, 2022, 19 (04) : 455 - 461
  • [4] Development and Validation of a Sensitive GC-MS/MS Method for the Determination of Five Potential Genotoxic Impurities in Abiraterone Acetate
    Zhong, ZhenHua
    Chen, YuPing
    Xia, HongYing
    Chen, ZhenZhen
    Cheng, QiZhen
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (02) : 105 - 110
  • [5] Simultaneous Determination of Genotoxic Impurities in Fudosteine Drugs by GC-MS
    Gooty, Amarnatha Reddy
    Katreddi, Hussain Reddy
    Reddy, Raghavender S.
    Hunnur, Raveendra K.
    Sharma, Hemant Kumar
    Masani, Narendra Kumar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (08) : 1277 - 1281
  • [6] A Sensitive and Selective GC-MS Method for Analysis of Genotoxic Impurities in Dobutamine Hydrochloride
    Maddalaaddala, Vijaya Lakshmi
    Ray, P. C.
    Rao, K. M. V. N.
    ORIENTAL JOURNAL OF CHEMISTRY, 2016, 32 (03) : 1685 - 1690
  • [7] Development of a Sensitive Screening Method for Simultaneous Determination of Nine Genotoxic Nitrosamines in Active Pharmaceutical Ingredients by GC-MS
    Witkowska, Anna B.
    Giebultowicz, Joanna
    Dabrowska, Magdalena
    Stolarczyk, Elzbieta U.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (20)
  • [8] Determination of nitrobenzene potential genotoxic impurities in nifedipine with GC-MS
    Zhao, Xinyu
    Li, Caixia
    Zeng, Hongxia
    Gu, Xiao
    Zheng, Jinqi
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 248
  • [9] A Validated GC-MS Method for the Determination of Genotoxic Impurities in Divalproex Sodium Drug Substance
    Reddy, S. Raghavender
    Reddy, K. Hussain
    Kumar, M. Narendra
    Reddy, P. Madhava
    Reddy, J. Venkata Ramana
    Sharma, Hemant Kumar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2019, 57 (02) : 101 - 107
  • [10] A selective and sensitive LC-MS/MS method for the simultaneous determination of twopotential genotoxic impurities in celecoxib
    Vijaya Bhaskar Reddy A.
    Venugopal N.
    Madhavi G.
    Journal of Analytical Science and Technology, 5 (1)