U-shaped, double-tapered, fiber-optic sensor for effective biofilm growth monitoring

被引:55
|
作者
Zhong, Nianbing [1 ]
Zhao, Mingfu [1 ]
Li, Yishan [2 ]
机构
[1] Chongqing Univ Technol, Chongqing Key Lab Modern Photoelect Detect Techno, Chongqing 400054, Peoples R China
[2] Chongqing Univ, Minist Educ, Key Lab Low Grade Energy Utilizat Technol & Syst, Chongqing 400030, Peoples R China
来源
BIOMEDICAL OPTICS EXPRESS | 2016年 / 7卷 / 02期
基金
中国国家自然科学基金;
关键词
HYDROGEN-PRODUCTION; REFRACTIVE-INDEX; PHOTOBIOREACTOR; FABRICATION; ACCUMULATION; SPECTROSCOPY; TEMPERATURE; PERFORMANCE; MICROSCOPY; MECHANISM;
D O I
10.1364/BOE.7.000352
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To monitor biofilm growth on polydimethylsiloxane in a photobioreactor effectively, the biofilm cells and liquids were separated and measured using a sensor with two U-shaped, double-tapered, fiber-optic probes (Sen. and Ref. probes). The probes' Au-coated hemispherical tips enabled double-pass evanescent field absorption. The Sen. probe sensed the cells and liquids inside the biofilm. The polyimide-silica hybrid-film-coated Ref. probe separated the liquids from the biofilm cells and analyzed the liquid concentration. The biofilm structure and active biomass were also examined to confirm the effectiveness of the measurement using a simulation model. The sensor was found to effectively respond to the biofilm growth in the adsorption through exponential phases at thicknesses of 0-536 mu m. (C) 2016 Optical Society of America
引用
收藏
页码:352 / 368
页数:17
相关论文
共 50 条
  • [1] U-shaped fiber-optic ATR sensor enhanced by silver nanoparticles for continuous glucose monitoring
    Li, Dachao
    Yu, Songlin
    Sun, Changyue
    Zou, Chongwei
    Yu, Haixia
    Xu, Kexin
    BIOSENSORS & BIOELECTRONICS, 2015, 72 : 370 - 375
  • [2] Performance improvement of sapphire fiber-optic sensor using a U-shaped reference fiber
    Tong, LM
    Shen, YH
    Ye, LH
    Chen, L
    OPTICAL AND FIBER OPTIC SENSOR SYSTEMS, 1998, 3555 : 236 - 243
  • [3] Remote monitoring of water salinity by using side-polished fiber-optic U-shaped sensor
    Stupar, Dragan Z.
    Bajic, Jovan S.
    Joza, Ana V.
    Dakic, Bojan M.
    Slankamenac, Milos P.
    Zivanov, Milos B.
    Cibula, Edvard
    2012 15TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE/PEMC), 2012,
  • [4] Fabrication and characterization of U-shaped fiber-optic pH probes
    Gupta, BD
    Sharma, NK
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 82 (01) : 89 - 93
  • [5] A Fiber-Optic Sensor for Accurately Monitoring Biofilm Growth in a Hydrogen Production Photobioreactor
    Zhong, Nianbing
    Liao, Qiang
    Zhu, Xun
    Chen, Rong
    ANALYTICAL CHEMISTRY, 2014, 86 (08) : 3994 - 4001
  • [6] Noncontact Optical Displacement Sensor Using an Adiabatic U-Shaped Tapered Fiber
    Ab Razak, Mohd Zulhakimi
    Reduan, Siti Aisyah
    Sharbirin, Anir Syazwan
    Jamaludin, Norsyazriza
    Zulkifli, Mohd Zamani
    Ahmad, Harith
    IEEE SENSORS JOURNAL, 2015, 15 (10) : 5388 - 5392
  • [7] U-shaped fiber optic lossy mode resonance sensor for the detection of antibiotics
    Vikas
    Saccomandi, Paola
    2023 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR LIVING ENVIRONMENT, METROLIVENV, 2023, : 50 - 54
  • [8] Tapered Fiber Bioprobe Based on U-Shaped Fiber Transmission for Immunoassay
    Chen, Xinghong
    Xiao, Lei
    Li, Xuejin
    Yi, Duo
    Zhang, Jinghan
    Yuan, Hao
    Ning, Zhiyao
    Hong, Xueming
    Chen, Yuzhi
    BIOSENSORS-BASEL, 2023, 13 (10):
  • [9] Monitoring Microalgal Biofilm Growth and Phenol Degradation with Fiber-Optic Sensors
    Zhong, Nianbing
    Wu, Yongwu
    Wang, Zhengkun
    Chang, Haixing
    Zhong, Dengjie
    Xu, Yunlan
    Hu, Xinyu
    Huang, Liwen
    ANALYTICAL CHEMISTRY, 2019, 91 (23) : 15155 - 15162
  • [10] A novel fiber-optic tapered long-period grating sensor for pressure monitoring
    Bock, Wojtek J.
    Chen, Jiahua
    Mikulic, Predrag
    Eftimov, Tinko
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (04) : 1176 - 1180