REPAIR OF DAMAGED PRECAST BRIDGE COLUMNS WITH GROUTED SPLICE SLEEVE CONNECTIONS USING CFRP SHELLS AND PLASTIC HINGE RELOCATION

被引:0
|
作者
Parks, Joel E. [1 ]
Brown, Dylan N. [2 ]
Ameli, M. J. [1 ]
Pantelides, Chris P. [1 ]
机构
[1] Univ Utah, Dept Civil & Environm Engn, 110 Cent Campus Dr, Salt Lake City, UT 84112 USA
[2] Michael Baker Int, Madison, WI 53719 USA
关键词
Accelerated Bridge Construction; FRP composite; repair; plastic hinge relocation; seismic; RC COLUMNS; SEISMIC RETROFIT;
D O I
暂无
中图分类号
TB33 [复合材料];
学科分类号
摘要
A repair technique has been developed to relocate the column plastic hinge of severely damaged precast reinforced concrete (RC) bridge columns. The technique utilizes a combination of a prefabricated carbon fiber-reinforced polymer (CFRP) shell with additional wet layup CFRP layers, epoxy anchored headed mild steel bars and nonshrink concrete. Undamaged columns with two different mechanical connector systems were initially tested to failure using cyclic quasi-static lateral loads. One connection system was used to connect a RC bridge pier cap to a column and a second connection system was used to connect a RC footing to a column. Failure of the two original specimens occurred at drift ratios between 6% and 7% with longitudinal bars fracturing in the column plastic hinge region. Subsequently, the column plastic hinge region was repaired by increasing the column cross-section from an octagonal section to a circular section and thus enlarging the column size from 53 cm to 76 cm up to a height equal to 46 cm. The repair was constructed using a prefabricated CFRP shell with additional wet layup CFRP layers. Headed mild steel bars were epoxy anchored into the pier cap and footing inside the CFRP shell. Nonshrink concrete was used to fill the void between the original columns and CFRP shell. Compared to the undamaged assemblies, the repaired specimens failed at the same drift ratio and at greater ultimate lateral loads. The plastic hinge was successfully relocated at the column section adjacent to the repair and the failure mode was bar fracture in the relocated plastic hinge region. The method is a viable technique for seismic repair or seismic retrofit of precast assemblies with severe damage in column to footing or column to pier cap connections.
引用
收藏
页数:10
相关论文
共 21 条
  • [1] Seismic Repair of Severely Damaged Precast Reinforced Concrete Bridge Columns Connected with Grouted Splice Sleeves
    Parks, Joel E.
    Brown, Dylan N.
    Ameli, M. J.
    Pantelides, Chris P.
    ACI STRUCTURAL JOURNAL, 2016, 113 (03) : 615 - 626
  • [2] Seismic Repair of Circular Reinforced Concrete Bridge Columns by Plastic Hinge Relocation with Grouted Annular Ring
    Krish, Zachary F.
    Kowalsky, Mervyn J.
    Nau, James M.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2021, 25 (12) : 2371 - 2405
  • [3] Shear strength and cracking mechanism of precast bridge columns with grouted sleeve connections
    Han, Qiang
    Li, Xiaopeng
    Xu, Kun
    Lu, Yanqiu
    Du, Xiuli
    Wang, Zhiqiang
    ENGINEERING STRUCTURES, 2021, 230
  • [4] Testing and Analysis of Precast Columns with Grouted Sleeve Connections and Shifted Plastic Hinging
    Haber, Zachary B.
    Mackie, Kevin R.
    Al-Jelawy, Haider M.
    JOURNAL OF BRIDGE ENGINEERING, 2017, 22 (10)
  • [5] Analytical Models for Seismic Repair of Bridge Columns Using Plastic Hinge Relocation
    Wu, Ruo-Yang
    Pantelides, Chris P.
    STRUCTURES CONGRESS 2018: BRIDGES, TRANSPORTATION STRUCTURES, AND NONBUILDING STRUCTURES, 2018, : 296 - 307
  • [6] Seismic Analysis of Precast Concrete Bridge Columns Connected with Grouted Splice Sleeve Connectors
    Ameli, M. J.
    Pantelides, Chris P.
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (02)
  • [7] Rapid repair and replacement of earthquake-damaged concrete columns using plastic hinge relocation
    Wu, Ruo-Yang
    Pantelides, Chris P.
    COMPOSITE STRUCTURES, 2017, 180 : 467 - 483
  • [8] Precast Concrete Bridge Column-Footing Connections with Recessed Grouted Splice Sleeve Connectors
    Barton, Ryan D.
    Ameli, M. J.
    Pantelides, Chris P.
    ACI STRUCTURAL JOURNAL, 2022, 119 (01) : 215 - 226
  • [9] Evaluation and repair of precast RC bridge column connections utilizing grouted splice sleeves
    Ameli, M. J.
    Parks, J. E.
    Brown, D. N.
    Pantelides, C. P.
    Reaveley, L. D.
    EURODYN 2014: IX INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, 2014, : 275 - 282
  • [10] Repair of Reinforced Concrete Bridge Columns Containing Buckled and Fractured Reinforcement by Plastic Hinge Relocation
    Rutledge, Stephen T.
    Kowalsky, Mervyn J.
    Seracino, Rudolf
    Nau, James M.
    JOURNAL OF BRIDGE ENGINEERING, 2014, 19 (08)