Static Calibration and Dynamic Behaviour of a Six-Component Force Balance for Variable Pressure Water Tunnel Facilities

被引:3
|
作者
Butler, D. [1 ]
Smith, S. M. [1 ]
Brandner, P. A. [1 ]
Clarke, D. B. [1 ]
Pearce, B. W. [1 ]
机构
[1] Maritime Div, Def Sci & Technol Grp, 506 Lorimer St, Fishermans Bend, Vic 3207, Australia
关键词
Calibration; Force-Balance; Six-component;
D O I
10.1007/s40799-020-00407-3
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The presented six component force balance is a novel design used for many of the force measurements on hydrofoils and other bodies in the University of Tasmania's cavitation tunnel. This balance is a versatile piece of equipment, the distribution of its six load cells gives it a high degree of sensitivity and stiffness in all directions. The accuracy of the balance in operating conditions has yet to be defined and its use for investigations of low frequency fluid-structure interactions warrants an analysis of its dynamic properties. This paper outlines a critical analysis of the balances calibration methodologies and its measurement uncertainties. A dynamic vibration model was built and validated with finite element modelling and experiment to give a prediction of the force balances natural frequencies and how they change with different test article mass and added masses. These results provide confidence in the data produced by this device and guide future experimental investigations into fluid structure interactions.
引用
收藏
页码:157 / 167
页数:11
相关论文
共 25 条
  • [1] Static Calibration and Dynamic Behaviour of a Six-Component Force Balance for Variable Pressure Water Tunnel Facilities
    D. Butler
    S. M. Smith
    P. A. Brandner
    D. B. Clarke
    B. W. Pearce
    Experimental Techniques, 2021, 45 : 157 - 167
  • [2] Correction to: Static Calibration and Dynamic Behaviour of a Six-Component Force Balance for Variable Pressure Water Tunnel Facilities
    D. Butler
    S.M. Smith
    P.A. Brandner
    D.B. Clarke
    B.W. Pearce
    Experimental Techniques, 2021, 45 : 703 - 703
  • [3] Static Calibration and Dynamic Behaviour of a Six-Component Force Balance for Variable Pressure Water Tunnel Facilities (Jan, 10.1007/s40799-020-00407-3, 2021)
    Butler, D.
    Smith, S. M.
    Brandner, P. A.
    Clarke, D. B.
    Pearce, B. W.
    EXPERIMENTAL TECHNIQUES, 2021, 45 (05) : 703 - 703
  • [4] Hybrid calibration method for six-component force/torque transducers of wind tunnel balance based on support vector machines
    Ma Yingkun
    Xie Shilin
    Zhang Xinong
    Luo Yajun
    Chinese Journal of Aeronautics , 2013, (03) : 554 - 562
  • [5] Hybrid calibration method for six-component force/torque transducers of wind tunnel balance based on support vector machines
    Ma Yingkun
    Xie Shilin
    Zhang Xinong
    Luo Yajun
    Chinese Journal of Aeronautics, 2013, 26 (03) : 554 - 562
  • [6] Hybrid calibration method for six-component force/torque transducers of wind tunnel balance based on support vector machines
    Ma Yingkun
    Xie Shilin
    Zhang Xinong
    Luo Yajun
    CHINESE JOURNAL OF AERONAUTICS, 2013, 26 (03) : 554 - 562
  • [7] Six-component force sensor and its calibration system
    Li, PY
    Tan, DP
    Liu, G
    Ying, MY
    2005 IEEE Networking, Sensing and Control Proceedings, 2005, : 889 - 893
  • [8] Calibration design evaluations through computational analysis and investigation of a six-component wind tunnel balance
    Rohit Kumar
    B N Ravi Srivatsa
    Balaji Subramanian
    ISSS Journal of Micro and Smart Systems, 2021, 10 (1) : 7 - 31
  • [9] Design methodology of a six-component balance for measuring forces and moments in water tunnel tests
    Nouri, N. M.
    Mostafapour, Karim
    Kamran, Maryam
    Bohadori, Robab
    MEASUREMENT, 2014, 58 : 544 - 555
  • [10] Design and calibration method for a novel six-component piezoelectric balance
    Jia, Zhenyuan
    Gao, Yifei
    Ren, Zongjin
    Gao, Shengnan
    Shang, Yongyan
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2013, 227 (08) : 1841 - 1852