Analysis on Parameters of Wood-frame Model under Impact Loading

被引:0
|
作者
Li, Cuiling [1 ]
Qu, Shuying [1 ]
Wu, Ruoyang [2 ]
Meng, Fanbo [1 ]
机构
[1] Yantai Univ, Dept Civil Engn, Yantai 264005, Peoples R China
[2] Southeast Univ, Dept Civil Engn, Nanjing 210096, Peoples R China
关键词
design model; finite element modeling; section parameter; deflection; stress;
D O I
10.4028/www.scientific.net/AMM.438-439.779
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Deflection and stress of different cross section forms and its value are compared by finite element analysis of timberwork design model under the impact loading. The result indicates that decreasing the size of cross section or changing the section shape can effectively avoid the model too heavy and conservative design. In the case of horizontal loads applied on first floor, strengthening the column of first floor obviously reduces the deflection of model and improves the lateral stiffness. Keeping the column size of the first floor and choosing I-section significantly reduce the overall weight on condition of meeting the bearing capacity and stability, it also make the material higher utilization.
引用
收藏
页码:779 / +
页数:2
相关论文
共 50 条
  • [1] WOOD-FRAME CONSTRUCTION
    BRINCK, G
    PROGRESSIVE ARCHITECTURE, 1991, 72 (08): : 37 - 40
  • [2] Finite-Element Analysis of Wood-Frame Houses under Lateral Loads
    Quayyum, Shahriar
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (12)
  • [3] Sensitivity of Wood-Frame Shear Wall Collapse Performance to Variations in Hysteretic Model Parameters
    Jayamon, Jeena R.
    Line, Philip
    Charney, Finley A.
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (01)
  • [4] Validation of seismic design parameters for wood-frame shearwall systems
    Ceccotti, A
    Karacabeyli, E
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2002, 29 (03) : 484 - 498
  • [5] The influence of the joint between the basement wall and the wood-frame wall on the airtightness of wood-frame houses
    Relander, Thor-Oskar
    Heiskel, Bjornar
    Tyssedal, John Solve
    ENERGY AND BUILDINGS, 2011, 43 (06) : 1304 - 1314
  • [6] Behavior of Cellulosic Fiber Board Wood-Frame Shear Walls with and without Openings under Cyclical Loading
    Musselman, Eric S.
    Dinehart, David W.
    Fitzpatrick, Thomas
    Zabel, Richard
    BUILDINGS, 2024, 14 (10)
  • [7] Development of a Wood-Frame Shear Wall Model in ABAQUS
    Xu, Jian
    Dolan, J. Daniel
    JOURNAL OF STRUCTURAL ENGINEERING, 2009, 135 (08) : 977 - 984
  • [8] Nationwide Earthquake Risk Model for Wood-Frame Houses in Canada
    Goda, Katsuichiro
    FRONTIERS IN BUILT ENVIRONMENT, 2019, 5
  • [9] Wood-frame residential buildings in Canada
    Mehaffey, JR
    COST ACTION E5 WORKSHOP ON FIRE SAFETY OF MEDIUM-RISE TIMBER FRAME RESIDENTIAL BUILDINGS, 1998, 179 : 127 - 138
  • [10] Analysis of hygrothermal performance for standard wood-frame structures in Korea
    Chang S.J.
    Kang Y.
    Wi S.
    Jeong S.-G.
    Kim S.
    Journal of the Korean Wood Science and Technology, 2016, 44 (03): : 440 - 448