Quantitative bioluminescence imaging of transgene expression in vivo

被引:43
|
作者
Rettig, Garrett R. [1 ]
McAnuff, Marie [1 ]
Liu, Dijie [1 ]
Kim, Ji-Seon [1 ]
Rice, Kevin G. [1 ]
机构
[1] Univ Iowa, Div Med & Nat Prod Chem, Coll Pharm, Iowa City, IA 52242 USA
关键词
bioluminescent imaging (BLI); hydrodynamic dosing; nonviral gene delivery;
D O I
10.1016/j.ab.2006.04.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bioluminescent imaging (BLI) is a widely used in vivo method to determine the location and relative intensity of luciferase expression in mice. Luciferase expression is observed following an i.p. dose Of D-luciferin, resulting in bioluminescence that is detected in anesthetized mice by a charge-coupled device camera. To establish whether BLI could be used as a quantitative measurement of non-viral-mediated luciferase expression, precise quantities of plasmid DNA encoding the luciferase gene were hydrodynamically dosed in mice. The results established a linear correlation between the DNA dose and the BLI response measured in liver which spanned five orders of magnitude. The level of luciferase expression was found to be a direct function Of D-luciferin dose. The time course of luciferase expression and the influence of multiclosing of substrate were measured by BLI. The recovery of luciferase from the liver of hydrodynamically dosed mice allowed calibration of the BLI measurements. The results establish BLI's limit-of-detection at 20 pg of luciferase per liver following a hydrodynamic dose of 100 pg of plasmid DNA. These results demonstrate that BLI is both sensitive and linear and should allow for the direct comparison of the efficiency of gene transfer vectors that target the liver. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:90 / 94
页数:5
相关论文
共 50 条
  • [1] Quantitative Bioluminescence Imaging of Transgene Expression In Vivo
    Rettig, Garrett R.
    McAnuff, Marie
    Liu, Dijie
    Kim, Ji-Seon
    Rice, Kevin G.
    MOLECULAR THERAPY, 2006, 13 : S154 - S154
  • [2] Quantitative bioluminescence imaging of transgene expression in intact porcine antral follicles in vitro
    Jung, Song-yi
    Willard, Scott T.
    REPRODUCTIVE BIOLOGY AND ENDOCRINOLOGY, 2014, 12
  • [3] Quantitative bioluminescence imaging of transgene expression in intact porcine antral follicles in vitro
    Song-yi Jung
    Scott T Willard
    Reproductive Biology and Endocrinology, 12
  • [4] Bioluminescence imaging of Arc expression in vivo
    Izumi, Hironori
    Ishimoto, Tetsuya
    Mori, Hisashi
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2011, 115 : 228P - 228P
  • [5] Advances in vivo bioluminescence imaging of gene expression
    Contag, CH
    Bachmann, MH
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2002, 4 : 235 - 260
  • [6] A quantitative study of factors affecting in vivo bioluminescence imaging
    Cui, Kemi
    Xu, Xiaoyin
    Zhao, Hong
    Wong, Stephen T. C.
    LUMINESCENCE, 2008, 23 (05) : 292 - 295
  • [7] Noninvasive Monitoring of Placenta-Specific Transgene Expression by Bioluminescence Imaging
    Fan, Xiujun
    Ren, Peigen
    Dhal, Sabita
    Bejerano, Gill
    Goodman, Stuart B.
    Druzin, Maurice L.
    Gambhir, Sanjiv S.
    Nayak, Nihar R.
    PLOS ONE, 2011, 6 (01):
  • [8] In vivo magnetic resonance imaging of transgene expression
    Weissleder R.
    Moore A.
    Mahmood U.
    Bhorade R.
    Benveniste H.
    Chiocca E.A.
    Basilion J.P.
    Nature Medicine, 2000, 6 (3) : 351 - 354
  • [9] In vivo quantitative noninvasive bioluminescence imaging of intraportal transplanted islets
    Contreras, JL
    Chaudhuri, TR
    Starged, AS
    Wu, HJ
    Smyth, CA
    Bilbao, G
    Curiel, DT
    Eckhoff, D
    Zinn, KR
    AMERICAN JOURNAL OF TRANSPLANTATION, 2004, 4 : 467 - 467
  • [10] In vivo bioluminescence imaging
    Sato, A
    Klaunberg, B
    Tolwani, R
    COMPARATIVE MEDICINE, 2004, 54 (06) : 631 - 634