Analysis of Uncertainties in Clinical High-Energy Photon Beam Calibrations Using Absorbed Dose Standards

被引:1
|
作者
Elbashir, Fawzia E. M. [1 ]
Ksouri, Wassim [2 ]
Habbani, Farouk [3 ]
El-Khayatt, Ahmed M. [4 ]
Eisa, Mohamed Hassan [4 ]
Suliman, Ibrahim I. [4 ,5 ]
机构
[1] Univ Gezira, Natl Canc Inst, Dept Med Phys, POB 20, Wad Madani, Sudan
[2] Ctr Radiotherapie Hartmann 4, Dept Med Phys, Rue Kleber,CS90004, F-92309 Levallois Perret, France
[3] Univ Khartoum, Fac Sci, Dept Phys, POB 321, Khartoum, Sudan
[4] Imam Mohammad Ibn Saud Islamic Univ IMSIU, Coll Sci, Dept Phys, Riyadh 11642, Saudi Arabia
[5] Sudan Atom Energy Commiss, Radiat & Nucl Safety Inst, POB 3001, Khartoum, Sudan
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 08期
关键词
radiotherapy; radiation dosimetry; ionization chamber; Linac; absorbed dose to water; dosimetry protocols; DOSIMETRY; WATER; CODE;
D O I
10.3390/app12083857
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We compared the results of absorbed dose measurements made using the TRS-398, TG-51, and DIN protocols and their associated uncertainties to reduce discrepancies in measurement results made using the three protocols. This experiment was carried out on two Varian Medical linear accelerators with 4, 6, 10, and 20 MV photon energies using FC65-G and CC15 (cylindrical) and NACP-02-type (plane-parallel) ion chambers in water phantoms. The radiation beam quality index (Q) was determined from the measurement of percentage depth dose. It was used to determine the photon beam quality factor required with the ionization chamber calibration factor to convert the ion chamber reading into the absorbed dose to water. For the same beam quality, the TRS-398/TG-51 varied from 0.01% to 1.8%, whereas the ratio for TRS-398/DIN 6800-2 varied from 0.1% to 0.88%. The chamber-to-chamber variation was 0.09% in TRS-398/TG-51, 0.03% in TRS-398/DIN, and 0.02% in TG-51/DIN 6800-2. The expanded uncertainties (k = 1) were 1.24 and 1.25 when using TRS-398 and DIN 6800-2, respectively. Using the aforementioned three protocols, the results showed little chamber-to-chamber variation and uncertainty in absorbed dose measurements. The estimated uncertainties when using cylindrical ion chambers were slightly lower than those measured using plane-parallel chambers. The results are important in facilitating comparisons of absorbed dose measurements when using the three protocols.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Dosimetry of high-energy photon beams based on standards of absorbed dose to water
    McDonald, JC
    HEALTH PHYSICS, 2002, 82 (05): : 751 - 752
  • [2] ABSORBED DOSE BEAM QUALITY FACTORS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON BEAMS
    ANDREO, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (12): : 2189 - 2211
  • [3] COMPARISON OF THE NMIJ AND THE ARPANSA STANDARDS FOR ABSORBED DOSE TO WATER IN HIGH-ENERGY PHOTON BEAMS
    Shimizu, M.
    Morishita, Y.
    Kato, M.
    Tanaka, T.
    Kurosawa, T.
    Takata, N.
    Saito, N.
    Ramanathan, G.
    Harty, P. D.
    Oliver, C.
    Wright, T.
    Butler, D. J.
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 181 - 186
  • [4] ABSORBED-DOSE CALIBRATIONS IN HIGH-ENERGY PHOTON BEAMS AT THE NATIONAL-PHYSICAL-LABORATORY - CONVERSION PROCEDURE
    BURNS, JE
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10): : 1555 - 1575
  • [5] TRANSFER PROCEDURES FOR HIGH-ENERGY X-RAY ABSORBED DOSE CALIBRATIONS
    BURNS, JE
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (05): : 950 - 950
  • [6] Evaluation of factors to convert absorbed dose calibrations from graphite to water for the NPL high-energy photon calibration service
    Nutbrown, RF
    Duane, S
    Shipley, DR
    Thomas, RAS
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (03): : 441 - 454
  • [7] High Accuracy Measurement of Absorbed Dose to Water Using Optically Stimulated Luminescence Dosimeter in High-Energy Photon Beam Field
    Goto, S.
    Hayashi, H.
    Yamaguchi, H.
    Shimizu, M.
    Akino, R.
    Sekiguchi, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E789 - E789
  • [8] Advances in the determination of absorbed dose to water in clinical high-energy photon and electron beams using ionization chambers
    Huq, MS
    Andreo, P
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (04): : R49 - R104
  • [9] A COMPARISON OF ABSORBED DOSE STANDARDS FOR HIGH-ENERGY X-RAYS
    SHORTT, KR
    ROSS, CK
    SCHNEIDER, M
    HOHLFELD, K
    ROOS, M
    PERROCHE, AM
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (12): : 1937 - 1955
  • [10] CONSISTENCY IN THE DETERMINATION OF ABSORBED DOSE TO WATER IN HIGH-ENERGY PHOTON BEAMS
    MIJNHEER, B
    MEDICAL PHYSICS, 1986, 13 (05) : 780 - 780