Coagulation and chromogenic assays of factor VIII activity: General aspects, standardization, and recommendations

被引:77
|
作者
Barrowcliffe, TW [1 ]
Raut, S [1 ]
Sands, D [1 ]
Hubbard, AR [1 ]
机构
[1] Natl Inst Biol Stand & Controls, Potters Bar EN6 3QG, Herts, England
来源
SEMINARS IN THROMBOSIS AND HEMOSTASIS | 2002年 / 28卷 / 03期
关键词
factor VIII; assays; standards; recommendations;
D O I
10.1055/s-2002-32658
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Factor VIII (FVIII) is assayed by one-stage and two-stage clotting methods and by chromogenic methods, although the chromogenic method has largely replaced the two-stage clotting assay. Clinical plasma samples are assayed mostly by one-stage assays, but most manufacturers of concentrates use the chromogenic method, which is more precise and is the reference method of the European Pharmacopoeia and the International Society on Thrombosis and Haemostasis (ISTH). For most plasma-derived concentrates, assays against the World Health Organization (WHO) concentrate standard give similar results with the one-stage and chromogenic methods, but for products produced by the "method M" monoclonal antibody process, the one-stage potency is 25 to 30% higher than the chromogenic potency. For full-length recombinant products assayed against a plasma-derived concentrate standard, one-stage potencies are about 10% lower than chromogenic potencies, but for the B-domain deleted recombinant product ReFacto(R), the discrepancy is larger-from 20 to 50%. These discrepancies emphasize the need for an international methodology for labeling of concentrates. In ex vivo assays of hemophilic plasmas after infusion of concentrates, large discrepancies are found among laboratories and with different assay methods when a plasma standard is used. In most studies, the chromogenic potencies are higher than the one-stage potencies, and the discrepancy is highest for recombinant products. This discrepancy can be largely, eliminated by the use of concentrate standards, diluted in FVIII-deficient plasma, to assay postinfusion plasma samples.
引用
收藏
页码:247 / 255
页数:9
相关论文
共 50 条
  • [1] Determination of coagulation factor VIII activity by a chromogenic substrate method on STA, an automated coagulation analyzer
    Kleinveld, HA
    Andersson, NE
    Van Voorthuizen, H
    Den Hartog, J
    De Groot, PG
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1999, 59 (05): : 335 - 341
  • [2] A critical appraisal of one-stage and chromogenic assays of factor VIII activity
    Peyvandi, F.
    Oldenburg, J.
    Friedman, K. D.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2016, 14 (02) : 248 - 261
  • [3] Assay design and use of chromogenic factor VIII assays
    Rosen, S.
    HAEMOPHILIA, 2010, 16 : 82 - 82
  • [4] PROBLEMS IN THE STANDARDIZATION OF FACTOR-VIII ASSAYS
    KIRKWOOD, TBL
    SCANDINAVIAN JOURNAL OF HAEMATOLOGY, 1980, 25 : 110 - 115
  • [5] Chromogenic factor VIII activity assay
    Moser, Karen A.
    Funk, Dorothy M.
    AMERICAN JOURNAL OF HEMATOLOGY, 2014, 89 (07) : 781 - 783
  • [6] ASSESSING FACTOR VIII ACTIVITY IN THE PRESENCE OF MIM8 VIA CHROMOGENIC ASSAYS
    Pickering, W.
    Robinson, M.
    Cogswell, C.
    Clausen, W. H. O.
    Ezban, M.
    HAEMOPHILIA, 2022, 28 : 26 - 26
  • [7] STANDARDIZATION OF ASSAYS OF FACTOR-VIII AND FACTOR-IX
    BARROWCLIFFE, TW
    RESEARCH IN CLINIC AND LABORATORY, 1990, 20 (02): : 155 - 165
  • [8] Verification and Comparison of Chromogenic Factor VIII Activity Assays in Patients With Hemophilia Treated With and Without Emicizumab
    Lee, Min Young
    Lee, Woo In
    Kang, So Young
    Kim, Myeong Hee
    Park, Young Shil
    ANNALS OF LABORATORY MEDICINE, 2023, 43 (01) : 96 - 99
  • [9] Factor VIII Activity and Factor VIII Inhibitors Can Be Measured Accurately in Plasma Containing Mim8 by Using Specific Chromogenic Assays
    Pickering, William
    Robinson, Mary
    Cogswell, Caroline
    Clausen, Wan Hui Ong
    Weldingh, Karin Nana
    Ezban, Mirella
    HAEMOPHILIA, 2025,
  • [10] CURRENT ASPECTS ON EVALUATION OF ASSAYS OF FACTOR-VIII ACTIVITY, FACTOR-VIII ASSOCIATED PROTEIN AND FACTOR-VIII NEUTRALIZING ANTIBODY
    HINTZ, G
    BLUT, 1978, 36 (02): : 95 - 107